background image

ASSEMBLY & INSTALLATION - THRU-THE-WALL (CONT.) 

 12 

Carefully measure and cut an opening with the following 
dimensions depending on your model (FIG. 1 & 2). 
 
WIDTH “X” = inside model plus twice the thickness of the 
framing material used. 
HEIGHT “Y” = inside model height plus twice the thickness 
of framing material used. 

 
 

 
 
 
 
 
 
 
 
 
 
 

4.   Build a wooden frame with the INSIDE dimensions of 

your model listed above (Measure twice). The frame 
depth should be the same as the wall thickness. Fill in 
extra space from the opening to the studs with wood 
spacers as shown below. 

5.  Nail the spacers to the studs. They should be flush with 

the dry wall.  

 

 

 
 

NOTE

: If wall thickness is 8-12” or more, add aluminum 

flashing over the bottom of the frame opening to assure 
water is unable to enter the area between the inner and 
outer wall. 

 

Prepare and Install the Cabinet

 

1.  Slide the chassis from the cabinet. Refer back to the 

REMOVE CHASSIS instructions and FIG. 1-6 in the 
WINDOW MOUNTING SECTION.  

2.  Place the cabinet into the opening with the bottom rail 

resting firmly on the bottom board of the wood frame. 

3.  Position the cabinet so it is tilted properly for water re-

moval as seen below. 

4.  Secure the bottom rail to the wood frame with two large 

1” (2.5 cm) long wood screws as shown below. 

 
 
 
 
 
 
 

Model SG-WAC-25HCE 

Inside Frame Height 

18 7/8” (47.9 cm) 

Inside Frame Width 

26 3/4” (67.9 cm) 

FIG. 2 

 

FIG. 1 

FIG. 2 

Содержание SG-WAC-25HCE

Страница 1: ...Model SG WAC 25HCE Electronic Heat Cool Window A C Operating Instructions...

Страница 2: ...ad this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outline...

Страница 3: ...e The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset Do not use the power supply cord as an ON OFF switch The power supply cord is d...

Страница 4: ...ch or Pliers Pencil Level Socket Wrenches Phillips Head Screwdriver Non Hardware Packing List Window Air Conditioner AAA Batteries 2 Top Mounting Rail Foam Top Mounting Rail Seal Strip Accordion Panel...

Страница 5: ...ent Cooling Amperage 12 13 EER 9 4 9 4 Noise Level dB A 60 CFM 510 Dehumidifying Capacity 192 Pints per day Product Dimensions W x H x D 26 5 x 18 625 x 26 5 Package Dimensions W x H x D 29 25 x 20 25...

Страница 6: ...to tilt enough for proper drainage See FIG 2 Prior to Installing the Air Conditioner 1 Check for anything that could block airflow Check the area outside of the window for things such as shrubs trees...

Страница 7: ...emove and place to the side 3 Locate the four faceplate screws and remove These screws will need to be re installed prior to mounting the air con ditioner FIG 2 above 4 After removing the screws gentl...

Страница 8: ...m the top of the unit and both sides of the cabinet if installed FIG 6 7 7 Hold the cabinet while pulling on the base handle to carefully remove the unit Do not pull or lift near the top of the unit F...

Страница 9: ...over the screws Top Angle Rail and Side Bracket Installation 1 Place the air conditioner on a hard flat surface 2 Locate the foam gasket and top angle rail 3 Attach the foam gasket to the top angle ra...

Страница 10: ...the cabinet as shown below 4 Tighten all 6 bolts securely Extend the Accordion Panels 1 Carefully raise the window to expose the accordion panel and panel frame Loosen the locking screws so the accord...

Страница 11: ...as specified below MAX WALL THICKNESS 8 1 4 IMPORTANT The side louvers must never be blocked NOTE All parts needed for Thru The Wall Installation are provided except a wood frame shims and 10 wood sc...

Страница 12: ...should be flush with the dry wall NOTE If wall thickness is 8 12 or more add aluminum flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and o...

Страница 13: ...STRUCTION 1 Cut or build a wall opening in the masonry wall similar to the frame construction refer to the THRU THE WALL installation for a wall thickness greater than 8 1 2 2 Secure the cabinet in pl...

Страница 14: ...an setting To set the Auto on Timer press the DELAY button on the unit or remote control Each touch of the on the unit or the buttons on the remote will change the timer setting in 1 hour intervals Th...

Страница 15: ...or to start and cooling to begin Heat Mode Use the Heat mode at Low Med High or Auto Fan Speed for heating Use the temperature buttons to set the desired temperature between 64 F and 86 F in 1 F incre...

Страница 16: ...to Cool and the Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool settin...

Страница 17: ...Tear To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from trippin...

Страница 18: ...e technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold...

Страница 19: ...oper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the b...

Страница 20: ...y wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service Filter and Accessories...

Отзывы: