background image

INSTALLATION INSTRUCTION MANUAL

LED CANOPY LIGHT,

Rev A JUN 2017

SERIES: TLCLF150XYYZZ; TLCLF150HXYYZZ

1. Introduction

„

An internal power-factor-corrected switch-mode supply allows it to be used from

any nominal 100V-277V,277-480V 60Hz AC supply without any variation in light output.

„

Suitable for use in the following locations:

• Ambient Temp: -20~+40°C
• Wet Locations

Note

: Save these instructions for future reference.

2. Installation

For supply connections use wire rated for at least 100°C

.

Installation Steps:

1. Mount throughout the roof

1. Use the existing hole on the roof or open a 4” hole. Seee fig. 1.

2. Put silicon sealant around the hole, let the thread on fixture through out the roof, and use the plate, gasket

and 4 screws to secure the fixture. See fig. 2.

3. One side of the pipe thread on the fixture, the other side insert to the driver box and secured by flange nut.

See fig. 3.

4. Connect the wiring to line wires, black-black, white-white and green-green.
5. Close the cover of the driver box.

Item

Model

Input Voltage

Power Factor

Watt

Input Current

Weight

A

TLCLF150XYYZZ

120-277VAC

ш0.9

150W

1.8A Max.

7.0 KG

B

TLCLF150HXYYZZ

277-480VAC

150W

0.88A Max.

7.0 KG

Warning:

To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and
maintained by a qualified electrician only, in accordance with all applicable electrical codes.

Warning:

To avoid electric shock:
•Be certain electrical power is OFF before and during installation and maintenance.
•Luminaire must be connected to a wiring system with an equipment-grounding conductor.

Warning:

To avoid explosion:
•Make sure the supply voltage is the same as the rated luminaire voltage.
•Do not install where the marked operating temperatures exceed the ignition temperature of the hazardous
atmosphere.
•Do not operate in ambient temperatures above those indicated on the luminaire nameplate.

Rev   B    JAN    2019

15.4 LBS

15.4 LBS

STL-CLF150XYYZZ
STL-CLF150HXYYZZ

STL-CLF150XYYZZ; STL-CLF150HXYYZZ

FOR MORE LIGHTING INFO CALL

1460 PARK AVENUE, EMERYVILLE, CA 94608

510.891.1056

[email protected] 

SOLTECHLIGHTING.COM

Отзывы: