II

Identify your tanning device

For contact with customer service, please write down the device number of your tanning device.

Global Service Division

#1 Walter Kratz Drive
Jonesboro, Arkansas 72401

(

 (800) 445 0624

04196 / 0

 III

Содержание S-40 Champ *** Super

Страница 1: ...Soltron 801233 Index b us 01 2004 Operating Instructions 04173 0 S 40 Champ Super...

Страница 2: ...y your tanning device For contact with customer service please write down the device number of your tanning device Global Service Division 1 Walter Kratz Drive Jonesboro Arkansas 72401 800 445 0624 04...

Страница 3: ...III This product is in conformity with performance standards for sunlamp products under CFR21 Part 1040 04438 0 Note Description of skin types see Page 15...

Страница 4: ...to your long term satisfaction with your device Following the tips and instructions in the instruction manual will ensure you enjoyment and pleasure with your device In case of any questions we are al...

Страница 5: ...nce Fold out page 27 Maintenance overview 27 Maintenance intervals installed lamps and order numbers 28 Cleaning replacing UV low pressure lamps in sunbed base 33 Cleaning replacing UV low pressure la...

Страница 6: ...on for a better understanding of the processes Type and source of danger e g DANGER High voltage DANGER Description of the consequences e g You can be killed or injured by an electric shock Countermea...

Страница 7: ...ning All danger and safety labels attached to the device must be observed Do not remove them No safety equipment e g panel switch may be removed or deacti vated which can impair the safe operation of...

Страница 8: ...ification is not possible However the radiation time may not be extended as desired within the scope of the permissible radiation doses Therefore only a certain degree of final tanning dependent on th...

Страница 9: ...Inform Customer Service Soltron key Do not touch hot surface UV low pressure lamp s Starter for low pressure lamp s UV high pressure lamp s Filter panels General Symbols Cleaning and disinfectant agen...

Страница 10: ...n safety switch Unscrew release screw with Soltron key Tighten lock screw with Soltron key Two persons are required for this work step Suction cup Cleaning Replacing Clean or replace depending on soil...

Страница 11: ...there The manufacturer shall assume no liability whatso ever in case of non observance We explicitly emphasize that high liabil ity risks may occur for the exporter an or the operator in case of non o...

Страница 12: ...UTION Cosmetics or sun screen products must be removed prior to tanning as they can cause damage e g fine cracks on the surface when used continuously Maintenance and care Maintenance and care play a...

Страница 13: ...cause damage due to chemical reactions may also not be used Plastic surfaces For cleaning the other plastic surfaces it is best to use warm water and a leather cloth Never use aggressive cleaningagen...

Страница 14: ...pleasantly and with fewer worries as the radiation dosage can be exactly defined with sunbeds Certain drugs particularly those that produce photosensitivity may cause individuals under the influence...

Страница 15: ...he skin should be thoroughly cleaned and dried before each sunbath Many facial makeups have oil bases and should be removed prior to a session Adequate ventilation of the room or booth housing the tan...

Страница 16: ...16 General tanning instructions Please read and observe...

Страница 17: ...elf During the preparation time you can switch on the UV lamps at any time by pressing the START STOP button Remove your clothes and all jewelry Remove make up and other cosmetics Remove glasses Conta...

Страница 18: ...ted during tanning by switching off the UV lamps Press START STOP for three 3 seconds to pause or stop tanning Press START STOP again for three 3 seconds to restart the lamps Settings during start up...

Страница 19: ...ace tanner OFF Press button for three 3 seconds Switching on face tanner again Press button again It takes approx one 1 minute until the face tanners reach their full output Press for three 3 seconds...

Страница 20: ...d cooling Adjust speed 04202 0 Press button to change the intensity of the air stream Switching the body ventilator OFF Press button for three 3 seconds Switching on again Press button again 04252 0 1...

Страница 21: ...23 Operation 3s 04402 0 4 04202 0 5...

Страница 22: ...uper Rated power consumption 9 800W Rated voltage 230 V Rated frequency 60 Hz Rated fusing 40 amp 3 pole 60 amp 2 pole Conformity mark Powerinput 3 pole max 50 amp 230V AC 60 Hz Powerinput 1 pole max...

Страница 23: ...in F 28 35 in Maximum room temperature Humidity 03173 1 Warning possible breakage of the acrylic panel WARNING Severe cuts from glass and burns from hot lamps may result Only one adult person is allow...

Страница 24: ...26 Technical data...

Страница 25: ...29 Maintenance 50 h 3 4 x 51937 40 5 2 x 800767 41 Scheduled maintenance filters...

Страница 26: ...be operated with different wattages UV low pressure lamps Clean with plain water damp cloth S 40 Champ Super 500 h a 3 x JK 100723 400 W 100723 37 b 14 x Soltron VHP 15 120 W 12555 33 c 24 x Soltron...

Страница 27: ...31 Maintenance Filter panels Clean with plain water damp cloth 1 500 h 5 702808 33 3 000 h 1 702609 37 Scheduled maintenance Filter panel...

Страница 28: ...00 a m 17 00 p m CST CAUTION Damage due to improper maintenance Improper maintenance can cause the device to be damaged or to become unusable Always comply with the specified maintenance intervals Fol...

Страница 29: ...33 Maintenance 04209 0 De energize device 04210 0 1 2 2 1 04211 0 2 04212 0 3 2 1 03108 0 4 UV low pressure lamps lower section...

Страница 30: ...34 Maintenance 03099 0 5 Close 2 1 3 04213 0 6...

Страница 31: ...py panel is heavy and falls down by itself after uns crewing the 3 screws Support canopy panel Loosen screws in the specified order De energize device 1 3 2 1 2 3 04215 0 1 Caution Protect acrylic gla...

Страница 32: ...36 Maintenance 03099 0 5 04224 0 6 Close 2 1 3 1 2 3 04217 0 7...

Страница 33: ...nopy panel is heavy and falls down by itself after uns crewing the 3 screws Support canopy panel Loosen screws in the specified order De energize device 1 3 2 1 2 3 04215 0 1 Caution Protect acrylic g...

Страница 34: ...7 0 5 03896 0 6 03897 0 7 02757 0 8 CAUTION Do not touch the glass bulbs of the UV high pressure lamps with your bare fingers Remove soiling thor oughly Only touch new UV high pressure lamp with a clo...

Страница 35: ...39 Maintenance Check safety switch 2 1 03899 0 10 03699 0 11 1 3 2 04288 0 12 03901 0 13 04224 0 14 Close 2 1 3 1 2 3 04217 0 15...

Страница 36: ...40 Maintenance 04197 0 De energize device 2 1 04222 0 1 2 1 4x 04225 1 3 Hand wipe lightly dry or with water or use a vacuum cleaner 03319 0 2 04226 0 4 04227 0 5 Lower section filter...

Страница 37: ...41 Maintenance 04228 0 Caution Protect canopy with blanket 2 2 1 04430 0 1 04229 0 2 Rinse with water or replace 04047 0 3 04230 0 4 Canopy filter mats...

Страница 38: ...y switch has responded Has the bed been closed Has the lower acrylic glass panel bed been closed Has the upper panel been closed Have the filter panels been closed 40 33 35 37 Electronic problem Press...

Страница 39: ...39 Filter lower section cleaning 40 Frequency 24 Fusing 24 G Global Service Division II I Intended use 7 L Label II Load maximum 25 Long term consequences 8 M Maintenance schedules 29 Minors 8 O Oper...

Страница 40: ...0 Safety switch 10 Soltron key 9 Visual inspection 10 T Tanning instructions 14 Tanning times III Technical data 24 Termination of tanning 20 Troubleshooting 42 Type label II U UL Standard 11 UV high...

Страница 41: ...l customer completes and returns the en closed warranty card within 10 days after purchase to insure valid regis tration and coverage for potential claims If the warranty card is not registered proof...

Страница 42: ...no liability for the cost of removing defective sheets or installing replacement sheets nor for damage to persons or property To make a claim contact an authorized dealer or distributor of Soltron or...

Страница 43: ...dealer distributor of the serial number model number and date unit was purchased This will initiate the Warranty Claim process Upon determination of the problem your dealer distributor can then sup pl...

Страница 44: ...fere with the designed function of the unit This warranty does not include failure of the product due to alteration modifications misuse abuse improper maintenance improper installa tion or repair Thi...

Страница 45: ......

Страница 46: ...Soltron Inc Business centre 2950 Xenium Lane North Suite 150 Plymouth MN 55447 Indiana Phone 1 866 243 9861 www soltron us 801233 Index b us 01 2004...