INSTALLATION & ASSEMBLY INSTRUCTIONS 

Window Preparation

 

Please read all instructions prior to installing your air conditioner. Two people are recommended to install this product. If 
a new electrical outlet is required, have the outlet installed by a qualified electrician before installing the unit.  
 
Before installing the unit, check the dimensions of your window to make sure the air conditioner will fit. This unit is made 
to fit inside a standard double-hung window. Make sure the window is in good shape and able to firmly hold the needed 
screws. If not, make repairs prior to installing the unit.  
 
 
 
 
 

 

 
 
 
 

Storm Window Requirements 

A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly. To 
adjust for this, attach a board or piece of wood to the sill. The board or wood piece should have a depth of at least 1 1/2”. 
Make sure the board or piece of wood is approximately 1/2” higher than the storm window frame. This will allow the air 
conditioner to tilt enough for proper drainage. (See FIG. 2). 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 

Prior to Installing the Air Conditioner 

1.  Check for anything that could block airflow. Check the area outside of the window for things such as shrubs, trees, or 

awnings. Check the inside area to make sure curtains, drapes, or blinds will not prevent proper airflow. 

2.  Check the available electrical outlet. The power supply must be the same as shown on the unit serial nameplate 

(located on the left side of the unit, near the front faceplate). Be sure the outlet is close enough for the power cord to 
reach. 

3.  Carefully unpack the air conditioner. Remove all packing material and make sure the floor is protected when remov-

ing. Due to the large size of this air conditioner, two people should move the unit together.  

 
 

 6 

Model SG-WAC-25HCE 

Unit Height 

18 5/8” 

Unit Width 

26 1/4” 

Min. Window Opening (See 
FIG 1) 

19 1/2” 

Min. Window Width 

30” 

Max Window Width 

41” 

FIG. 1 

When handling the unit, be careful to avoid cuts from 
the sharp metal edges and aluminum fins on the front 
and rear coils. 

FIG. 2 

Board or wood piece must 
be approximately 1/2” higher 
than the storm window frame 
for proper drainage 

Storm window frame 
or obstruction 

SASH 

Storm window frame or 
obstruction 

SASH 

Содержание SG-WAC-25HCE

Страница 1: ...Model SG WAC 25HCE Electronic Heat Cool Window A C Operating Instructions...

Страница 2: ...ad this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outline...

Страница 3: ...e The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset Do not use the power supply cord as an ON OFF switch The power supply cord is d...

Страница 4: ...ch or Pliers Pencil Level Socket Wrenches Phillips Head Screwdriver Non Hardware Packing List Window Air Conditioner AAA Batteries 2 Top Mounting Rail Foam Top Mounting Rail Seal Strip Accordion Panel...

Страница 5: ...ent Cooling Amperage 12 13 EER 9 4 9 4 Noise Level dB A 60 CFM 510 Dehumidifying Capacity 192 Pints per day Product Dimensions W x H x D 26 5 x 18 625 x 26 5 Package Dimensions W x H x D 29 25 x 20 25...

Страница 6: ...to tilt enough for proper drainage See FIG 2 Prior to Installing the Air Conditioner 1 Check for anything that could block airflow Check the area outside of the window for things such as shrubs trees...

Страница 7: ...emove and place to the side 3 Locate the four faceplate screws and remove These screws will need to be re installed prior to mounting the air con ditioner FIG 2 above 4 After removing the screws gentl...

Страница 8: ...m the top of the unit and both sides of the cabinet if installed FIG 6 7 7 Hold the cabinet while pulling on the base handle to carefully remove the unit Do not pull or lift near the top of the unit F...

Страница 9: ...over the screws Top Angle Rail and Side Bracket Installation 1 Place the air conditioner on a hard flat surface 2 Locate the foam gasket and top angle rail 3 Attach the foam gasket to the top angle ra...

Страница 10: ...the cabinet as shown below 4 Tighten all 6 bolts securely Extend the Accordion Panels 1 Carefully raise the window to expose the accordion panel and panel frame Loosen the locking screws so the accord...

Страница 11: ...as specified below MAX WALL THICKNESS 8 1 4 IMPORTANT The side louvers must never be blocked NOTE All parts needed for Thru The Wall Installation are provided except a wood frame shims and 10 wood sc...

Страница 12: ...should be flush with the dry wall NOTE If wall thickness is 8 12 or more add aluminum flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and o...

Страница 13: ...STRUCTION 1 Cut or build a wall opening in the masonry wall similar to the frame construction refer to the THRU THE WALL installation for a wall thickness greater than 8 1 2 2 Secure the cabinet in pl...

Страница 14: ...an setting To set the Auto on Timer press the DELAY button on the unit or remote control Each touch of the on the unit or the buttons on the remote will change the timer setting in 1 hour intervals Th...

Страница 15: ...or to start and cooling to begin Heat Mode Use the Heat mode at Low Med High or Auto Fan Speed for heating Use the temperature buttons to set the desired temperature between 64 F and 86 F in 1 F incre...

Страница 16: ...to Cool and the Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool settin...

Страница 17: ...Tear To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from trippin...

Страница 18: ...e technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold...

Страница 19: ...oper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the b...

Страница 20: ...y wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service Filter and Accessories...

Отзывы: