Remote units only
There are a few fundamental differences between the close couple units.
Electrical
1. The control power comes from the extractor panel; this panel
must be on for the system to work.
2. Interconnecting wires must be connected to correct terminals
(dash lines on FE print).
Plumbing
1. The elimination of the overflow assembly at the pulper. Balance of
the system is done in a normal Somat fashion (at the extractor).
On one on one units the throttling valve will be
located near the extractor in the return line adjust valve while
monitoring amps of the return pump motor.
On multiple units the throttling valve will be located near pulpers in
the return line adjust to obtain good trough flow and the desired
overflow at extractor.
(Special attention to not over amping motors)
Pressure switch
These units will have a dual switch in them. The left side is for
setting the “flood” level, this is controlling the operation of the
MOV stopping water flow in the return line if pulper is to full.
The right side is your normal prefill/operating water level setting
(approx 1” above security ring).