Solution Splendor 90 CM-90 Скачать руководство пользователя страница 3

 13A 

1.  If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin 

adapter-cable. 

2.  At last unit, the DMX cable has to be terminated with a terminator. Solder a 

120 ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin 

XLR-plug and plug it in the DMX-output of the last unit. 

3.  Connect the unit together in a `daisy chain` by XLR plug from the output of the 

unit to the input of the next unit. The cable can not branched or split to a `Y` 

cable. DMX 512 is a very high-speed signal. Inadequate or damaged cables, 

soldered joints or corroded connectors can easily distort the signal and shut 

down the system. 

4.  The DMX output and input connectors are pass-through to maintain the DMX 

circuit, when power is disconnected to the unit. 

5.  Each lighting unit needs to have an address set to receive the data sent by the 

controller. The address number is between 0-511 (usually 0 & 1 are equal to 

1). 

6.  The end of the DMX 512 system should be terminated to reduce signal errors. 

7.  3 pin XLR connectors are more popular than 5 pin XLR. 

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

          Pin 4/5: Not used. 

 

 

 6. Troubleshooting  

Following are a few common problems that may occur during operation. Here are 

some suggestions for easy troubleshooting: 

A.  The unit does not work, no light and the fan does not work 

1.  Check the connection of power and main fuse. 

2.  Measure the mains voltage on the main connector. 

3.  Check the power on LED. 

B.  Not responding to DMX controller 

1.  DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.  If the DMX LED is on and no response to the channel, check the address settings and           

DMX polarity. 

3.  If you have intermittent DMX signal problems, check the pins on connectors or on PCB 

 2A

  1. Safety Instruction 

 

 

 

WARNING

 

y

  Please keep this User Guide for future consultation. If you sell the unit to another user, be 

sure that they also receive this instruction booklet. 

y

  Unpack and check carefully there is no transportation damage before using the unit. 

y

  Before operating, ensure that the voltage and frequency of power supply match the power 

requirements of the unit.   

y

 It’s important to ground the yellow/green conductor to earth in order to avoid electric 

shock. 

y

  The unit is for indoor use only. Use only in a dry location. 

y

 The unit must be installed in a location with adequate ventilation, at least 50cm from 

adjacent surfaces. Be sure that no ventilation slots are blocked.   

y

  Disconnect main power before replacement or servicing.   

y

  Make sure there is no flammable materials close to the unit while operating as it is fire 

hazard.  

y

  Use safety cable when fixes this unit.   

y

  Maximum ambient temperature is TA: 40

. Don’t operate it where the temperature is 

higher than this. 

y

  In the event of serious operating problem, stop using the unit immediately. Never try to 

repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or 

malfunction. Please contact the nearest authorized technical assistance center. Always 

use the same type spare parts. 

y

  Do not touch any wire during operation as high voltage might be causing electric shock. 

 

Warning 

y

  To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or 

moisture. 

y

  Do not open the unit within five minutes after switching off. 

y

  The housing, the lenses must be replaced if they are visibly damaged. 

 

Please read carefully the instruction, which includes important 

information about the installation, usage and maintenance. 

Содержание Splendor 90 CM-90

Страница 1: ...lity EMC Directive 89 336 EEC EN55103 1 199601 2 EN55103 2 1996 EN61000 3 2 2000 A2 2005 EN61000 3 3 1995 A1 2001 A2 2005 Harmonized Standard EN 60598 1 2004 IEC 60598 1 2003 corrigendum 2004 Part 1 G...

Страница 2: ...ng 2 Check the LED for the response of the master slave mode signal D No response to the sound 1 Make sure the unit does not receive DMX signal 2 Check if the sound sensitively is too low E One of the...

Страница 3: ...nel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB 2A 1 Safety Instruction WARNING y Please keep this User Guide for...

Страница 4: ...support a 10 times weight of the unit 2 Technical Specification y DMX Channels 16 9 channels y Great built in lighting shows under Master Slave mode triggered by music y Through its flexible installat...

Страница 5: ...e press the MENU button or wait for 8 seconds Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel Mode Unit 1 Unit 2 Unit 3 Unit 4 9 channels 1 10 19 28...

Страница 6: ...5 How To Control The Unit You can operate the unit in three ways 1 By master slave built in preprogram function 2 By easy controller 3 By universal DMX controller 5 1 Master Slave Built in Preprogram...

Страница 7: ...out any change press the MENU button or wait for 8 seconds Fixture Time Press the MENU button up to when the Fixture Time is blinking on the display Pressing ENTER button and the display will show the...

Страница 8: ...Out is showing on the display Pressing 8A ENTER button and the display will blink Use DOWN and UP button to select the yes yes blackout or no no blackout mode Once selected press the ENTER button to...

Отзывы: