Dexxo Optimo RTS
Copyright © 2017 Somfy SAS. All rights reserved
3
EN
1.6 Regulations
Somfy SAS declares that the product described in these
instructions, when used in accordance with these instructions,
complies with the essential requirements of the applicable
European Directives and, in particular, with Machinery Directive
2006/42/EC and the Radio Equipment Directive 2014/53/EU.
The full text of the EC declaration of conformity is
available on the following website: www.somfy.com/ce.
Antoine CREZE, Head of Regulations, Cluses
1.7 Assistance
You may encounter difficulties or have questions when installing your
motorisation.
Do not hesitate to contact us; our specialists are on hand to answer all
your questions. Internet: www.somfy.com
1.8 Danger zones
WARNING
Risk prevention - motorisation of sectional/up and over
garage door for residential usage
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 4
Zone 1
Zone 2
Zone 3
Zone 5
Zone 4
>
Risk zones: measures to be taken to eliminate risks
RISK
SOLUTION
ZONE 1
Risk of crushing between
the ground and the lower
edge of the door during
closing
Obstacle detection built into the
motorisation. It must be imperatively
checked that the obstacle detection
complies with annex A of the standard
EN 12 453.
For operation with automatic closing,
install photoelectric cells (see
installation manual)
ZONE 2
Risk of crushing between
the lintel and the upper
edge of the door during
closing
Obstacle detection built into the
motorisation. It must be imperatively
checked that the obstacle detection
complies with annex A of the standard
EN 12 453.
ZONE 3
Risk of cutting or trapping
between the door panels in
gaps of between 8mm and
25mm
Eliminate all sticking points and all
sharp edges from the surface of the
door
Eliminate any gap ≥ 8 mm or ≤ 25 mm
ZONE 4
Risk of trapping between
the roller rails and
bearings
Eliminate all sharp edges on the guide
rails
Eliminate any gap ≥ 8 mm between the
rails and the bearings
ZONE 5
Risk of crushing between
the secondary edges and
adjoining fixed parts
Obstacle detection built into the
motorisation. It must be imperatively
checked that the obstacle detection
complies with annex A of the standard
EN 12 453.
WARNING
Risk prevention - motorisation of sliding garage door for
residential usage
>
Zone 1
Zone 2
Zone 3
Zone 4
Zone 4
Risk zones: measures to be taken to eliminate risks.
RISK
SOLUTION
ZONE 1
Risk of crushing during
closing
Obstacle detection built into the
motorisation. It must be imperatively
checked that the obstacle detection
complies with annex A of the standard
EN 12 453.
For operation with automatic closing,
install photoelectric cells (see
installation manual)
ZONE 2
Risk of crushing with an
adjoining fixed part
Obstacle detection built into the
motorisation. It must be imperatively
checked that the obstacle detection
complies with annex A of the standard
EN 12 453.
Mechanical protection (see figure 1) or
via safety distances (see figure 2)
ZONE 3
Risk of cutting or trapping
between the door panels in
gaps of between 8mm and
25mm
Eliminate all sticking points and all
sharp edges from the surface of the
door
Eliminate any gap ≥ 8 mm or ≤ 25 mm