background image

 
 
 

 

 

 

 

 

 

 

 

 

 

 

  

USING YOUR AIR CONDITIONER 

(Cont.) 

• 

Freezing Conditions: 

This is a cooling only air 

conditioner. It is not designed for freezing outdoor 
conditions. It must not be used in freezing outdoor 
conditions. 

• 

Remote Control: 

To ensure proper operation 

when using the remote control, aim the remote 
directly at the signal receiver on the air condi-
tioner. 

• 

The remote control has a signal range up to 
20 feet.   

• 

Make sure nothing is blocking the remote con-
trol signal from being received by the air con-
ditioner. 

• 

Make sure the batteries are installed correctly 
and still have power. 

• 

Cooling Mode: 

Use the COOL mode at Low, Me-

dium, High, or Auto Fan speed when cooling is 
needed. Use the temperature 

/

 buttons to set 

the desired temperature between 64°F and 86°F.  

• 

Once the temperature is set, the compressor 
will cycle on and off to keep the room 
temperature at the set temperature level. The 
lower the set thermostat temperature, the 
cooler the room will become. The higher the 
set thermostat temperature, the warmer the 
room will become. 

• 

For Normal Cooling - Set the Mode to 

Cool 

and the Fan to 

High 

or 

Med 

with the 

termperature set in the middle. 

• 

For Maximum Cooling - Set the Mode to 

Cool 

and the Fan to 

High 

with a lower set 

temperature. 

• 

For Quieter & Nighttime Cooling - Set the 
Mode to 

Cool 

and the Fan to 

Low 

with the 

temperature set in the middle. 

NOTE: 

If the air conditioner is off and is then 

turned on while set to a Cool setting or if 
turned from a fan setting to a Cool setting, it 
may take approximately 3 minutes for the 
compressor to start and cooling to begin. 

• 

Energy Saver Mode 

- Controls the Fan 

On 

- The fan will cycle on and off with the            

compressor. This results in winder variations of room 
temperature and humidity. Normally used with the 
room is unoccupied. NOTE: The fan m

a

y continue to 

run for a short time after the compressor cycles off. 

Off 

- The fan runs all the time in fan or cooling mode. 

 

• 

Fan Only Mode: 

Use 

Fan Only 

mode at 

Low

Med

, or 

High 

fan speed to provide air circulation 

and filtering without cooling. Since fan only setting 
do not provide cooling, a 

Set 

temperature cannot 

be entered. The room temperature will appear in 
the display.  

      NOTE: 

Auto Fan 

Speed cannot be used in 

Fan    

Only 

mode. 

• 

Loss of Power Protection: 

If power to the air 

conditioner is lost or interrupted, the air condi-
tioner will automatically re-start in the setting last 
used prior to power loss. If the Timer was set to 
automatically turn the air conditioner off or on, it 
will resume countdown at the amount time left 
prior to power loss. You may need to set a new 
time if desired. 

• 

Air Direction: 

Use the lever on the front air vents 

to adjust the direction of the airflow. You can di-
rect the airflow left, right, up or down. The lever is 
located on the right side of the air vent. 

 

 1

3

Содержание SG-WAC-06ESE-C

Страница 1: ...Models SG WAC 06ESE C SG WAC 08ESE C Electronic Window Air Conditioner Operating Instructions V 121017...

Страница 2: ......

Страница 3: ...ad this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outline...

Страница 4: ...hen the TEST button is pressed and the unit fails to reset Do not use the power supply cord as an ON OFF switch The power supply cord is designed as a protection device A damaged power supply cord mus...

Страница 5: ...nditioner Remote Control AAA Batteries 2 Top Mounting Rail Top Mounting Rail Seal Strip 2 5 Screw for Top Mounting Rail 4 Accordion Panels Left Right Sash Lock 1 Window Sash Seal 4 5 Screw for Window...

Страница 6: ...THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN Model SG WAC 06ESE C SG WAC 08ESE C Power Supply Ph V Hz 1 115...

Страница 7: ...3 The Lower Sash the lower part of the window that moves up and down must allow for 13 25 of vertical clearance when open See FIG 1 4 All supporting parts must be secured to firm wood masonry or metal...

Страница 8: ...proper condensation utilization and drainage If you are not using the side panels the rear pitch must still be main tained 1 Remove the backing from the top mounting rail seal strip and attach the sea...

Страница 9: ...ach the window air conditioner to the lower sash See FIG 8 Accordion Panel Installation Now that you have installed the top rail you can now install the accordion panels on each side 1 Place the air c...

Страница 10: ...oximately 1 2 higher than the storm window frame This will allow the air conditioner to tilt enough for proper drain age See FIG 12 Removing the Air Conditioner from the Window 1 Turn the air conditio...

Страница 11: ...ight will turn on while setting Auto off Timer When the air conditioner is on it can be set to automatically turn off in 0 5 24 hours To set the Auto off Timer press the TIMER button on the unit or re...

Страница 12: ...ner will cool the area depending on the location and set temperature of the remote control Take the remote control with you so the air conditioner cools the room to your loca tion The Remote must be i...

Страница 13: ...MODE and buttons at the same time 11 DISPLAY LIGHTS Hold the and FAN buttons to turn the light s on the display ON or OFF This can be done when the unit is on or off 12 ENERGY SAVER MODE When the unit...

Страница 14: ...Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take app...

Страница 15: ...ar To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping C...

Страница 16: ...ce technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Col...

Страница 17: ...r is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture rem...

Страница 18: ...ar Warranty service must be performed by a qualified HVAC contractor Soleus maintains a centralized service network to provide parts and assist in resolving service problems if difficulties are encoun...

Страница 19: ......

Страница 20: ......

Отзывы: