background image

 
 
 

 

 

 
 
 
 
 
 
 

 

 

 10 

USING YOUR AIR CONDITIONER 

(Cont.) 

• 

Freezing Conditions: 

This is a cooling only air 

conditioner. It is not designed for freezing outdoor 
conditions. It must not be used in freezing outdoor 
conditions. 

• 

Remote Control: 

To ensure proper operation 

when using the remote control, aim the remote 
directly at the signal receiver on the air condi-
tioner. 

• 

The remote control has a signal range up to 
20 feet.   

• 

Make sure nothing is blocking the remote con-
trol signal from being received by the air con-
ditioner. 

• 

Make sure the batteries are installed correctly 
and still have power. 

• 

Cooling Mode: 

Use the COOL mode at Low, Me-

dium, High, or Auto Fan speed when cooling is 
needed. Use the temperature 

/

 buttons to set 

the desired temperature between 64°F and 86°F.  

• 

Once the temperature is set, the compressor 
will cycle on and off to keep the room 
temperature at the set temperature level. The 
lower the set thermostat temperature, the 
cooler the room will become. The higher the 
set thermostat temperature, the warmer the 
room will become. 

• 

For Normal Cooling - Set the Mode to 

Cool 

and the Fan to 

High 

or 

Med 

with the 

termperature set in the middle. 

• 

For Maximum Cooling - Set the Mode to 

Cool 

and the Fan to 

High 

with a lower set 

temperature. 

• 

For Quieter & Nighttime Cooling - Set the 
Mode to 

Cool 

and the Fan to 

Low 

with the 

temperature set in the middle. 

NOTE: 

If the air conditioner is off and is then 

turned on while set to a Cool setting or if 
turned from a fan setting to a Cool setting, it 
may take approximately 3 minutes for the 
compressor to start and cooling to begin. 

• 

Energy Saver Mode 

- Controls the Fan 

On 

- The fan will cycle on and off with the            

compressor. This results in winder variations of room 
temperature and humidity. Normally used with the 
room is unoccupied. NOTE: The fan my continue to 
run for a short time after the compressor cycles off. 

Off 

- The fan runs all the time in fan or cooling mode. 

 

• 

Fan Only Mode: 

Use 

Fan Only 

mode at 

Low

Med

, or 

High 

fan speed to provide air circulation 

and filtering without cooling. Since fan only setting 
do not provide cooling, a 

Set 

temperature cannot 

be entered. The room temperature will appear in 
the display.  

      NOTE: 

Auto Fan 

Speed cannot be used in 

Fan    

Only 

mode. 

• 

Loss of Power Protection: 

If power to the air 

conditioner is lost or interrupted, the air condi-
tioner will automatically re-start in the setting last 
used prior to power loss. If the Timer was set to 
automatically turn the air conditioner off or on, it 
will resume countdown at the amount time left 
prior to power loss. You may need to set a new 
time if desired. 

• 

Air Direction: 

Use the lever on the front air vents 

to adjust the direction of the airflow. You can di-
rect the airflow left, right, up or down. The lever is 
located on the right side of the air vent. 

 

Содержание SG-WAC-06ESE

Страница 1: ......

Страница 2: ......

Страница 3: ...ad this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outline...

Страница 4: ...set buttons on the LCDI Plug are used to check if the plug is functioning properly To test the plug 1 Plug power cord into a wall outlet 2 Press the TEST Button the circuit should trip and cut all pow...

Страница 5: ...Air Conditioner Remote Control AAA Batteries 2 Top Mounting Rail Top Mounting Rail Seal Strip 2 5 Screw for Top Mounting Rail 4 Accordion Panels Left Right Sash Lock 1 Window Sash Seal 3 4 Screw for...

Страница 6: ...ting Capacity BTU h Cooling Power Input Watts 620 Heating Power Input Watts Rated Current Cooling Amperage 5 6 Rated Current Heating Amperage EER C O P 9 7 Noise Level db A H L 56 61 CFM 180 Design Pr...

Страница 7: ...nsions 3 The Lower Sash the lower part of the window that moves up and down must allow for 13 5 of vertical clearance when open See FIG 1 4 All supporting parts must be secured to firm wood masonry or...

Страница 8: ...el about a 1 3 bub ble will be the correct case slant to the outside See FIG 5 FIG 6 2 Once the air conditioner is placed extend both the left and right accordion panels to the width of the window Acc...

Страница 9: ...e width of the window Insert the foam between the window sashes to prevent air and objects from getting into the room See FIG 13 Removing the Air Conditioner from the Window 1 Turn the air conditioner...

Страница 10: ...ing To set the Auto on Timer press the DELAY button on the unit or remote control Each touch of the on the unit or the buttons on the remote will change the timer setting in 1 hour intervals The SET l...

Страница 11: ...he Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take...

Страница 12: ...Tear To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from trippin...

Страница 13: ...e technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold...

Страница 14: ...is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture remo...

Страница 15: ...y wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service Filter and Accessories...

Страница 16: ...66129903754...

Отзывы: