background image

 14 

REMOTE CONTROL OPERATING INSTRUCTIONS 
 

1) 

Power On and Off 

- Press the 

POWER (

I/O

button once to manually turn the unit on. Press the Power 

button once more to turn the unit off.  When you press the 

POWER 

button the upper right square on the 

remote control LED Display will light up. When in Air Conditioner and Auto mode, the selected tempera-
ture will appear on the remote control display. When the unit is in Fan mode and Dehumidifier mode you 
will see the “- -” icon instead of the set temperature. This shows that temperature selection is not available 
when the unit is in Fan or Dehumidifier mode. 

2) 

Mode Selection 

- Press the 

MODE

 Button repeatedly to cycle between the different modes: Auto, Air 

Conditioner, Dehumidifier, Fan only, and Heater mode. The upper left square on the Remote control dis-
play will light up showing which mode is selected. In Air Conditioner mode the display will show 

COOL

”, in  Heating mode the display will show “

HEAT

”, in Dehumidifier mode the display will show 

DRY

”, in Fan mode the display will show “

FAN

”, and in Auto mode the display will show “

AUTO

”. 

3) 

Fan Speed 

- Press the 

FAN 

speed button to cycle through high, medium, and low fan speeds. The dis-

play on the remote control will show HIGH, MED, & LOW under the “SPEED” label on the remote con-
trol LCD display. There is an additional 

auto 

speed setting that is enabled in only heating and cooling 

modes. This speed is next setting after low when pressing the 

FAN 

speed button on the remote control. 

The speeds will cycle through in this order: 

High, Medium, Low, Auto

. Each change in speed will be as-

sociated with a “beep” sound from the unit. The remote control will not display “AUTO” under the speed 
label. Once Auto fan speed is selected the unit will beep and there will not be a fan speed displayed on the 
remote control. 

4) 

Temperature Setting 

- When the unit is in Air Conditioner or Heating mode you can select your desired 

temperature. Press the 

 or 

 to select your desired temperature setting. The temperature on the LCD dis-

play on the remote control will increase or decrease accordingly.  Pressing the 

and 

 buttons simultane-

ously will change the temperature select between °F and °C.  

5) 

SLEEP MODE  

- See “SLEEP MODE” on page 12. 

6) 

SWING

 - To turn on oscillation, press the 

SWING 

button on the remote control. Once you press 

SWING 

button, 

the louvers on the unit will oscillate up and down “    ” . To change the horizontal direction of the 

air flow manually adjust the internal horizontal louvers left or right. Once 

SWING 

is selected the “        “ 

icon will show up on the LCD display on the remote control. 

7) 

CLOCK 

- To set the clock on the remote control, hold down either the 

MIN 

or 

HOUR 

button until the 

displayed time flashes on the remote control display. Change the minutes by pressing the 

MIN 

button and 

change the hours by pressing the 

HOUR 

button. Set the clock prior to programming the timer. 

8) 

TIMER 

- After setting the clock, you are ready to program the timer. program the timer, first press the 

T-

ON 

button when the unit is off. Once 

T-ON 

is pressed the auto-on timer will blink in the bottom right rec-

tangle of the remote control display. Press the 

MIN

 

and 

HOUR 

buttons to change the clock to the desired 

time for the unit to automatically turn on.  The minutes will increase by 10 with each press of the 

MIN 

but-

ton and the hours will increase by 1 with each press of the 

HOUR 

button. Press the 

T-OFF 

button when 

the unit is on to set the off timer. The remote control display will flash the desired auto-off timer.  Press the 

MIN

 

and 

HOUR 

buttons to change the clock to the desired time for the unit to automatically turn off.  The 

timer is set when the auto-off time stops flashing and the words “ON” and “OFF” are displayed next to the 
time.  

Содержание PH5-13R-32D

Страница 1: ...Portable Air Conditioner with Heat Pump Operating Instructions Model No PH5 13R 32D 3092402 Reference No LX 130DHP...

Страница 2: ...r other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles...

Страница 3: ...max operating temperature or lower than the minimum operating tem perature the air conditioner may not work properly PACKAGE CONTENTS Portable Air Conditioner Exhaust Hoses 2 Hose Adapters 2 Window Ki...

Страница 4: ...nded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the...

Страница 5: ...PRODUCT DIAGRAM 5 Exhaust Outlet Power Cord Wrap Remote Control and Holder Drain Plug Air Intake Casters Louvers Control Panel and LED display Air Filter Compartment and Air Intake...

Страница 6: ...installed in sliding windows and sliding glass doors up to 8 ft long approximate length MOUNTING THE EXHAUST HOSE Choose a suitable location near a grounded electrical outlet and suitable window or do...

Страница 7: ...e Portable Air Conditioner above may differ from the unit described in this manual The above directions and images show general directions for Soleus Air hose portable air conditioners VENTING KIT INS...

Страница 8: ...Panel D over the Track Screw A on Hose Panel C1 5 Next take the other Hose Panel C2 and connect it to Hose Panel C1 by placing the Sliding Track Panel D over the Track Screw A on Hose Panel C2 6 The H...

Страница 9: ...OL PANEL LED CONTROL DISPLAY AUTO A C DEHUM FAN HEAT TIMER ON TIMER OFF TEMPERATURE AND TIMER INDICATOR COMPRESSOR ON OFF SLEEP MODE ON OFF BUCKET FULL 9 REMOTE RECEIVER FAN SPEED TIMER MODE TIME TEMP...

Страница 10: ...and simultaneously to change from C to F 5 TIMER To program the Auto on timer first press the TIMER button when the unit is off Once the TIMER button is pressed the hours will blink on the display Pr...

Страница 11: ...NOTE The unit operates at low fan speed during dehumidifier mode The unit cools room slightly during while dehumidifying Keep the windows and doors closed to aid the effectiveness of the unit as it re...

Страница 12: ...temperature is low and the indoor humidity is high the air conditioner may not be able to evaporate some of the moisture fast enough When this happens the water will accumulate in an emergency condens...

Страница 13: ...ER OFF LCD DISPLAY POWER BUTTON MINUTE SELECTER SLEEP BUTTON HOUR SELECTER TEMP SETTING MODE BUTTON FAN SPEED SWING LOUVER OSCILLATION OPERATING THE UNIT USING THE REMOTE CONTROL 13 Remote color may d...

Страница 14: ...an speed displayed on the remote control 4 Temperature Setting When the unit is in Air Conditioner or Heating mode you can select your desired temperature Press the or to select your desired temperatu...

Страница 15: ...ied 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly...

Страница 16: ...appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty serv...

Отзывы: