Check circuit fuses or breakers.
Check all electrical connections to insure proper
contact.
CAUTION:
Make sure the main power if OFF when checking any
electrical connection.
11
1. Fan will not start:
Make sure all motor housing screws are sung.
Make sure the screws that attach the fan blade brackets to the motor are tight.
Make sure wire nut connections are not rubbing against each other or the
interior wall of the switch housing.
CAUTION:
Make sure main power is off.
Allow a 24-hour "breaking-in" period. Most noise associated with a new fan
disappear during this time.
If using an optional light kit, make sure the screws securing the glassware are
tight. Make sure the light bulbs are not touchingany other component.
2. Fan sounds noisy:
Check that all blade and blade arm screws are secure.
Most fan wobbling problems are caused by blade levels unequal. Check this
level by selecting a point on the ceiling above the tip of one of the blades.
Measure this distance. Rotate the fan until the next blade is positioned for
measurement. Repeat for each blade. This distance deviation should be
equal within 1/8".
Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable.
If the blade wobble is still noticeable, interchanging two adjacent ( side by
side) blades can reditribute the weight and possibly result in smoother
operation.
3. Fan wobble:
1.