C100 HDS Installation Manual
Section 4 – Appendices
|
Page 4-3
Specifications
Blackrock processor
Parameter
Condition
Value
Unit
Notes
Height
2
U
89
mm
Width
19
in
Case only without rack ears
449
mm
Depth
429
mm
Excludes connectors/cables
Weight (†)
14
kg
Heat Dissipation
200
W
Shared between two PSUs
Voltage
Range
100 – 240
V
±10%, 50/60Hz AC only
Current
Maximum over voltage range
2.1 – 0.9
A
Maximum
Power Factor
0.95
Approximately
Fusing
Thermal current trip. No fuses
Noise
Front
50
NR
Both PSUs powered
Rear
55
NR
Both PSUs powered
Connectors
Power in 1 and 2
IEC male
Networks
RJ45
Sync In
BNC 75
Ω
Fibre I/O
Duplex LC
Multimode or singlemode to order
†
Blackrock processor units must be supported on rack shelves. Do not rely on the rack ears alone.
Rio
Parameter
Condition
Value
Unit
Notes
Height
7
U
665
mm
Width
19
in
Case only without rack ears
449
mm
Depth
344
mm
Excludes connectors/cables
Weight (†)
17 – 21
kg
Depending on I/O fitted
Heat Dissipation
5 Mic cards
500
W
Maximum
1 Mic, 2 analogue, 1 digital card
350
W
Typical
Voltage
Range
100 – 240
V
±10%, AC only
Current
Maximum over voltage range
5.6 – 2.3
A
Power Factor
0.95
Approximately
Fusing
Thermal current trip. No fuses
Noise
Front
45 – 55
NR
Variable speed fans
Rear
45 – 60
NR
Connectors
Power in 1 and 2
IEC male
Network
RJ45 100 baseT
(unused)
Sync out
BNC 75
Ω
(Wordclock)
Madi 1–4
Duplex LC fibre multimode
GPI Input
25-way D-type male
GPI Output
25-way D-type female
†
RIO units must be supported on rack shelves. Do not rely on the rack ears alone.