In any case a bi-polar DC-switch has to be installed. If it is not integrated in the
inverter, this switch has to be installed as a separated part. The switch has to make
sure the galvanic separation.
5. Instruction for installation
The following reference notes are to be adhered during the installation on location:
During work on roof all accident prevention regulations have to be respected. It is
recommended to protect all uninvolved people nearby. A scaffold should be installed
during work.
During installation make sure not to strain the modules.
If lengthening
of string wiring is necessary the polarity has to be respected.
The modules have to be mounted in a way which prevents rain water penetrating into
the plugs.