Auto Mode 

1)  Install the exhaust hose and window kit properly (see pages 7  & 8 ). 
2)  Plug the Power Cord into an electrical outlet. 
3)  Turn on the unit by pressing the 

POWER 

button. 

4)  Press the 

MODE 

button until the 

Auto mode 

indicator

 

appears on the control panel display.   

NOTE: 

During A

XWR

 mode, the unit operates in F

DQ

 

mode when the room temperature is below 

73 °F, and

Air Conditioner mode when the room temperature is above 73 °F. 

      

 
 
 
CONDENSATE EVAPORATION 
 
Emergency Condensate Holding Tank 

 

When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to 
evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emer-
gency condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automati-
cally shut off and the control panel with display “Ft” (Full Tank). To empty the condensate tank, pull the 
drain plug at the bottom back of the unit. You will need a small pan, approximately 1” high to catch the 
water coming out of the condensate tank. Connect the supplied drainage hose to the back of the unit to aid 
in drainage into the pan. Once the condensate tank is drained, the unit will begin working within a few 
minutes. The emergency condensate tank is approximately 1.5 Liters of water. Another option is to pur-
chase a small hose from a hardware store that can fit around the 9/16” drain plug on the back of the unit 
and drain the unit into a gravity drain or larger pan for continuous drainage. It is not advised to use continu-
ous drainage when the room temperature is higher than 90

°

F . 

 
The unit, along with the fan will automatically shut off when the unit displays “Ft” (Full Tank).

 

 

 

To resume operation quickly, empty the water container according to the following steps: 
1.  Do not move the unit when the water container is full. 
2.  Place the drain pan accessory under the drainage port at the back of the unit. 
3.  Remove the rubber plug from the drain hole. The condensate water will drain out automatically. 
4.  When the drain pan is full, install the rubber plug back onto the drainage hole to stop the water flow. 
5.  Empty the drain pan. 
6.  Repeat steps 2-5 until all the water is emptied. 

NOTE: 

Once the water container has 

been emptied, install the rubber plug 
back onto the drain hole. It is not advised 
to use continuous drainage when the 
room temperature is higher than 90

°

F . 

Drain Hole 

Rubber Plug 

Содержание TM-PAC-08E3

Страница 1: ...8 000 10 000 12 000 BTU Portable Air Conditioner Operating Instructions Model No TM PAC 08E3 TM PAC 10E3 V140306 3119233 Model No TM PAC 12E4 ...

Страница 2: ... reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded power supply 5 Do not start or stop the unit by inserting or ...

Страница 3: ...Conditioner 1 Exhaust Hose 1 Exhaust Hose Connector 1 Window Kit Adapter 1 Window Kit Adapter Extension 1 Rubber Plug 2 Remote Control 1 AAA Batteries 2 Caster Lock 2 Window Kit Sliding Panels 3 Drainage Hose 1 Owner s Manual 1 PACKAGE CONTENTS SPECIFICATIONS The cooling capacity is measured at an ambient temperature of DB 86 F WB 78 F Noise level is measured at a distance of 3 28 ft away from the...

Страница 4: ...hock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet 2 Press TEST Button circuit should trip cutting power to the air conditioner 3 Press RESET button for use If test button is pressed and unit can still be turned on...

Страница 5: ...ound or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Press TEST Button circuit should trip cutting power to the air conditioner When this occurs 3 Press RESET button to restore power to the machine Once power is restored the LED light will turn on again ...

Страница 6: ...6 Air Filter 7 Carry Handle 8 Air Exhaust Hose Discharge Opening 9 Condensation Drain Hole 10 Power Cord 11 Product Manual Not Shown 12 Exhaust Hose 13 Exhaust Hose Connector 14 Window Kit Adapter 15 Remote Control 16 Caster Locks 17 Rubber Plug 18 Window Kit 19 Window Kit Adapter Extension 20 Drainage Hose ...

Страница 7: ... 4 6 ft long approximate length MOUNTING THE EXHAUST HOSE Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both ends of the exhaust hose approximately 6 inches Screw the window kit adapter onto one end of the exhaust hose counter clockwise Screw the exhaust hose connector onto the other end of the exhaust hose co...

Страница 8: ...8 WINDOW KIT INSTALLATION ...

Страница 9: ...s free from gaps and or air pockets when taking measurements 3 Insert the rubber plugs into the holes that correspond with the width that your window requires to ensure that there are no gaps or air pockets in the window kit assembly after installation 1 Parts A Panel B Panel with one exhaust hose opening C Panel without exhaust hose opening D Rubber plug to lock window kit in place ...

Страница 10: ...ature setting Af ter the temperature is set the unit will display this temperature setting until it is changed by the user The temperature indicator display shows temperature in Fahrenheit Press and hold the Mode button for 20 seconds to switch between Celsius and Fahrenheit 4 Bucket Full When the unit cannot evaporate the collected moisture fast enough the excess water will collect in a backup wa...

Страница 11: ...AY POWER BUTTON SLEEP BUTTON MODE BUTTON FAN SPEED OPERATING THE UNIT USING THE REMOTE CONTROL Remote Colors may differ from the image above SWING BUTTON TIMER TEMP DECREASE TIMER TEMP INCREASE C F BUTTON THIS BUTTON DOES NOT HAVE A FUNCTION ...

Страница 12: ...perature Press the or to select your desired temperature setting The temperature on the LCD dis play on the remote control will increase or decrease accordingly Pressing the C F button will change the temperature select between C and F 5 SLEEP MODE To set Sleep mode make sure the unit is in Air Conditioner mode Dehumidifying mode or Auto mode Press the SLEEP Button on the remote control the remote...

Страница 13: ...um will also improve the cool ing efficiency NOTE When the unit is running on air conditioning mode the exhaust hose is required and must be vented outside using the supplied window kit Dehumidifier Mode 1 Install the exhaust hose and window kit properly see pages 7 8 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER Button 4 Press the MODE button until the d...

Страница 14: ...unit to aid in drainage into the pan Once the condensate tank is drained the unit will begin working within a few minutes The emergency condensate tank is approximately 1 5 Liters of water Another option is to pur chase a small hose from a hardware store that can fit around the 9 16 drain plug on the back of the unit and drain the unit into a gravity drain or larger pan for continuous drainage It ...

Страница 15: ...y dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess w...

Страница 16: ...t hose correctly keeping it as short and free of curves as possible Check and remove anything obstructing air discharge During operation there is an unpleasant smell in the room Air filter is dirty Remove air filters clean and re install Air conditioner does not oper ate after restarting the unit The internal compressor safety de vice prevents the unit from being restarted until three minutes have...

Страница 17: ...17 SELF DIAGNOSIS SYSTEM MALFUNCTION CODES SELF DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions Error messages are displayed on the appliance display ...

Страница 18: ... parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Home Comfort Freight and Insurance cost for the warranty service Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS HOME COMFORT DISCLAIMS ANY LIABILITY FOR CONSEQUENT...

Отзывы: