10. Specifications
10. Specifications
.58.
.59.
Dimensions (W*H*D)
Weight
84kg
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated grid output current (Amps)
Power Factor (at rated output power)
Max.efficiency
EU efficiency
Model
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
1100
10/20
50/60
98.7%
98.3%
Transformerless
-25
℃...
+60
℃
0~100%
IP66
4000m
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
600
110000
121000
121000
167.1/158.8
183.8
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
180...1000
195
S5-GC110K
Max. output current (Amps)
AC connection
Grid connection standard
DC connection
Display
Communication connections
Warranty
MC4 connector
OT Terminal (max 185 mm²)
LCD, 2×20 Z
RS485, Optional: Wifi, GPRS , PLC
5 years (extand to 20 years)
VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1,
UTE C15-712-1, NRS 097-1-2, G98, G99,
EN 50549-1/-2, RD 1699, UNE 206006,
UNE 206007-1, IEC61727,DEWA
Safty/EMC standard
3/N/PE, 220/380, 230/400
1065*567*344.5mm
>
0.99 (0.8 leading - 0.8 lagging)
Operating frequency range (Hertz)
45...55 or 55...65
<
2W
Noise emission (typical)
≤
65 dBA
Intelligent redundant cooling
Dimensions (W*H*D)
Weight
84kg
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated grid output current (Amps)
Power Factor (at rated output power)
Max.efficiency
EU efficiency
Model
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
1100
10/20
50/60
99.0%
98.5%
Transformerless
-25
℃...
+60
℃
0~100%
IP66
4000m
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
720
125000
137500*
137500*
150.4
165.4
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
180...1000
195
S5-GC125K-HV
Max. output current (Amps)
AC connection
Grid connection standard
DC connection
Display
Communication connections
Warranty
MC4 connector
OT Terminal (max 185 mm²)
LCD, 2×20 Z
RS485, Optional: Wifi, GPRS , PLC
5 years (extand to 20 years)
VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1,
UTE C15-712-1, NRS 097-1-2, G98, G99,
EN 50549-1/-2, RD 1699, UNE 206006,
UNE 206007-1, IEC61727,DEWA
Safty/EMC standard
3/PE, 480
*135000 for VDE-AR-N 4105
1065*567*344.5mm
>
0.99 (0.8 leading - 0.8 lagging)
Operating frequency range (Hertz)
45...55 or 55...65
<
2W
Noise emission (typical)
≤
65 dBA
Intelligent redundant cooling
10*32
10*50
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
10*32
10*50
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4