11
EN
TECHNICAL SPECIFICATIONS
Dexxo Pro 800 RTS
Dexxo Pro 1000 RTS
BASIC TECHNICAL CHARACTERISTICS
Mains supply
230 V - 50 Hz
Max. power consumption
Standby-Operation
5 W - 600 W (with 500 W remote lighting)
Traction force
Peak force
Starting force (1)
800 N
650 N
1000 N
800 N
Use
Number of Opening/Closing cycles per day
20 cycles max. per day with a standard rail - 50 cycles max. per day with a high performance rail tested
for 36,500 cycles with a standard rail and 90,000 cycles with a high performance rail
Max. speed
18 cm/s
Programming interface
7 buttons - 2 character LCD display
Operating temperature
- 20 ° C / + 60 ° C - indoor dry - IP 20
Travel end limits
Mechanical stopper at opening
Memorized end limit position at closing
Electrical insulation
Class 2: double insulation
Built in lighting
24 V / 21 W ; BA15s socket
Somfy radio frequency
RTS 433.42 MHz
Number of channels that can be memorised
32
CONNECTIONS
Safety input
Type
Compatibility
Dry contact: NC
Photoelectric TX/RX cells - Reflex cell - Sensor strip with dry contact output
Pedestrian door safety input
Dry contact: NC
Wired control input
Dry contact: NO
Remote lighting output
230 V - 500 W - class 2
Orange light output
24 V - 15 W with built in flashing control
24 V controlled power supply output
Yes: for possible photoelectric TX/RX cell self-test
Safety input test output
Yes: for possible reflex cell or sensor strip self-test
Accessory power supply output
24 V - 500 mA max
Remote aerial input
Yes: RTS aerial compatible (Réf. 2400472)
Backup battery input
Autonomy
Yes: battery pack compatible (Réf. 9001001)
24 hours; 5 to 10 cycles depending on door
Charge time: 48 hours
OPERATION
Forced operation mode
By pressing and holding the motor control button
Independent lighting control
Yes for remote lighting
Lighting time delay (after movement)
Programmable : 60 s to 600 s
Automatic closing mode
Yes: programmable closing time delay from 10 to 120 s
Orange light pre-warning
Programmable: with or without prior warning (duration set to 2 s)
Safety input operation
While closing
Before opening
(Dangerous Movement Area Accessible
to the Public)
Programmable: Stop - Partial re-opening - Full reopening
Programmable: no effect or motion refused
Built-in obstacle detection
Adjustable sensitivity: 4 levels
Operation when an obstacle is detected
Programmable : partial re-opening or full reopening
Preset partial opening command
Yes can be selected: adjustable partial opening position
Progressive start up
Yes
Opening speed
Programmable from 3.5 cm/s to 18 cm/s: 10 possible values
Closing speed
Programmable from 3.5 cm/s to 18 cm/s: 10 possible values
Closure approach speed
Programmable: does not slow down, short slowdown zone (30 cm),
long slowdown zone (50 cm)
Troubleshooting
Recording and accessing data: Cycle counter, cycle counter with obstacle detection, number of radio
channels stored, history of the last ten defects recorded.
(1) Maximum load for motor to start and drive door for at least 5 cm (according to RAL-GZ definition).
Dimensions
171 min
63.6
140
125
Available travel: 2,555 / 3,155
Overall length: 3,295 / 3,895
Overall length: 3,153 / 3,753
65.5
224.4
224.4
Fixation: 2,982 / 3,582
Rail: 2,900 / 3,500
Rail : 2,900 / 3,500
33.5
130.9
404.2
404.2
106
313.6
254.1
139.5
164.4
150.1
112.2