5.3. Maintenance and inspection of hob  components. 

If the hob is operated in accordance with 

these instructions, cleaned and maintained according to the description presented in sub-clause 4.1, 
- then a hob that works properly does not require inspection. 
 

6.   HANDLING DEFECTS – error signaling 
 

Please read the following guidelines before calling the manufacturer’s service technician: 

-

 The reheating pad heats up but does not glow during operation of the burner pad.

 

 

Regular bursting noise of spark generator and valve can be heard while starting up the heating 

pad  before  gas  is  lit.  Individual  hot  field  may  glow  with  varying  power.  These  occurrences  and 
sounds  are  normal  in  an  operating  hob.  The  burner  located  under  the  hot  field  controls  its 
temperature  through  switching  on  and  off.  When  low  heating  power  setting  is  chosen  for  the  hot 
field, the burner will go off for a longer time, or for a shorter time in case of higher heating power, 
accordingly. In case of gas pressure drop in the network or cylinder, the hob will be automatically 
locked. This is signaled by the letter 

“G”

 
 

7.   CONTROLLER ALARM CONDITIONS SIGNALING

 

 
Alarm messages may display as a result of faults in hob operation, or gas shortage in network. 
 
 
 Identifications of alarm conditions and controller’s signals are given in Table 4. 
 

Table 4.

Reason

 

identification

 

 Condition signal

 

 flame  presence  signal  after 
switching on the valve

 

 Alarm G

 

Letter 

"G” 

on  controller  indicators, 

showing  in  the  field  corresponding  to 
the burner without flame.

 

No  flame  decay  signal  after 
switching  off  the  gas  valves. 
Flame  decay  waiting  time  is  5 
seconds.

 

Alarm C

 

Letter 

"C” 

on  the  controller  display  at 

the  burner  where  flame  decay  was  not 
observed.  The  controller  is  locked  and 
the gas supply is shut down.

 

Overheated 

controller, 

no 

ventilation, 

or 

concealed 

combustion gas outlet. 
 
Spill over alarm 

 Alarm D 
 
 
 
Alarm E

 

Letter 

“D” 

on  controller  display.  It 

remains  until  the  hob  cools  down  to 
working temperature. 
 
A  liquid  spilled  over  or  any  two  touch 
fields  were  activated  at  the  same  time 
(for example when cleaning the glass) 

    
 

 
 
 
 
 
 

Additional information: 

Содержание GPC-3

Страница 1: ...Sp z o o e mail biuro solgaz com pl Assembly and operating instructions OF CERAMIC GAS HOB for kitchen furniture arrangement GPC 3 GPC 3 T ...

Страница 2: ...tal friendly parameters which you will be able to evaluate in the course of daily use Have fun with preparing your perfect tasty meals Yours sincerely SOLGAZ The ceramic gas hob must be connected to a gas source by an authorized person certified installer Dear Sir Dear Madam We guarantee that your new gas fired heating panel will operate correctly However should you have any problems with using th...

Страница 3: ...ng function 10 3 4 Switching off the burners 11 3 5 Switching the controller lock on and off 11 3 6 Residual heat indicator 11 3 7 Choice of dishes 12 3 8 Utilization of combustion gas heat 12 3 9 Reduction of operating time 12 4 HOB CLEANING AND MAINTENANCE 13 4 1 Cleaning the ceramic plate 12 4 2 Cleaning the hob grids 13 4 3 Control and supervision over gas electrical and ventilation systems 13...

Страница 4: ...ge V 230 V 50 Hz Parameters of the power adapter 12V DC 3 5A Protection class of the housing IP 40 Dimensions L x W x D mm 600x495x110 The entire electrical installation of the hob is supplied with a special power pack and is prepared as a low voltage system In terms of fire risk the hob is classified as a safe device 1 3 Design of the gas hob The hob fig 1 has three injector gas burners rated as ...

Страница 5: ...Timer indicator 2 REQUIREMENTS FOR HOB INSTALLATION All activities related to hob installation and connection to gas and electrical system should be performed by a certified installer NOTE Before installing the hob and connecting it to the gas installation make sure it is adapted for the right type of gas supply and that this gas corresponds to the gas type given on the hob s rating plate by defau...

Страница 6: ...A composite kitchen countertop where the gas hob is to be installed must be permanently fixed to the cabinets or permanently connected with other elements of the furniture In order to place the hob in the kitchen countertop or in a composite countertop it is necessary to make an opening in it with the following dimensions depending on the type of the hob 540x465 mm If the hob is to be installed ov...

Страница 7: ...b with oven arrangement 1 VENTILATION AIR INLET IN THE BOTTOM PART OF THE SHELF 2 VENTILATION AIR INLET WITH MESH 3 AIR REMARKS Due to the height of the hob it is impossible to install it over an oven in standard kitchen cabinets If the kitchen cabinet has a back wall it is absolutely necessary to cut out ventilation openings in it as shown on the drawing fig 5 ...

Страница 8: ...m above the top plane of the hob plate away from the area affected by hot fumes exhausted in the back of the hob Moreover it is necessary to provide properly ventilated place for the power supply In other places a special cable to connect the hob with a 12 V DC system will provided on request 3 USE OF THE HOB 3 1 The startup of the hob should be performed by an authorized technician in the buyer s...

Страница 9: ...you will reduce the power setting The row of LEDs will simultaneously become shorter and the numbers displayed are lower to finally reach 0 9 corresponds to the maximum heating power of the burner and 0 corresponds to no power set After 1 to 3 seconds the burner will start burning gas the ceramic insert under the heating plate will turn red when fully heated You may also vary the burner power in a...

Страница 10: ...l is hot in the location of the burner that has just been shut down You may also switch off the entire hob To do so touch the main shutdown switch sensor or press and hold the power setting slider around zero power for some time having previously activated the selected sensor for switching down the burner All working burners will go off and those just shut down will display the letter H 3 5 Switch...

Страница 11: ...e bottom like grains of sand or remnants of cleaning agents NOTES for obvious reasons you are not allowed to use plastic dishes use aluminum dishes put empty dishes on the hob s heating fields when a burner is working Do not put dishes on or do not block the combustion gas outlet grate at the back of the hob particularly when it is working 3 8 Utilization of combustion gas heat The GPC 3 ceramic g...

Страница 12: ...rp scrubber The surface should then be wiped with a damp cloth with special protective agent Removing stains Light stains with a pearly color aluminum residue can be removed from a cold ceramic plate with a special cleaning agent Calcium residues caused e g by boiling water can be removed with vinegar or a special cleaning agent When removing sugar food leavings containing sugar plastics or alumin...

Страница 13: ...orms to the requirements of standards size dimensions location of hob the gas and electrical installations are built in accordance with valid standards and regulations Note After installing the hob the installer must carry out initial startup During initial startup squealing can be heard at combustion gas outlet This is normal caused by gas feeding to gas tubes and burner It will disappear after f...

Страница 14: ...ccordingly In case of gas pressure drop in the network or cylinder the hob will be automatically locked This is signaled by the letter G 7 CONTROLLER ALARM CONDITIONS SIGNALING Alarm messages may display as a result of faults in hob operation or gas shortage in network Identifications of alarm conditions and controller s signals are given in Table 4 Table 4 Reason identification Condition signal f...

Страница 15: ...er with your hob Power supply adapter Our service center s phone no 48 074 856 52 88 serwis solgaz com pl correspondence address SOLGAZ Sp z o o 58 124 Marcinowice ul Spoldzielcza 3 Poland TYPE GPC 3 SERIAL NUMBER INSTALLERS SIGNATURE DATE ...

Отзывы: