background image

Thank you for choosing a Soleus Air Portable Air Conditioner. This owner’s manual will provide you 
with valuable information necessary for the proper care and maintenance of your new product. Please 
take a few moments to thoroughly read the instructions and familiarize yourself with all the opera-
tional aspects of your new Soleus Air Portable Air Conditioner with Heat Pump technology.  
 

 

For your own records, please attach a copy of your sales receipt to this manual.  Also, write the store 
name/location, date purchased, and serial number below:

 

Store Name: ____________________________________________________ 

Location: ______________________________________________________ 

Date Purchased: _________________________________________________ 

Serial Number (located on back of unit): ______________________________

 

 2 

IMPORTANT INSTRUCTIONS 

Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this 
manual in a safe place for future reference. 

 

1)  Always place the unit on a level surface.  

2)  Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this   manual. 

3)  Maintain at least 10 inches (25 cm) clearance space around this unit.  Do not block or cover air inlet or outlet grilles. 

4)  The unit must be connected to a correctly grounded power supply. 

5)  Do not start or stop the unit by inserting or pulling out the power plug.  

6)  Do not use an adapter plug or extension cord. 

7)  Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool. 

8)  Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this manual.  

9)  Do not let children play near this unit. 

10) Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced by the 

manufacturer or a qualified service technician.  

11) When cleaning the unit, always turn the unit off and unplug the power cord. 

12) When the unit is not in use, always remove the venting kit from window. 

13)  Do Not Mix Old And New Batteries. Do Not Mix Alkaline, Standard (Carbon - Zinc), Or Rechargeable (Nickel - 

Cadmium) Batteries. 

 

Содержание PE7-10R-03

Страница 1: ...2012Soleus Air International Portable Air Conditioner with Evaporative Technology PE7 10R 03 Operating Instructions Model No PE7 10R 03 3046364...

Страница 2: ...future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inc...

Страница 3: ...at s in the Box Portable Air Conditioner Exhaust Hoses 1 Hose Adapters 1 Window Kit Adapter 1 Remote Control AAA Batteries 2 Window Kit 3 Sliding Panels 1 single hose panel 2 extension panels Owner s...

Страница 4: ...utlet D Horizontal air louvers E Casters F Power Cord Plug BACK A Hot air outlet grill B Lower air inlet grill ACCESSORIES Flexible exhaust hose with 2 adapters 3 piece set stretches from 14 1 4 to 60...

Страница 5: ...he back of the unit The exhaust hose should be kept as short and straight as possible Prevent any sharp bends in the exhaust hose as this will trap hot exhaust air The hot exhaust air can be vented th...

Страница 6: ...sidered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning prop...

Страница 7: ...ot long enough connect the extra window kit panel to fit the opening Mark and cut down a single panel of the window kit if neces sary Place the window kit between the window and the window frame as sh...

Страница 8: ...table Air Conditioner above may differ from the unit described in this manual The above directions and images show general directions for all Soleus Air single hose portable air conditioners WINDOW KI...

Страница 9: ...til it is changed by the user Press the and buttons simultaneously on the control panel to change between Celsius or Fahrenheit 5 Auto on Timer To program the Auto on timer press the TIMER button when...

Страница 10: ...running on cooling mode the exhaust hoses are required and must be vented outside using the supplied window kit Dehumidifier Mode 1 Install the exhaust hoses and window kit properly see pages 7 8 2 P...

Страница 11: ...ers of water Another option is to purchase a small hose from a hardware store that can fit around the 5 8 drain plug on the back of the unit and drain the unit into a gravity drain or larger pan for c...

Страница 12: ...he multi color display on the control panel will increase or decrease accordingly Pressing the F C button will change the temperature select between F and C 5 Swing To turn on oscillation press the SW...

Страница 13: ...the filter and dry it thoroughly out of sunlight 3 Slide the filter back into the filter compartment after it is thoroughly dried 4 If the filter is torn or unusable order a new filter by calling the...

Страница 14: ...nce parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service ALL...

Отзывы: