USING YOUR AIR CONDITIONER 

Electronic Control Panel & Remote Control 

 

 

 

 

1. 

Power Button: 

Turns the air conditioner on and 

off 

2. 

Digital Display: 

Under ON status without timer

setting,the operation mode is Auto,

 

Cool, Energy 

Saver or Dry mode,and the set temperature will be

displayed.

Under ON status without timer setting, the 

operation mode is fan mode and the ambient 

temperature

 will be displayed

.  

Time will be displaye

d

 under timer setting or timer

preview

 

 

3. 

Temperature Set: 

Use these buttons on the con-

trol panel and remote to increase or decrease the 
Set Temperature (the desired room temperature) 
in cooling

,

energy saver 

and dry 

mode. The 

SET

light 

will light up when setting the temperature 

4. 

Timer Set: 

Use these buttons on the control 

panel and remote to set the Timer. Each press of 
the Timer (

DELAY

) buttons will increase or de-

crease the timer. For timer instructions see #7. 

5. 

Fan Speed & Auto Fan

: Use the fan speed but-

tons to change the fan speed. Choose between 
low, medium, high, and Auto. 

                                      

6. 

Mode Button: 

Press the mode button to cycle 

through the various modes: Cooling, Energy 
Saver, Fan only, Dry (Dehumidifier)

 and Auto

7.  Auto-on Timer: 

When the air conditioner is off, it 

can be set to automatically turn on in 0.5-24 hours 
at the previous set mode and fan setting. To set 
the Auto-on Timer, press the 

TIMER 

button on the 

unit or remote control. 

The timer can be set in 0.5 

The Set light will turn on while setting.

 

Auto-off Timer: 

When the air conditioner is on, it 

can be set to automatically turn off in 0.5-24 
hours. To se

t

 the Auto-off Timer, press the 

TIMER 

button on the unit or remote control. 

The timer 

 

can be set in 0.5 hour increment below 10 hours

and in 1 hour increment for 10 hours or above.

The 

SET 

light will turn on while setting. 

• 

To see the remaining time, press the 

TIMER 

Button. To change the timer setting use the 

/

 on the unit or the +/- buttons on the 

remote. 

• 

   

During preview of timer or timer setting,

press Timer button on the panel or remote 

8. 

Filter Check: 

After the fan rotates for 250 total 

hours, the filter check light will turn on to remind 
the user to clean the filter. Press the Filter check 
button once the filter is cleaned to reset the re-
minder.

 

Air Conditioner Controls 

NOTE: This display always shows the room temperature

 in Fan 

 

Mode 

except when setting the Set temperature or the Timer

 

 

When the light is on the unit is in 

temperature or timer set mode. 

Normal Operating Sounds 

• 

You may hear a pinging noise caused by water 
hitting the condenser, on rainy days, or when the 
humidity is high. This design feature helps re-
move moisture and improve efficiency.  

• 

You may hear the thermostat click when the com-
pressor cycles on and off. 

• 

Water will collect in the base pan during rain or 
days of high humidity. The water may overflow 
and drip from the outside part of the unit. 

• 

The fan may run even when the compressor is 
not on. 

hour increment below 10 hours and in 1 hour

increment for 10 hours or above.

controller to cancel the timer setting.

 

10

 

Содержание SG-WAC-06ESE-C

Страница 1: ...Models SG WAC 06ESE C SG WAC 08ESE C Electronic Window Air Conditioner Operating Instructions V 121017...

Страница 2: ......

Страница 3: ...ad this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outline...

Страница 4: ...hen the TEST button is pressed and the unit fails to reset Do not use the power supply cord as an ON OFF switch The power supply cord is designed as a protection device A damaged power supply cord mus...

Страница 5: ...nditioner Remote Control AAA Batteries 2 Top Mounting Rail Top Mounting Rail Seal Strip 2 5 Screw for Top Mounting Rail 4 Accordion Panels Left Right Sash Lock 1 Window Sash Seal 4 5 Screw for Window...

Страница 6: ...THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN Model SG WAC 06ESE C SG WAC 08ESE C Power Supply Ph V Hz 1 115...

Страница 7: ...3 The Lower Sash the lower part of the window that moves up and down must allow for 13 25 of vertical clearance when open See FIG 1 4 All supporting parts must be secured to firm wood masonry or metal...

Страница 8: ...proper condensation utilization and drainage If you are not using the side panels the rear pitch must still be main tained 1 Remove the backing from the top mounting rail seal strip and attach the sea...

Страница 9: ...ach the window air conditioner to the lower sash See FIG 8 Accordion Panel Installation Now that you have installed the top rail you can now install the accordion panels on each side 1 Place the air c...

Страница 10: ...oximately 1 2 higher than the storm window frame This will allow the air conditioner to tilt enough for proper drain age See FIG 12 Removing the Air Conditioner from the Window 1 Turn the air conditio...

Страница 11: ...ight will turn on while setting Auto off Timer When the air conditioner is on it can be set to automatically turn off in 0 5 24 hours To set the Auto off Timer press the TIMER button on the unit or re...

Страница 12: ...ner will cool the area depending on the location and set temperature of the remote control Take the remote control with you so the air conditioner cools the room to your loca tion The Remote must be i...

Страница 13: ...MODE and buttons at the same time 11 DISPLAY LIGHTS Hold the and FAN buttons to turn the light s on the display ON or OFF This can be done when the unit is on or off 12 ENERGY SAVER MODE When the unit...

Страница 14: ...Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take app...

Страница 15: ...ar To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping C...

Страница 16: ...ce technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Col...

Страница 17: ...r is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture rem...

Страница 18: ...ar Warranty service must be performed by a qualified HVAC contractor Soleus maintains a centralized service network to provide parts and assist in resolving service problems if difficulties are encoun...

Страница 19: ......

Страница 20: ......

Отзывы: