Technical
Service
as
at:
08/07/2009
phone: +49 30 81879 0 fax: +49 30 81879 9999
www.solon.com
33
Annex 4 Sheet 5.1
SOLON P220/6+ (Horizontal Assembly / Pitched Roof or Slanted Roof)
Allowable
snow
loads
on
the
ground
s
kallow
in
kN/m²
according
to
DIN
1055-5
(Version
07.2005)
depending
on
the
pitch
of
the
roof
and
the
module
and
the
speed
pressure
q
in
kN/m²
Only
optimum
support
and
attachment
area
allowed
Speed pressure q = 0.65 kN/m²
β
0°
1°
2°
3°
4°
5°
6°
7°
8°
9°
10°
1.38
1.39
1.40
1.42
1.43
1.44
1.45
1.46
1.47
1.48
20°
1.49
1.51
1.52
1.54
1.56
1.57
1.59
1.62
1.64
1.66
30°
1.69
1.78
1.87
1.98
2.10
2.22
2.37
2.53
2.70
2.90
40°
3.12
3.37
3.66
3.99
4.36
4.80
5.33
5.94
6.69
7.59
50°
8.67
10.06
11.83
14.10
17.26
21.80
28.50
40.17
64.02 132.99
60°
No calculative consideration of the snow load, usable in all snow load zones.
Speed pressure q = 0.75 kN/m²
β
0°
1°
2°
3°
4°
5°
6°
7°
8°
9°
10°
1.37
1.38
1.39
1.40
1.41
1.43
1.43
1.44
1.45
1.46
20°
1.47
1.48
1.50
1.51
1.53
1.54
1.56
1.58
1.60
1.63
30°
1.65
1.73
1.83
1.93
2.04
2.16
2.30
2.45
2.62
2.81
40°
3.02
3.26
3.53
3.85
4.20
4.62
5.13
5.71
6.43
7.29
50°
8.33
9.65
11.35
13.52
16.55
20.89
27.29
38.45
61.25 127.18
60°
No calculative consideration of the snow load, usable in all snow load zones.
Speed pressure q = 0.85 kN/m²
β
0°
1°
2°
3°
4°
5°
6°
7°
8°
9°
10°
1.35
1.36
1.37
1.38
1.40
1.41
1.42
1.42
1.43
1.44
20°
1.45
1.46
1.47
1.48
1.50
1.51
1.53
1.55
1.57
1.59
30°
1.61
1.69
1.78
1.88
1.98
2.10
2.23
2.38
2.53
2.72
40°
2.92
3.14
3.41
3.71
4.04
4.44
4.92
5.48
6.17
6.99
50°
7.98
9.25
10.87
12.94
15.83
19.97
26.08
36.73
58.48 121.37
60°
No calculative consideration of the snow load, usable in all snow load zones.
Speed pressure q = 0.95 kN/m²
β
0°
1°
2°
3°
4°
5°
6°
7°
8°
9°
10°
1.34
1.35
1.36
1.37
1.38
1.39
1.40
1.40
1.41
1.42
20°
1.43
1.43
1.44
1.46
1.47
1.48
1.50
1.51
1.53
1.55
30°
1.57
1.65
1.73
1.82
1.93
2.04
2.16
2.30
2.45
2.62
40°
2.82
3.03
3.28
3.56
3.88
4.26
4.72
5.25
5.91
6.69
50°
7.64
8.85
10.39
12.36
15.12
19.06
24.88
35.01
55.71 115.56
60°
No calculative consideration of the snow load, usable in all snow load zones.
Speed pressure q = 1.00 kN/m²
β
0°
1°
2°
3°
4°
5°
6°
7°
8°
9°
10°
1.33
1.34
1.35
1.36
1.37
1.39
1.39
1.39
1.40
1.41
20°
1.41
1.42
1.43
1.44
1.45
1.47
1.48
1.50
1.51
1.53
30°
1.55
1.63
1.71
1.80
1.90
2.00
2.13
2.26
2.41
2.58
40°
2.77
2.97
3.22
3.49
3.80
4.17
4.62
5.14
5.78
6.55
50°
7.47
8.64
10.15
12.07
14.76
18.60
24.27
34.15
54.33 112.66
60°
No calculative consideration of the snow load, usable in all snow load zones.
SOLON M230/6+ is structurally identical with SOLON P220/6+.
Annex 4 Sheet 5.2