background image

 

 

 

 

 

Window Preparation 

Please read all instructions prior to installing your air conditioner. Two people are recommended to install this product. If 
a new electrical outlet is required, have the outlet installed by a qualified electrician before installing the unit. 

 

Before installing the unit, check the dimensions of your window to make sure the air conditioner will fit. This unit is made 
to fit inside a standard double-hung window. Make sure the window is in good shape and able to firmly hold the needed 
screws. If not, make repairs prior to installing the unit. 

 

 

Model 

WM1-06E-01 

WM1-08E-01 / WM1-10E-01  WM1-12E2-01 

Unit Height 

 12 5/8

 

18 5/8 

14 3/8" 

14 3/8" 

Unit Width 

18 5/8

 

13 

19" 

19"  

Min.Window Opening(See FIG 1)  13 1/4

 

14 3/4" 

14 3/4" 

Min. Window Width 

22 1/4" 

22 1/2" 

22 1/2" 

Max Window Width 

38

 

36 7/8" 

36 7/8" 

 
 

 

Storm Window Requirements 

A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly. To 
adjust for this, attach a board or piece of wood to the sill. The board or wood piece 

should have a depth of at least 1 1/2”. 

Make sure the board or piece of wood is approximately 1/2” higher than the storm window frame. This will allow the air 
conditioner to tilt enough for proper drainage. (See FIG. 2). 

 
 
 
 
 

 

13 1/4",14 3/4" MIN 

 
 
 
 
 
 
 
 
 
 
 

 

FIG. 1 

 

 

Prior to Installing the Air Conditioner 

1.  Check for anything that could block airflow. Check the area outside of the window for things such as shrubs, trees, or 

awnings. Check the inside area to make sure curtains, drapes, or blinds will not prevent proper airflow. 

2.  Check the available electrical outlet. The power supply must be the same as shown on the unit serial nameplate 

(located on the left side of the unit, near the front faceplate). Be sure the outlet is close enough for the power cord to 
reach. 

3.  Carefully unpack the air conditioner. Remove all packing material and make sure the floor is protected when remov- 

ing. Due to the large size of this air conditioner, two people should move the unit together. 

 

 

When handling the unit, be careful to avoid cuts from 
the sharp metal edges and aluminum fins on the front 
and rear coils. 

13 1/4",14 3/4" MIN 

FIG .2 

INSTALLATION 

Содержание WM1-06E-01

Страница 1: ...Models WM1 06E 01 WM1 08E 01 WM1 10E 01 WM1 12E 01 6 400 BTU 8 500 BTU Electronic Window Air Conditioner Operating Instructions V170103 WM1 12E2 01 10 200BTU 12 600BTU...

Страница 2: ...ortant to us Please pay attention to all safety messages outlined in this owner s manual WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow the follow...

Страница 3: ...etal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Press TEST Button circuit...

Страница 4: ...Long Screw Curtain Lock Sash Lock Part List Window Air Conditioner 1 Remote Control 1 AAA Batteries 2 Top Mounting Rail 1 Insert Strip 1 Short Screw 8 Curtain 2 Sash Lock 2 Foam Seal 1 Long Screw for...

Страница 5: ...difying Capacity 31 Pints per day 35 Pints per day Product Dimensions W x H x D 18 625 x 12 625 x 15 5 19 x 14 375 x 19 5 Package Dimensions W x H x D 23 x 15 x 18 625 22 5 x 17 x 21 5 Net Gross Weigh...

Страница 6: ...NT TEST TO THE INFORMA TION AND THE SPECIFICATIONS PRESENTED HEREWITHIN WARNING Avoid fire hazard or electronic shock DO NOT use an extension cord or an adapter plug DO NOT remove any prong from the p...

Страница 7: ...attach a board or piece of wood to the sill The board or wood piece should have a depth of at least 1 1 2 Make sure the board or piece of wood is approximately 1 2 higher than the storm window frame T...

Страница 8: ...6 This is necessary for proper condensation utilization and drainage If you are not using the side panels the rear pitch must still be maintained 1 Attach the top rail onto the top of the outer case u...

Страница 9: ...m side when installed 4 Place the curtain lock between the curtain extensions and the window sill drive long screws through the lock and into the sill as shown below Foam Seal Sash Lock 3 Using a shar...

Страница 10: ...en windows and unscrew sash lock 3 Remove the screws installed through the frame and frame lock 4 Close slide the side panels into frame 5 Keeping a firm grip on air conditioner raise the sash and car...

Страница 11: ...n to change the fan speed Choose between high medium and low 6 Mode Button Press the MODE button to cycle through the various modes Auto Sleep Energy 7 Auto on Timer When the air conditioner is off it...

Страница 12: ...Battery Size AAA NOTE Do not mix old and new batteries or different types of AAA batteries LCD Display MODE SLEEP FAN HIGH ENERGY SAVER FAN MED TIMER FAN LOW C F CHILD LOCK MYTEMP MODE REMOTE CONTROL...

Страница 13: ...ep operating the same temperature until the sleep mode is turned off 6 ENERGY SAVER Press the ENERGY SAVER button to turn on Energy Saver mode When the unit is in Energy Saver mode the energy saver li...

Страница 14: ...Energy Saver mode is ON the fan will cycle on and off with the compressor This re sults more winder variations of room tempera ture and humidity Normally it is used when the room is occupied The fan...

Страница 15: ...nditioner may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid soap Rinse thoroughly with a damp cloth and wipe dry Never use harsh cleaners...

Страница 16: ...engaged discontinue use of the air conditioner and contact a qualified service technician The Air Conditioner does not cool as it should Airflow is restricted Make sure there are no curtains blinds o...

Страница 17: ...ghtly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan This is normal for a short period in areas with...

Страница 18: ...al handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those auth...

Отзывы: