9
InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2
Framed modules
The listed mounting variants are valid for point mounting and linear mounting.
* TestLoad=γ
m
x Design Load
γ
m
≥1.5(observeregionalrequirements)
clamp area [x]
Substructure lateral
Point mounting
clamp area [x]
Substructure longitudi-
nal Linear mounting
Design load
Permissible static
load [Pa]
Test load with
safety factor
γ
m
=1.5 [Pa]*
150 mm - 250 mm
−
3,600
1,600
5,400
2,400
125 mm - 275 mm
150 mm - 275 mm
2,900
1,600
4,400
2,400
100 mm - 300 mm
100 mm - 325 mm
2,250
1,600
3,400
2,400
75 mm - 325 mm
75 mm - 350 mm
1,600
1,600
2,400
2,400
clamp area [x]
Substructure lateral
Point mounting
clamp area [x]
Substructure longitudi-
nal Linear mounting
Design load
Permissible static
load [Pa]
Test load with
safety factor
γ
m
=1.5 [Pa]*
40 mm - 100 mm
−
2,250
1,600
3,400
2,400
40 mm - 160 mm
40 mm - 160 mm
1,600
1,600
2,400
2,400
clamping area Substructure
2 plannIng
x
x
x