2.  Drill  holes  in  points  where  you  wish  to  install  the 

alarm. Use rear cover as template. 

3.  Use  screws  and  dowels  attached  to  the  product 

package;  do  not  apply  excessive  force  while 
tightening  the  screws.  Use  more  suitable fastening 
material when necessary. 

4.  Insert two AAA alkaline batteries. Mind the indicated 

polarity. 

5.  Attach  the  detector  to  the  rear  cover  and  rotate  it 

clockwise to fix it. 

 
Functional test 

The detector is equipped with a diagnostic circuit, testing the sensor’s and siren’s function every ten 
seconds. However, we recommend you to test the device for function every month. You can  do it 
as follows. 

Push the TEST/HUSH button shortly. Afterwards, you will hear the alarm signal and the LED diode 
(alarm) will flash 4 times in four series in a row. This indicates correct function. 

Alarm mode

 

If harmful CO concentration is detected, the detector will switch to constant alarm mode. In such 
case, immediately proceed as follows: 

1.  Provide  ventilation  in  the  room  affected  and  leave  the  room.  If  no  ventilation  is  possible, 

immediately leave to fresh air or to another ventilated room with lower or no CO concentration 
at all. 

2.  If  there  is  anybody  inside  the  affected  room  experiencing  carbon  monoxide  poisoning 

symptoms described above, immediately call the ambulance and the fire brigade. All persons 
and animals must be immediately evacuated. Count all the present persons and animals to 
make sure nobody is forgotten. 

3.  Do  not  re-enter  the  affected  rooms  until  the  problem  has  been  resolved  and  until  carbon 

monoxide has diffused. Its concentration must sink to a safe level. The alarm will automatically 
stop signalling dangerous CO concentration when it drops to a safe level. 

Alarm activation values: 

CO level 

Reaction time 

Type of audible alarm 

30 

– 49PPM 

After 120 minutes 

2x sound signal at a frequency of 1s 

50 

– 99PPM 

After 60 

– 90 minutes 

3x sound signal at a frequency of 1s 

100 

– 299PPM 

After 10 

– 40 minutes 

4x sound signal at a frequency of 1s 

300PPM or more 

Up to three minutes 

4x sound signal at a frequency of 0.5s 

 
Silent alarm mode 

Solight 1D36 detector also has a silent alarm function If the detector triggers the alarm, it can be 
put on silent mode by pushing the TEST/HUST button. In this mode, the red (Alarm) diode will flash 
once  simultaneously  with  the  green  (Power)  diode  every  ten  seconds  for  two  minutes.  If  the 
concentration  of carbon monoxide  exceeds  300PPM  within three minutes,  the  loud  alarm  will  be 
trigged again. If the concentration drops below 5PPM (included), the alarm signal will stop. 

If you wish to exit the silent alarm mode, push the TEST/HUSH button repeatedly.

 

Backward warning function 

Rear cover (bracket) 

Tighten 

Release 