background image

21 

 

3.  Normal Use 

Lighting

:  

 

 

a) Place firewood of the correct size (mentioned above) in the unit, piled 

horizontally; 

 

b) Place some pine cones (preferably) on the ash grate;  

 

c)  If  required  to  make  lighting  easier,  open  the  air  regulator  completely 

to allow the inflow of combustion air and then regulate the burn intensity; 

 

d) The lighting period is over when the body of the stove has reached a 

constant temperature.  

 

* You should check that there is sufficient ventilation in the room where the unit 

is installed, otherwise it will not work properly. For this reason, you should check 

if there are any other heating devices which consume air during operation (e.g. 

gas-fired equipment, braziers, etc). We recommend against using these devices 

all at once;  

 

*  The  air  for  combustion  is  drawn  from  the  surrounding  room,  consuming 

oxygen.  You should check that ventilation grilles and  other devices for allowing 

air to enter from outside remain unobstructed; 

 

 *  You  should  only  open  the  door  during  reloading.  Normal  conditions  of  use 

require the door to remain closed;  

Содержание Trevi 1100

Страница 1: ...1 Instruction Manual English Insert Fires Panoramic Line Trevi 850 Trevi 1100 Mod 168 E ...

Страница 2: ...l are not followed All local regulations including those referring to national and European standards should be complied with when installing the unit Our Panoramic Line Insert Fires have been tested according to standards EN 13229 2001 EN 13229 2001 AC 2003 EN 13229 2001 A1 2003 EN 13229 2001 A2 2004 EN 13229 2001 AC 2006 EN 13229 2001 A2 2004 AC 2006 Technical support is normally provided by SOL...

Страница 3: ...3 Contents Solzaima 4 Technical Specifications 5 Your Stove 7 Components 9 Installation 10 Instructions for Use 16 Troubleshooting 25 End of Life 26 Sustainability 26 Glossary 27 Warranty 29 ...

Страница 4: ...y a leading player in the production of biomass heating solutions best illustrated by our backboiler fires for central heating We provide annually approximately 20000 homes with biomass heating solutions This market has been growing at an annual rate of 20 a sign that consumers are becoming increasingly aware of ecological and more cost effective heating solutions Solzaima is the only manufacturer...

Страница 5: ...ting a high efficiency rate and considerable firewood savings such is the case of the new designer devices with a guillotine door TREVI 850 and TREVI 1100 Technical specifications across this range CE certified Frequency 50 Hz Power 66 W With optional ventilation Voltage 230 V Maximum fuel load 11pounds 6 7 Kg Average reloading time 45 minutes Type of equipment intermittent use Fuel Dry firewood ...

Страница 6: ...ches mm 40 1 1020 41 5 1055 50 1270 41 5 1055 Total Depth inches mm 21 2 540 21 2 540 Flue Ø inches mm Ø 7 8 200 int Ø 9 8 250 int Rated output kW 21 7 21 7 Efficiency 77 77 CO Emissions 13 O2 0 88 0 88 CO2 Emissions 12 3 12 3 Average combustion temperature ºF ºC 351 351 Combustion flow g s 14 14 Power output1 kW 15 2 28 2 15 2 28 2 Firewood consumption2 pounds kg h 10 3 4 7 19 1 8 7 10 3 4 7 19 1...

Страница 7: ...7 Your Stove Trevi 850 Trevi 1100 Fig 1 Trevi 850 and Trevi 1100 with and without frame TREVI 850 TREVI 850 with frame optional TREVI 1100 TREVI 1100 with frame optional ...

Страница 8: ...c line unit Smoke outlet Hot air outlets Air intakes Ash pan Counterweight blocking screws Combustion air intake regulation damper Adjustable legs Door lock for cleaning Vermiculite panels Latch for opening the door Combustion air intake openings ...

Страница 9: ...silicate that can withstand temperatures in the order of 2012 F 1100 C Its insulating properties allow the unit to take better advantage of the heat increasing the temperature inside the chamber and enabling cleaner combustion lower CO content as well as providing greater protection for the steel plate forming the combustion chamber walls and thus prolonging the life of the equipment The specially...

Страница 10: ...e following a Before assembly remove the counterweight blocking screws that ensure the stove can be transported safely Fig 3 b Open the hot air outlets located on the top of the unit Fig 4 Fig 3 Fig 4 c Check that all parts are functioning correctly before installation d Raise and lower the door using the key provided Figs 5 and 6 Fig 5 Fig 6 e Open the door to the front in cleaning mode using the...

Страница 11: ...w should be kept clear at all times Additional air inlets may be needed if the stove is used in simultaneous with other devices that require an air supply The installer should evaluate the situation according to the overall air flow requirements Under normal operating conditions the combustion gas flow should create a draught of 12 Pa one metre above the throat of the flue For proper installation ...

Страница 12: ...n and be placed at least 23 6 inches 60cm above the top of any obstacle located within a distance of 9 8 feet 3m Brick chimneys should not be too wide as the smoke will cool as it disperses reducing the draft In case of draft problems a revolving chimney cowl can be installed The same flue should not be used for more than one unit or open fireplace With shared chimneys each flue should reach its o...

Страница 13: ...ot be installed close to the walls of the stoves in the installation area or in the air convection area Materials objects placed in front of the stoves should be able to withstand the heat radiated from the glass of the door so should not be combustible The floor on which the unit will stand must be able to support a permanent load of 2 2 pounds 1kg cm If the load capacity of the floor is insuffic...

Страница 14: ...tones or any other type of finishing to allow room for the metal to expand The housing whether it is stone plasterboard or any other material should also allow the stove to be removed without causing damage if the need arises The use of wood finishing may increase the risk of fire Therefore we recommend the use of adequate insulation or that wood not be used at all ...

Страница 15: ...ral and live should be connected We take no responsibility for any damage resulting from non compliance with this warning The electrical components should always be connected to the power supply The cable used for the electrical connection should be silicon coated and heat resistant to 356 F 180 C If the power feed cable is damaged it should only be replaced by a qualified technician Controller Co...

Страница 16: ...type of unit It may not be used as an incinerator nor should other materials such as coal painted wood varnishes thinners liquid fuels glues or plastics be used Also avoid burning common combustible materials such as cardboard and straw The firewood should have a low water content less than 20 in order to ensure efficient combustion and avoid creosote build up in the smoke duct and on the glass Se...

Страница 17: ... lar Difficult Slow Hard Holm Oak Quercus ilex Southern Europe Little Very High Difficult Slow Hard Olive tree Olea Mediterranean Region Little Very High Difficult Slow Hard Oak Quercus Across Europe Little High Difficult Slow Hard Ash Fraxinus Across Europe Regula r High Difficult Slow Hard Birch Betula Across Europe Little Very High Easy Fast Soft Beech Fagus Europe except Iberian Peninsula and ...

Страница 18: ...easonable operation range This power output range will present different firewood consumptions per hour 1 2 Energy Efficiency and Performance Ratings Implementing solutions that seek to achieve greater energy efficiency allows for substantial reductions in energy needs and thus reduces our current dependence on fossil fuels and other non renewable sources of energy Energy efficiency enables you to...

Страница 19: ...Solzaima 5kW unit with an efficiency rate of 75 i e efficiency class 1 will consume approximately 3 5 pounds 1 6kg of firewood per hour to warm a 389 sq ft room 35m2 Typically a traditional fireplace has an efficiency rate of approximately 10 which means it will consume about 26 5 pounds 12kg of firewood to produce the same 5kw necessary to warm the same 389 sq ft room 35m2 EFFICIENCY RATING EFFIC...

Страница 20: ...8 8 pounds 4kg of firewood A fire with an efficiency rate of 50 class 3 consumes 5 3 pounds 2 4kg of firewood A Solzaima fire with an efficiency rate of 75 class 1 consumes only 3 5 pounds 1 6kg of firewood 2 First Use Ask the installer to light the unit to ensure that all is functioning correctly The stove s paint is cured by the heat when it is first used which may give rise to additional smoke ...

Страница 21: ...heck that there is sufficient ventilation in the room where the unit is installed otherwise it will not work properly For this reason you should check if there are any other heating devices which consume air during operation e g gas fired equipment braziers etc We recommend against using these devices all at once The air for combustion is drawn from the surrounding room consuming oxygen You should...

Страница 22: ...legs so you can install your unit at the height you desire 5 Hot air outlets There are 4 hot air outlets on the stove s top panel Each measures 5 1 inches 130mm in diameter and should be used to channel the hot air into the room where the stove is installed or to other rooms If the warm air duct always runs upwards there is no need for a forced system If it is for distributing the heat you should ...

Страница 23: ...temperatures above 113ºF 45 C Do not touch the hotter areas You should use a glove or other protection if you have to touch the unit when it is in operation The electrical components should always be connected to the power supply where applicable In case of fire in the flue immediately close the door of the unit and the air intake regulator If there is a power cut resulting in the ventilators cutt...

Страница 24: ...mpletely cold The glass should be cleaned with a suitable product 4 by following the instructions for use and not allowing the product to come into contact with the sealing string and painted metal parts which could initiate oxidation The sealing string is glued so should not be moistened with water or cleaning products If it becomes detached it can be reattached with contact glue after cleaning t...

Страница 25: ...ons Clean the flue There may be exceptional weather conditions Weak fire Check moisture of firewood and opening of the combustion air intake regulator Check entry of air into the room Ventilation stopped working Check possible obstruction of ventilator Check and or reconnect power supply The stovemay not be hot enough to make the ventilator switch on Ventilation working but flow is weak Clean all ...

Страница 26: ...a designs solutions and equipment moved by biomass as their primary energy source This is our contribution for the sustainability of our planet an economically viable and environmentally friendly alternative following environmental best management practices to ensure an efficient carbon cycle management Solzaima cares about being up to date with and assessing the existing forest area while efficie...

Страница 27: ...hemical reaction that requires three things in order to take place fuel oxidant and ignition temperature Oxidant chemical substance that feeds combustion essentially oxygen and is essential for it to take place Fuel anything that can undergo combustion in this case wood Creosote chemical compound created by combustion This compound is sometimes deposited on the glass and flue of an insert fire Cir...

Страница 28: ...al heat output heating capacity i e the heat energy the unit transfers from energy present in the firewood measured for a standard load of firewood over a given period of time Power output a manufacturer s recommendation from tests on the equipment with firewood loads within a reasonable operating range This power output range will present different firewood consumptions per hour Plumb vertically ...

Страница 29: ...82 F 750 C in constant operation as well as temperature peaks of 1562 F 850 C temperatures which are never reached during normal operation The type of fuel used and how the unit is handled are not within SOLZAIMA s control so the parts in direct contact with the flame the ash grate comb and baffle plate are not covered by this warranty The vermiculite and sealing ring are not included in the warra...

Страница 30: ...30 Please read this Instruction Manual carefully and keep it for future reference All Solzaima products come with a 2 year warranty APPROVED PRODUCT ...

Отзывы: