PROBLEM

   

 

 

The Air Conditioner will not start
 

 

 
 
 
 
 
 
 
 

POSSIBLE CAUSES 

 

The air conditioner is unplugged 

 

 
 
The fuse is blown/circuit breaker is 
tripped. 

 
 

Power Failure 

 
 
 
 
 
 
 

The current interrupter device is 
tripped. 

SOLUTIONS 

 

• 

Make sure the air conditioner is 
plug is pushed completely into the 
outlet 

 

• 

Check the house fuse/circuit 
breaker box and replace the fuse 
or reset the breaker. 

 

• 

The unit will automatically re-start 
when power is restored. 

• 

There is a protective time delay 
(approx. 3 minutes) to prevent  
tripping of the compressor      
overload. For this reason, the unit 
may not start normal cooling for 3 
minutes after it is turned back on. 

 

• 

Press the RESET button located 
on the power cord plug. 

• 

If the RESET button will not stay 
engaged, discontinue use of the 
air conditioner and contact a   
qualified service technician.

 

TROUBLESHOOTING 

The Air Conditioner does not cool 
as it should 

 

 
 
 
 
 
 
 
 

Airflow is restricted 

 

 
 
The temperature control may not be 
set correctly. 

 

The air filter is dirty 

 
 

The room may be too warm 
 
 
 
Cold air is escaping 
 
 
The Cooling Coils are frozen 

• 

Make sure there are no curtains, 
blinds, or furniture blocking the 
front of the air conditioner 

 

• 

Turn the TEMP dial to a higher 
number 

 

• 

Clean the filter. See the Cleaning 
and Care Section of the manual. 

 

• 

Please allow time for the room to 
cool down after turning on the air 
conditioner. 

 

• 

Check for open furnace registers 
and cold air returns

 

 

• 

See “Air Conditioner Freezing Up” 
below. 

The Air Conditioner is freezing up 

 

Ice blocks the air flow and stops the air 
conditioner from cooling the room 

• 

Set the MODE dial to HIGH FAN 
or HIGH COOL and set the TEMP 
dial to 1 or 2 

The Remote Control is not working 
(if included with your air condi-
tioner) 

The batteries are inserted incorrectly 
 
The batteries may be dead 

• 

Check the position of the batteries.    

 

• 

Replace the batteries 

 10 

Содержание SG-WAC-05SM

Страница 1: ...5 000 BTU Window Air Conditioner Operating Instructions Model No SG WAC 05SM...

Страница 2: ...ad this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outline...

Страница 3: ...set buttons on the LCDI Plug are used to check if the plug is functioning properly To test the plug 1 Plug power cord into a wall outlet 2 Press the TEST Button the circuit should trip and cut all pow...

Страница 4: ...ack of the unit DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT...

Страница 5: ...ssembled prior to installing the air conditioner in the window Tools Needed Phillips Screw Driver Attaching the Top Rail to the Air Conditioner 5 Top Rail Hardware QTY 4 1 3 8 Screw Top Panel 1 Remove...

Страница 6: ...el about a 1 3 bub ble will be the correct case slant to the outside See FIG 5 FIG 6 2 Once the air conditioner is placed extend both the left and right accordion panels to the width of the window Acc...

Страница 7: ...h lock and a 3 4 screw as shown below See FIG 12 4 For added insulation cut the supplied insulation foam to the width of the window Insert the foam between the window sashes to prevent air and objects...

Страница 8: ...lest 5 Directional Louvers To direct the airflow rotate the small vertical louver wheel next to the air vent on the front of the air conditioner NOTE To minimize wear and tear on the air conditioner a...

Страница 9: ...ot wish to wash the filter you may vacuum the filter to remove the dust and other particles Cabinet Cleaning To clean the air conditioner cabinet Unplug the air conditioner to prevent shock or a fire...

Страница 10: ...n TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold air is esc...

Страница 11: ...is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture remo...

Страница 12: ...y wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service Filter and Accessories...

Отзывы: