background image

 

Confidential & Proprietary                                      13/17 

 

3.1.3 

Optical Cabling 

N2ROU  makes  optical-electronic  conversion  of  TX  signals  from  upper  ODU  and  OEU  and 

makes  electronic-  optical  conversion  of  RX  signals.  N2ROU  has  one  optical  module  in  it.  As 

WDM is installed in the R_OPTIC module, two pieces of wavelength (TX:1310nm, RX:1550nm) 

can  be  sent/received  with  one  optical  core  at  the  same  time.  N2ROU  has  SC/APC  of  optical 

adaptor type. 

For  optical  adaptor,  SC/APC  type  can  be  used.  To  prevent the  optical  access  part  from  being 

marred  with  dirt,  it  should  be  covered  with  a  cap  during  move.  When  devices  are  connected 

through optical cables, you need to clear them using alcohocol to remove dirt. 

 

 

Optical cables should be inserted into Optic Port outside of N2ROU. 

Through GUI, check if PD value of ROPTIC is in a tolerable range (+5~1dBm). 

 

3.1.4 

GND Terminal Connection 

N2ROU has one GND terminal port where is on bottom side, like below   

Содержание Alliance_N2ROU

Страница 1: ...Confidential Proprietary 1 17 Alliance_N2ROU User Manual SOLiD Inc 10 9th Floor SOLiD Space220 Pangyoyeok ro Bundang gu Seongnam si Gyeonggi do Korea 393 400 Tel 82 31 627 6290 Fax 82 31 627 6209 ...

Страница 2: ...e technical support and or to establish a return authorization for defective units The serial numbers are located on the back of the unit as well as on the box in which they were delivered Additional support information may be obtained by accessing the SOLiD Tehcnology Inc website at www st co kr or send email at sjkim st co kr This manual is produced by Global Business Division Business Team 1 Pr...

Страница 3: ...liance_N2ROU 9 2 3 Dimension 10 Section3 System Installation 11 3 1 N2ROU Installation 11 3 1 1 N2ROU Enclosure installation 11 3 1 2 N2ROU Power Cabling 12 3 1 3 Optical Cabling 13 3 1 4 GND Terminal Connection 13 3 1 5 Coaxial cable and Antenna Connection 14 3 1 6 Insertion of N2RDU 14 3 1 7 N2RDU Specifications Per band 15 ...

Страница 4: ...Confidential Proprietary 4 17 Section1 Safety Certification Notice ...

Страница 5: ...ut any modifications or fit any spare parts which are not sold or recommended by the manufacturer This could cause fires electric shock or other injuries Any DAS system or Fiber BDA will generate radio RF signals and continuously emit RF energy Avoid prolonged exposure to the antennas SOLiD recommends maintaining a 3 foot minimum clearance from the antenna while the system is operating Do not oper...

Страница 6: ...ponents connected to this device must operate in the frequency range of this device Only 50 ohm rated antennas cables and passive components operating from 150 3 GHz shall be used with this device The head end unit must always be connected to the Base Station using a direct cabled connection This system has not been approved for use with a wireless connection via server antenna to the base station...

Страница 7: ...ed by the authority responsible for the location Notice Be careful not to touch the Heat sink part due to high temperature Use of unauthorized antennas cables and or coupling devices not conforming with ERP EIRP and or indoor only restrictions is prohibited Signal booster warning label message should include WARNING This is NOT a CONSUMER device It is designed for installation by an installer appr...

Страница 8: ...Confidential Proprietary 8 17 Section2 System Overview 2 1 Purpose 2 2 SMDR NH124 ...

Страница 9: ...uses both analog AMPS and digital TDMA CDMA and WCDMA methods The Alliance_N2ROU system supports communication standards and public interface protocols in worldwide use Frequencies VHF UHF 700MHz 800MHz 850MHz 1900MHz 2100MHz etc Voice protocols AMPS TDMA CDMA GSM IDEN etc Data protocols EDGE GPRS WCDMA CDMA2000 LTE etc 2 2 Alliance_N2ROU N2ROU receives TX optical signals from ODU or OEU and conve...

Страница 10: ...1 N2ROU Outer Look ROU is designed in a cabinet and provides the following functions and features Item Spec Remark Size mm 571 x 450 x260 Including Bracket Weight 39 Kg Full Load Power consumption 260 W Operating Temperature 10 to 50 C Ambient Temperature ...

Страница 11: ...ent of NEMA4 ROU can be mounted into either of on a Wall Basically N2ROU has both of a Wall Mount Bracket Depending on the use of the Rack Mount Bracket the bracket can be removed N2ROU component N2ROU has the following components No Unit Description Remark Common Part Enclosure Including Wall cradle 1EA RCPU 1EA R_OPTIC With SC ACP adaptor 1EA RPSU Alternative DC 48V or AC 120V 1EA Multi Plexer 5...

Страница 12: ... multiple TX RX signals through one antenna It should have Power Cable for external rectifier or to supply required power In addition N2RDU can be inserted and removed to provide service for desired band Optional 3 1 2 N2ROU Power Cabling N2ROU supports both of DC 48V and AC120V of input power As RPSU for DC 48 and RPSU for AC120V are separated from each other you need to select one of them in cas...

Страница 13: ...re at the same time N2ROU has SC APC of optical adaptor type For optical adaptor SC APC type can be used To prevent the optical access part from being marred with dirt it should be covered with a cap during move When devices are connected through optical cables you need to clear them using alcohocol to remove dirt Optical cables should be inserted into Optic Port outside of N2ROU Through GUI check...

Страница 14: ...check the VSWR value of coaxial cable whether it is within specification using SITEMASTER At this time check if the Return loss have above 15dB or VSWR have below 1 5 The part of antenna connection fasten to port not to be loosed and not to be injected the dusty and insects The antenna connected to N2ROU is only serviced in inbuilding 3 1 6 Insertion of N2RDU N2ROU has slots to enable up to four N...

Страница 15: ...quency range TX MHz RX MHz 700LTEF_FN 39 17 21 33 729 768 699 716 B1 777 798 B2 800IDEN 850Cell 32 32 33 862 894 817 849 1900PCS 65 65 33 1930 1995 1850 1915 AWS13 70 70 33 2110 2180 1710 1780 2300WCS 10 10 33 2350 2360 2305 2315 2 5TDD 71 2 LB UB 37 8 MB 32 2496 8 2568 LB 2574 1 2611 9 MB 2618 8 2690 UB 2 5TDD_MIMO ...

Страница 16: ...d such that a minimum separation distance of at least 200 cm is maintained between the radiator antenna and all persons at all times This device must not be co located or operating in conjunction with any other antenna or transmitter RSS GEN Sec 7 1 2 transmitters Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approve...

Страница 17: ...on Exposure This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 200 cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter RF exposure will be addressed at time of installation and the use...

Отзывы: