A

  INSTALLATION

 

[1]    

Choisir le meilleur emplacement:  
surface plane et spacieuse

 

[2]  

 Fixer le Motor Controller 4 DC 2 A WM

 

[3]   

Connecter l‘alimentation et les fils électriques 
au Motor Controller

 

 

 

B

  CÂBLAGE

 

[1]  

  Tournevis isolé

 

[2]  

Schéma de câblage

 

[3]  

  Contrôle de la direction de fonctionnement des 
produits porteurs

 

 

MONTÉE: le produit porteur monte 

( C +

s

)

 

 

ARRÊT: le produit porteur s‘arrête 

(

 

C +

t

+

s

)

 

 

  DESCENTE: le produit porteur descend 

( C +

t

)

 

[4]  

    Boutons poussoirs

 

 

 1.

 

Inteo Centralis IB, Ref. 1810138

 

 

2. 

  Bouton double

C

  CONFIGURATION

 

[1] 

   Reset / Prog bouton

Ce bouton permet d’accéder à la configuration 
basique de l‘automatisme.

  

 La LED "US" clignote quand l‘alimentation principale 
(24 V) et l‘alimentation du bus KNX sont connectées au 
produit. Le produit est alors prêt pour une utilisation 
normale. Le bouton Reset / Prog peut être utilisé pour 
sélectionner l‘ergonomie quand le produit est en mode 
par défaut et n‘a jamais été programmé depuis le  
software ETS. Les differentes possibilités d‘ergonomies 
sont décrites dans le manuel utilisateur.

 

[2] 

   

Sélection de l‘ergonomie des boutons poussoirs

Ergonomie des boutons poussoirs et type de 
produits porteurs à sélectionner:

 

 

    • Mode screen (store rouleaux) 

• Store vénitien et mode "Europe" 
 • Store vénitien et mode "US" 
Mode par défaut: store vénitien avec ergonomie 
mode "EU".

 

 

 

1.

  

Pour changer de mode, donner une impulsion 
sur le bouton Reset / Prog. Répéter l‘opération 
jusqu‘à avoir la bonne LED allumée.  
(Se référer au manuel pour la LED.)

 

[3] 

   

Retour configuration usine

 

[4] 

   

Acquisition du temps de fonctionnement 
et de rotation/course

 

 

 

1.  

Appuyer immédiatement quand la butée 
basse est atteinte

 

 

 

2. 

  Maintenir stop appuyé pendant toute la durée 
de rotation

 

[5] 

  Symboles:  les actions 

 

 

  

1.

 

Montée

 

 

2. 

   Arrêt

 

[6] 

Symboles: état du produit porteur

 

 

    

1.

 

Montée

 

2.

 

Position haute

3.

 

Descente

4.

 

Position basse

A

  MOUNTING

 

[1]  

Choose the optimal location: flat and large surface

 

[2]  

Mount the 4 DC 2 A Motor Controller WM

 

[3] 

  Connect power supply and wiring to the 
Motor Controller

 

 

  

B

  WIRING

 

[1]  

Insulated screwdriver

 

[2]  

Wiring diagram

 

[3]  

  Check the correct running directions of the 
end product

 

 

UP: the end product goes up

 ( C +

s

)

 

 

STOP: the end product stops 

( C +

t

+

s

)

 

 

DOWN: the end product goes down 

( C +

t

)

 

[4]  

  Possible switches

 

 

 1.

 

Inteo Centralis IB, Ref. 1810138

 

 

2. 

  Double push button

 

C

  CONFIGURATION

 

[1] 

   

Reset / Prog button

With this button, you can access the basic  
configuration of the Motor Controller.

 

 The "US" LED is steadily blinking when the mains (24 V) 
and the KNX bus power are actively connected to the  
device. The device is ready for operation when the  
"US" LED is blinking. The Reset / Prog button can be 
used to select a switch ergonomic when the device is 
in default condition and is not programmed by the ETS 
Software. The different ergonomics are described in the 
user manual.

 

[2] 

    

Selection of switch ergonomic

Local push button ergonomics and the type of end 
products to be preselected:

 

 

    • Screen mode 

• Venetian blind, European mode 
 • Venetian blind, US mode 
The default mode is: venetian blind, EU mode. 

1.

  

To toggle between modes, press shortly the 
Reset / Prog button. Repeat until the LED,  
according to the desired configuration, lights up.

 

[3] 

 

 Factory RESET

 

[4] 

 

 Learn running and tilting times/length

 

 

 

1.  

Press immediately when lower end limit 
is reached

 

 

 

2. 

Maintain stop for duration of tilting

 

[5] 

  Symbols: actions

 

 

  

1.

 

Up

 

 

2. 

  Stop

 

[6] 

Symbols: end product status

 

 

    

1.

 

Up

 

2.

 

High position

3.

 

Down

4.

 

Low position

110331_animeo KNX_4DC 2A_Moco_shortint.indd   7

31.03.11   15:00

Содержание animeo KNX 4 DC 2 A

Страница 1: ...g elektriker SOMFY s taganden g ller ej om installation inte utf rts enligt instruktionerna Spara manualen f r framtida bruk Vor Inbetriebnahme unbedingt die Sicherheits anwei sungen in dieser Anleitu...

Страница 2: ...www somfy co il Tel 972 0 39 525 554 ITALY SOMFY Italia S R L www somfy it Tel 39 0 24 847 181 JAPAN SOMFY K K www somfy co jp Tel 81 0 454 750 732 KOREA SOMFY JOO www somfy co kr Tel 82 0 316 005 250...

Страница 3: ...Installationsvejledning Asennusohjeet Notice d installation Installation guide Guida all installazione Montagehandleiding Installasjonsanvisninger Innstallationsanvisningar KNX 4 DC 2 A Motor Control...

Страница 4: ...animeo KNX 4 DC 2 A MOTOR CONTROLLER REF 5057402 B 2 12 A 3 63 mm 140 mm min 120 mm 1 2 1 2 Notes Bus Mains Bus 10 cm Mains 110331_animeo KNX_4DC 2A_Moco_shortint indd 2 31 03 11 15 00...

Страница 5: ...m2 max 20 m 2 1 2 M1 Motor 2 1 2 1 2 M2 Motor 3 1 2 1 2 M3 each J Y St Y 2x2x0 8 mm2 max 50 m C 1 A B Local push button Motor 1 com binary input A binary input B C 4 G H Local push button Motor 4 com...

Страница 6: ...Reset Prog Reset Prog Reset Prog Reset Prog SCR EU US Reset Prog SCR EU US Reset Prog SCR EU US Reset Prog SCR EU US Reset Prog SCR EU US 1 10 s Reset Prog SCR EU US Reset Prog SCR EU US Reset Prog S...

Страница 7: ...en bis die gew nschte LED leuchtet 3 Komplett RESET 4 Lauf und Wendezeit L nge einlernen 1 Sofort dr cken wenn untere Endlage erreicht ist 2 Stopp halten w hrend der kompletten Wendung 5 Symbole Bedie...

Страница 8: ...m2 13 AWG Recommended 150 m Group control Min 3 x 0 6 mm2 19 AWG Max 3 x 1 5 mm2 13 AWG Recommended 1000 m KNX bus 2 x 2 x 0 8 mm2 Required following KNX topology guidelines 1000 m 24 V DC Min 3 x 0 7...

Страница 9: ...YL S tuotteen tulee menn yl s C s SEIS tuotteen tulee pys hty C t s ALAS tuotteen tulee menn alas C t 4 Mahdolliset kytkimet 1 Inteo Centralis IB Ref 1810138 2 Kytkimet C ASETUKSET 1 Reset Prog paini...

Страница 10: ...configuration usine 4 Acquisition du temps de fonctionnement et de rotation course 1 Appuyer imm diatement quand la but e basse est atteinte 2 Maintenir stop appuy pendant toute la dur e de rotation...

Страница 11: ...acciavite isolato 2 Schema di cablaggio 3 Controllare il corretto senso di movimento del prodotto portante SALITA il prodotto portante sale C s STOP il prodotto portante si arresta C t s DISCESA il pr...

Страница 12: ...produkt 1 Opp 2 Kj rt helt inn 3 Ned 4 Kj rt helt ut Om du ikke bruker Somfy motorer f lg v r generelle informasjon i v r instalasjonsguide www somfy com A MONTAGE 1 Kies de juiste plaats vlakke onder...

Отзывы: