ABSTRACT OF THE ASSEMBLY INSTRUCTIONS FOR SOLON STANDARD MODULES
Approval
of
the
assembly
methods
shown
here
is
only
given
up
to
the
specified
resulting
load
carrying
capacity
of
the
surface
in
kN
per
m²
of
module
surface
,
which
can
be
found
in
the
assembly
instructions
for
the
respective
module
(Table
1).
This
is
the
basis
for
the
calculation
of
the
allowable
snow
load
on
the
ground
s
kallow
(Annexes
3
through
6
of
the
Assembly
instructions).
All
results
conform
to
the
currently
valid
standards
and
regulations
(e.g.
wind
load
according
to
DIN
1055-
Part
4
(03/2005)
and
snow
load
according
to
DIN
1055-Part
5
(07/2005)).
1. Vertical Assembly
2. Horizontal Assembly
Horizontal girder profiles Vertical girder profiles
The
frame
of
the
module
must
be
connected
without
deformation
at
four
points
in
the
areas
"
M
s
"
and
"
M
w
",
respectively,
to
the
rails
of
the
substructure
(girder
profiles).
An
attachment
to
the
short
spars
is
not
allowed
on
principle.
M
w
M
w
a
op
tim
al
a
mi
n
M
s
M
s
Required area for attachment and support
a
optimal