background image

 

 

 

 

 

 

 

 

 

 

Sollae Systems Co., Ltd. 

http://www.ezTCP.com 

 

 

Serial  ↔  LAN/WLAN Converter 

CSC-H64 User Manual

 

Version 1.0 

Содержание CSC-H64

Страница 1: ...Sollae Systems Co Ltd http www ezTCP com Serial LAN WLAN Converter CSC H64 User Manual Version 1 0...

Страница 2: ...nsuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of thi...

Страница 3: ...7 3 USB Setup Port for connection with a PC 14 1 7 4 Function Button Func 14 1 7 5 Supplying Power 15 1 7 6 USB Host Port for Connection with WLAN adapter 15 1 7 7 Serial interface 16 1 7 8 Ethernet...

Страница 4: ...mode 37 4 4 Normal Mode 37 4 5 Button Setup Mode 38 4 6 ISP Mode 38 5 Communication Mode 39 5 1 TCP Server 39 5 1 1 Key parameters 39 5 1 2 Examples 40 5 2 TCP Client 43 5 2 1 Key parameters 43 5 2 2...

Страница 5: ...8 2 Serial Port Tab Functions 72 8 2 1 TCP Server Client mode 72 8 2 2 Separator 73 8 2 3 TELNET COM port Control Option RFC 2217 73 8 2 4 Disable TCP Transmission Delay 73 8 2 5 SSL 73 8 1 Additional...

Страница 6: ...CSC H64 User Manual Ver 1 0 5 http www ezTCP com 12 1Precaution 79 12 2Exemption from Liability 80 12 2 1 English version 80 12 2 2 French version 81 13 Revision History 83...

Страница 7: ...erature range of 40 85 without a USB WLAN adapter along with an overvoltage reverse voltage and overcurrent protection circuit makes this Serial to Ethernet WLAN converter suitable for harsh industria...

Страница 8: ...H64 User Manual Ver 1 0 7 http www ezTCP com 1 3 Application Examples 1 3 1 Wired LAN 1 1 Connection with a PC Figure 1 1 1 1 connection with a PC Multiple serial ports Figure 1 2 multiple serial por...

Страница 9: ...CSC H64 User Manual Ver 1 0 8 http www ezTCP com Applied to LAN Figure 1 3 applied to LAN Applied to the Internet with an IP Share Router Figure 1 4 applied to the Internet with an IP share router...

Страница 10: ...com Applied to a serial tunneling system Figure 1 5 applied to a serial tunneling system 1 3 2 Wireless LAN 1 1 network with a PC Figure 1 6 1 1 network with a PC 1 1 network with a PC through an AP F...

Страница 11: ...onnection with a xDSL cable modem Figure 1 8 Internet connection with an xDSL cable modem 1 4 Components CSC H64 s body DVD including utilities and documents optional USB WLAN adapter optional DC 5V p...

Страница 12: ...WLAN adapter Approval KC CE FCC RoHS RoHS Compliant Table 1 1 hardware specification 1 5 2 Software Protocol TCP UDP IPv4 IPv6 dual stack ICMPv6 TCPv6 UDPv6 ICMP ARP DHCP PPPoE DNS DDNS Dynamic DNS T...

Страница 13: ...CSC H64 User Manual Ver 1 0 12 http www ezTCP com 1 6 Dimensions 1 6 1 Dimensions Figure 1 9 dimensions Dimensions may vary according to a method of measurement...

Страница 14: ...Interface 1 7 1 Panel Layout Figure 1 10 panel layout LED PWR STS TX RX Ethernet port 10 100M USB Host port USB Wireless LAN adaptor connection USB Setup port For connecting to ezManager Power port D...

Страница 15: ...mode Button Setup mode STS Yellow Blinks simultaneously Entering Button Setup mode TX1 4 Green RX1 4 Green Table 1 3 LED status on the top panel Please refer to the Table 9 1 LED status according to s...

Страница 16: ...ort Setup Port You can supply DC 5V power through this port Note that unstable operation may be occurred in case of supplying power via this port due to insufficient current 1 7 6 USB Host Port for Co...

Страница 17: ...RS232 Number Name Description level type Etc 1 DCD Data Carrier Detect RS232 IN N C 2 RXD Receive Data RS232 IN required 3 TXD Transmit Data RS232 OUT required 4 DTR Data Terminal Ready always output...

Страница 18: ...ssignment in RS422 Pin Assignment in RS485 Number Name Description level type Etc 9 TRX Data RS485 IN OUT required 1 TRX Data RS485 IN OUT required 5 GND Ground required Table 1 6 pin assignment in RS...

Страница 19: ...1 13 Ethernet connector interface RJ45 Ethernet port interface RJ45 Number Name Direction 1 TX Output 2 TX Output 3 RX Input 4 5 6 RX Input 7 8 Table 1 8 RJ45 the Ethernet port interface LED indicato...

Страница 20: ...igure 2 1 Ethernet connection 2 1 2 Wireless LAN Mode If the USB WLAN adapter is connected CSC H64 operates in WLAN mode CSC H64 supports IEEE802 11b g IEEE802 11 standard that is called Wi Fi has thr...

Страница 21: ...nfrastructure In this mode every wireless LAN station communicates through an Access Point AP which is able to interface with both Wireless LAN and Ethernet so that all stations can be connected to Et...

Страница 22: ...an easy way to set up network since wireless LAN stations communicate each other without an AP in this mode It is suitable for a small scale network if wired LAN is not available Usually it is called...

Страница 23: ...ent allow you to communicate with not only laptops and smartphones but also devices without Ad hoc function CSC H64 supports Soft AP function While operating in this function it has 10 1 0 1 as its IP...

Страница 24: ...N station should get authentication from the AP in the infrastructure network There are two methods for the authentication Open System and Shared Key WEP Wired Equivalent Privacy The WEP is a security...

Страница 25: ...e 2 8 connection between CSC H64 and a PC Wireless LAN Make sure that a connection between your PC and CSC H64 is established via Serial and wireless LAN This section is an example which is based on I...

Страница 26: ...C can be established Setting of the PC Add or change the IP address of the network adapter on your PC like the following Get into the menu of Windows Control Panel Network Connections Properties of th...

Страница 27: ...t to your system proper values should be set via ezManager Major parameters default values are listed on below table To implement this simple test keep these values without any changes Name Default Va...

Страница 28: ...a LAN Figure 2 11 settings for TCP connection Select TCP Client Input a correct IP address and a port number of CSC H64 Clink the Connect button In case of TCP Server it will be Listen button Opening...

Страница 29: ...zTCP com Confirm the TCP Connection and COM port status Figure 2 13 TCP Connected message Press Check the message if the TCP connection has been established Figure 2 14 COM Port open message Check the...

Страница 30: ...ission test Figure 2 15 successful data transmission Click the Send data on the LAN part Check the data has been shown from the step Figure 2 16 LAN RS232 Press the Send data on the RS232 part Check t...

Страница 31: ...ly RX TX and STS LEDs will be blink Connecting to Wireless LAN using Soft AP Connect your laptop or smartphone to Wireless LAN Wi Fi network using CSC H64 s Soft AP function The SSID is cfg_MAC Addres...

Страница 32: ...tp www ezTCP com Figure 3 2 Connecting to Web configuration page PC Mobile Set additional environmental variables through ezManager After connecting to WLAN you can set additional environmental variab...

Страница 33: ...2 http www ezTCP com 3 1 2 Setting by wired LAN ezManager and LAN adaptor are required on your PC Supplying power LAN Connection Connect CSC H64 to your PC via a LAN cable Run ezManager and set parame...

Страница 34: ...utomatic installation fails download and install the driver on ST Micro s web site STM32 USB Virtual Com Port Driver Download page http www st com web catalog tools FM147 CL1794 SC961 SS1533 PF257938...

Страница 35: ...CSC H64 User Manual Ver 1 0 34 http www ezTCP com Writing the environment parameters Figure 3 5 ezManager USB...

Страница 36: ...nd Procedures Supply the power Connect the serial cable Set the communication mode to the AT command Run a serial terminal program like Hyper Terminal Set the values properly with the AT commands Save...

Страница 37: ...different connection modes Configuring parameters is also available in this mode Button Setup mode This mode is for configuring environmental parameters through the USB port ISP mode You can set envi...

Страница 38: ...requests from TCP clients Passive Connection TCP Client Send connection requests to a TCP server Active Connection AT Command Control connections by AC commands Active Passive Connection UDP Communic...

Страница 39: ...can enter this mode by pressing the function button over 1 second CSC H64 offers restriction methods for security like filtering passwords or MAC and IP addresses In the ISP mode you can revoke all o...

Страница 40: ...TCP connection is established Value Description 0 CSC H64 does not send the data Otherwise 512 or under CSC H64 sends the data right after a connection is established 512 or under bytes are strongly...

Страница 41: ...on requests Remote host sends a connection request SYN segment Processes of the connection The connection is established Data communication is implemented on both side Table 5 2 states of each point L...

Страница 42: ...e host sends a connection request SYN segment Processes of the connection The connection is established Data communication is implemented on both sides Table 5 3 states of each point As you can see th...

Страница 43: ...t Points States Data communication on both sides The last segment arrives at CSC H64 No data communication for 5 seconds CSC H64 sends a disconnection request FIN to a remote host Processes of the dis...

Страница 44: ...up Otherwise 512 or under Right after the bytes set to Event Byte have been received from the serial port Setting to less than 512 bytes is strongly recommended Table 5 5 the operation of Event Byte...

Страница 45: ...et CSC H64 sends a connection request segment right after it boots up processes of TCP connection The connection is established data communication on both sides Table 5 7 states of each point Look at...

Страница 46: ...after receiving 5 bytes processes of the TCP connection The connection is established The data 1234567 is transmitted to the remote host Table 5 8 states of each point As you can see CSC H64 has sent...

Страница 47: ...lished CSC H64 is online and processes of the disconnection The connection is terminated Both sides are offline Sends TCP connection request segment Table 5 9 states of each point The TCP Server Clien...

Страница 48: ...CR PTO Timeout at pto 10 CR WCCT WLAN Topology at wcct 1 CR WSSID SSID at wssid sollae CR PWP Store setting at pwp CR Table 5 10 some of extended AT commands for configuration Related items with an IP...

Страница 49: ...arameters with AT commands ATA command has arrived CSC H64 listens to TCP connection requests A remote host sends SYN segment to CSC H64 processes of TCP connection TCP connection is established CSC H...

Страница 50: ...tive connection Figure 5 8 time chart Time States configuring parameters with AT commands CSC H64 sends TCP connection request with the ATD command processes of TCP connection TCP connection is establ...

Страница 51: ...nnection is off line CSC H64 sends FIN segment right after the ATH arrives processes of TCP disconnection TCP connection is terminated CSC H64 sends NO CARRIER with disconnection Table 5 13 states of...

Страница 52: ...Block Size is to set the time to gather data in one block Its unit is byte If the data in configured size of the Block Size comes into the serial port CSC H64 will send them as one block to the netwo...

Страница 53: ...o CSC H64 Data 678 arrives CSC H64 sends data from the remote host to the serial device 2bytes time passes CSC H64 sends data 678 as one block based on the Data Frame Table 5 14 states of each point C...

Страница 54: ...Address 0 None Peer Port 0 Table 5 15 setting for dynamic update of a peer host function Figure 5 11 time chart Time States Sending any UDP data to the network is impossible UDP data arrives from Rem...

Страница 55: ...the latest version of the firmware 6 1 2 Processes Downloading the latest firmware Download the latest firmware file uploaded at our website Run ezManager program for sending the Firmware file Run the...

Страница 56: ...nual Ver 1 0 55 http www ezTCP com Checking firmware file and Sending Figure 6 2 sending firmware file Check if the name and path of the firmware file are correct Click the Send button Confirm the com...

Страница 57: ...4 on TELNET The following commands let users check each state Command Option Description Usage st net IPv4 Network Status lsh st net net6 IPv6 Network Status lsh st net6 sio Serial Port Status lsh st...

Страница 58: ...lays the current IPv6 network states of all sessions Figure 6 5 st net6 command st sio st sio command displays the number of bytes for the serial port Figure 6 6 st sio command st uptime st uptime com...

Страница 59: ...P2 should be close Figure 6 8 sc command In case of the sc command you should use only small letters sd sd command is for capturing serial data OP1 means name of the session OP2 means period which has...

Страница 60: ...w the status is automatically updated in every second Figure 6 11 status window of ezManager FIRMWARE VERSION The name of model name and the version of firmware are displayed here SYSTEM UPTIME Amount...

Страница 61: ..._SENT Send SYN segment to make TCP connection ESTABLISHED When TCP connection is established N A In UDP mode Table 6 2 TCP state SSL STATUS SSL certificate status of CSC H64 is displayed SERIAL STATUS...

Страница 62: ...the opponent after it sends Neighbor Solicitation and receives Neighbor Advertisement STALE The device will change into STALE state later after some time later reaching REACHABLE DELAY The device wil...

Страница 63: ...ption is checked ezManager send query in every second IP address Conflict Detection By clicking this button you can find devices which have the same IP address to yours on the network Figure 6 12 in c...

Страница 64: ...et The SSL works over TCP 7 1 2 How to set the SSL To works for SSL you have to set the SSL related parameters as the following steps Set the SSL check box in the ezManager Figure 7 1 setting of optio...

Страница 65: ...the key length and information in Self signed certificate Figure 7 4 input the information Check a success message Figure 7 5 check of success message 7 1 3 Restriction If user set the SSL with the C...

Страница 66: ...255 0 10 1 0 1 10 1 0 254 192 168 1 4 255 255 255 255 192 168 1 4 Table 7 1 examples of defining allowed IPv4 range Apply to ezManager Apply to ezManager is for applying above two restrictions to ezM...

Страница 67: ...key settings Type Digit Example WEP64 64bits ASCII 5 abcde Hexadecimal 10 6162636465 WEP128 128bits ASCII 13 0123456789abc Hexadecimal 26 30313233343536373839616263 Table 7 3 WEP key settings 7 2 4 Us...

Страница 68: ...roduct Select one of authentication protocols on 802 1X item in the Security Settings Protocol required configurations EAP TLS ID of radius server account client certificate EAP TTLS ID and passphrase...

Страница 69: ...User Manual Ver 1 0 68 http www ezTCP com Save the client certificate made by radius server Figure 7 8 saving client certification Input password for the certificate Check the information of the cert...

Страница 70: ...802 11b and 802 11b g mode Short Preamble Under good condition of WLAN environment you can expect a slight improvement by enabling this option Otherwise you had batter to disable this option Short Sl...

Страница 71: ...create host names on the website of DynDNS before you use All about service usage of an account could be changed according to the policy of DynDNS DynDNS website http dyn com dns Figure 8 1 setting D...

Страница 72: ...address to the remote host right after the connection is established By using this function a server can identify multiple devices with the information Figure 8 2 setting of Sending MAC Address functi...

Страница 73: ...s 8 2 1 TCP Server Client mode This mode is available on TCP client mode only In this mode you do not need to change the mode for switching between active and passive TCP connection Note that the Even...

Страница 74: ...port states between two devices You can send and receive control signals such as RTS CTS when the states are changed Refer to the TELNET COM Port Control Option document on our website for details 8...

Страница 75: ...Factory Reset Enter the Button setup mode LEDs blinks Press the function button over 10 seconds LEDs will be ON sequentially Factory Reset will be automatically implemented to default values Reboot Se...

Страница 76: ...r TCP IP Connection with the network Check if CSC H64 is successfully connected in network Symptoms LED status Not connecting a LAN cable or a USB WLAN adapter RX1 and TX1 LED blink alternately Not co...

Страница 77: ...heck the network environment Network Firewall In the case of networks with strong security the access may be denied by their firewall Under this circumstance consult the network administrator to relea...

Страница 78: ...ded DVD in your package Datasheet CE certificate Declaration of RoHS Compliance IP Change Notification DDNS Sending MAC Address function TCP Server Client mode Telnet COM Port Control Option Separator...

Страница 79: ...customer s request to refund the product within two weeks after purchase Sollae Systems will refund the product 11 2 2 Free Repair Services For product failures occurring within 2 years after purchase...

Страница 80: ...applications provided by Sollae Systems for purposes other than those for which they were designed is prohibited Do not use the product in an extremely cold or hot place or in a place where vibration...

Страница 81: ...cars planes trucks boats aircraft helicopters etc In the same way the CSC H64 is not designed or intended or authorized to test develop or be built into applications where failure could create a dange...

Страница 82: ...et de donn es caract re commercial ou de toute autre perte financi re provenant de l utilisation ou de l incapacit pouvoir utiliser le bo tier CSC H64 m me si Sollae Systems Co Ltd ou un de ses distri...

Страница 83: ...fecter la fiabilit cr er des dysfonctionnements et ou la destruction du bo tier CSC H64 sans que la responsabilit de Sollae Systems Co Ltd et de ses distributeurs ne puissent tre mise en cause ni que...

Страница 84: ...CSC H64 User Manual Ver 1 0 83 http www ezTCP com 13 Revision History Date Version Description Author 2015 05 21 1 0 Initial release Amy Kim...