INS-TSSHC-3DNPSB-16.7A-1209
8
Adjustment procedure of the Automatic mode :
1. If necessary, adjust the Day/Night set point at
the desired temperatures. If needed, switch
from one mode to the other by simultane
ously pressing down the two buttons and
releasing them immediately.
2. From the Night mode, simultaneously press
down the two buttons for more than 3 sec
onds, until the icon SET starts to blink, in
dicating that the adjustment of the Night
mode timer is effective. The figures displayed
above the word “AMBIENT” indicate the cur
rent timer adjustment.
If needed, adjust the timer by pressing down
the right button to increase the value, or the
left button to decrease it. The Night mode
timer adjustment range is from 1 hour to
23 hours in the Automatic mode. To quickly
scroll through the timer values, press and
hold down the button.
NOTE : If you set the
timer to any value exceeding 23 hours, it
will be impossible to activate the Automatic
mode and if it was activated, the Automatic
mode will be deactivated.
3. Activate the Automatic mode by simultane
ously pressing down the two buttons for at
least 3 seconds. The Automatic mode icon
will appear. If the Automatic mode was al
ready activated, the same procedure should
be used to deactivate it.
4. When the adjustment is completed, release
the buttons and wait for 5 seconds to exit the
adjustment function.
NOTE : It is always possible to manually
change the Day/Night mode during a 24-hour
cycle. However, any manual return to the Night
mode will re-initialize the Night mode timer to
the latest value recorded, which modifies the
cycle in progress. In all cases, at the end of
the 24-hour cycle, the thermostat will return
to the Night mode and start a new cycle. It is
thus not necessary to readjust the Automatic
mode when a manual change is made to the
Day/Night mode.