background image

 

 

 
 
 

 

1. 

ON/OFF 

- Press the  

  

button to turn the A/C on or off. When the unit is turned off, the Timer function 

will be cancelled. The set temperature will be saved. 

 

2. 

MODE SELECTION 

- Press the MODE button repeatedly to cycle between the different modes: Auto, 

Cool, Dry (Dehumidifier), and Fan. 

 

3. 

TEMPERATURE SETTING 

- Press the 

▼ 

button to decrease the temperature when the unit is on. 

Stop pressing the button when the desired temperature is displayed. Temperature range is 61

F-90

F. 

Press the 

▲ 

button to increase the temperature when the unit is on. Stop pressing the button when the 

desired temperature is displayed. Temperature range is 61

F-90

F. 

 

4. 

FAN 

- Press the FAN button to turn on the fan mode. 

FAN HIGH 

–Press this button to set the fan speed to high. Can be used in COOL or FAN mode. 

FAN MED 

–Press this button to set the fan speed to medium. Can be used in COOL or FAN mode. 

FAN LOW 

–Press this button to set the fan speed to low. Can be used in COOL or FAN mode. 

 

5. 

SLEEP MODE 

- Sleep mode can be activated under Cool mode, Dry mode, Auto mode, and Fan 

mode. Press the SLEEP button on the remote control, When in SLEEP mode, the fan will run on low to 
keep fan noise at a minimum. The temperature setting will gradually increase to 2°F above the original 
set temperature for each of first 2 hours. The unit will keep operating the same temperature until the 
sleep mode is turned off. 

 

6. 

ENERGY SAVER 

- Press the ENERGY SAVER button to turn on Energy Saver mode. When the unit 

is in Energy Saver mode, the energy saver light will turn on. Selecting Energy Saver mode will cycle 
the fan off and on with the compressor to limit energy consumption. Use this feature when the room is 
unoccupied and a greater range of room temperature is acceptable. 

 

7. 

TIMER 

- Press the TIMER button when the unit is off to set up the Auto-on timer. The hour indicator on 

the digital display will start flashing. Press the Timer

 

button to set timer within 1-24 hours. 

Press the TIMER button when the unit is on to set up the Auto-off timer. The hour indicator on the digi- 

tal display will start flashing. Press Timer

 

button to set timer within 1-24 hours. To cancel the timer, 

press the TIMER button repeatedly until the timer mode is off. 

 

8. 

°C 

/

°F - 

Press the 

°C 

/

°F 

button to switch the temperature between Celsius and Fahrenheit. 

 

9. 

MYTEMP MODE 

- Press the MYTEMP MODE button to change the thermostat sensor from the air 

conditioner to the remote location. When Mytemp mode is activated, current set temperature will flash 
3 seconds on digital display. The air conditioner will cool the area depending on the location and set 
temperature of the remote control. Take the remote control with you so the air conditioner cools the 
room to your location. 

 

10. 

CHILD LOCK 

- Press this button to lock/unlock the remote control buttons. 

 
 
 
 
 
 
 
 
 
 
 
 

OPERATING INSTRUCTIONS 

Содержание WM1-06E-01

Страница 1: ...Models WM1 06E 01 WM1 08E 01 WM1 10E 01 WM1 12E 01 6 400 BTU 8 500 BTU Electronic Window Air Conditioner Operating Instructions V170103 WM1 12E2 01 10 200BTU 12 600BTU...

Страница 2: ...ortant to us Please pay attention to all safety messages outlined in this owner s manual WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow the follow...

Страница 3: ...etal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Press TEST Button circuit...

Страница 4: ...Long Screw Curtain Lock Sash Lock Part List Window Air Conditioner 1 Remote Control 1 AAA Batteries 2 Top Mounting Rail 1 Insert Strip 1 Short Screw 8 Curtain 2 Sash Lock 2 Foam Seal 1 Long Screw for...

Страница 5: ...difying Capacity 31 Pints per day 35 Pints per day Product Dimensions W x H x D 18 625 x 12 625 x 15 5 19 x 14 375 x 19 5 Package Dimensions W x H x D 23 x 15 x 18 625 22 5 x 17 x 21 5 Net Gross Weigh...

Страница 6: ...NT TEST TO THE INFORMA TION AND THE SPECIFICATIONS PRESENTED HEREWITHIN WARNING Avoid fire hazard or electronic shock DO NOT use an extension cord or an adapter plug DO NOT remove any prong from the p...

Страница 7: ...attach a board or piece of wood to the sill The board or wood piece should have a depth of at least 1 1 2 Make sure the board or piece of wood is approximately 1 2 higher than the storm window frame T...

Страница 8: ...6 This is necessary for proper condensation utilization and drainage If you are not using the side panels the rear pitch must still be maintained 1 Attach the top rail onto the top of the outer case u...

Страница 9: ...m side when installed 4 Place the curtain lock between the curtain extensions and the window sill drive long screws through the lock and into the sill as shown below Foam Seal Sash Lock 3 Using a shar...

Страница 10: ...en windows and unscrew sash lock 3 Remove the screws installed through the frame and frame lock 4 Close slide the side panels into frame 5 Keeping a firm grip on air conditioner raise the sash and car...

Страница 11: ...n to change the fan speed Choose between high medium and low 6 Mode Button Press the MODE button to cycle through the various modes Auto Sleep Energy 7 Auto on Timer When the air conditioner is off it...

Страница 12: ...Battery Size AAA NOTE Do not mix old and new batteries or different types of AAA batteries LCD Display MODE SLEEP FAN HIGH ENERGY SAVER FAN MED TIMER FAN LOW C F CHILD LOCK MYTEMP MODE REMOTE CONTROL...

Страница 13: ...ep operating the same temperature until the sleep mode is turned off 6 ENERGY SAVER Press the ENERGY SAVER button to turn on Energy Saver mode When the unit is in Energy Saver mode the energy saver li...

Страница 14: ...Energy Saver mode is ON the fan will cycle on and off with the compressor This re sults more winder variations of room tempera ture and humidity Normally it is used when the room is occupied The fan...

Страница 15: ...nditioner may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid soap Rinse thoroughly with a damp cloth and wipe dry Never use harsh cleaners...

Страница 16: ...engaged discontinue use of the air conditioner and contact a qualified service technician The Air Conditioner does not cool as it should Airflow is restricted Make sure there are no curtains blinds o...

Страница 17: ...ghtly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan This is normal for a short period in areas with...

Страница 18: ...al handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those auth...