11
User Manual
MHT-4~20K series
3.2.3 Indicator
Figure 3-4 Inverter display interface
Item
Indicator
Status
Description
1
Power and
Alarm Indicator
Off
No power
.
Blue
Quick flashing
Inverter entered self-test status.
Slow flashing
Inverter entered waiting status.
Breathe flashing
Inverter works normal.
Orange
Breathe flashing
Low battery warning, the battery power is
about to reach the SOC protection value.
Red
Always on
An alarm or fault is detected, view the fault
info on the display.
2
Grid
Indicator
Off
Grid lost.
Slow flashing
Inverter detected grid but not running in on-grid mode.
Always on
Inverter works in on-grid mode.
3
Communica-
tion Indicator
Green
Always on
The inverter communication is running nor
-
mally.
Green
Flashing
The inverter communicates with EMS or
Master inverter through RS485 or CAN.
Orange
Always on
The inverter has not established communi
-
cation with Solinteg smart meter.
Red
Always on
The inverter has not established communi
-
cation with the BMS.
4
Display
Display off to save power, press the button to wake up the display.
5
Button
Switch display information and set parameters by short press or long press.
1
3
2
4
5