Specifications and Technical Data 

 

Model

 

KFHHP-22-ID / KFHHP-22-OD

 

Function Heating 

and 

Cooling 

Cooling capacity(BTU/hr) & (Watts) 

22000 / 6450 (2250-7000) 

Heating capacity(BTU/hr) & (Watts) 

24200 / 7100 (1650-8500) 

Rated voltage 

208-230V

 

Rated Frequency 

60Hz 

Cooling/Heating rated current(A) 

10.0/9.3 

Cooling/Heating rated power(W) 

3300/3200 

Cooling/Heating power input(W) 

2280/2250 

SEER 14 
EER/COP(W/W)  
HSPF 8.4 
Recycling Air Volume

m

3

/h

 

1100/1000/900 

Factory Charge 410A (lbs.)* 

R410A    5.3 lbs

 

Noise (Indoor/Outdoor) dBA 

50/59 

Maximum Vertical 

 

Height 
Differential 

Maximum Length 

 

Net Weight (Indoor/Outdoor) (lbs) 

38.6/138.9 

Dimensions (Indoor/Outdoor) 
(WxDxH)(inch) 

Indoor unit 

46.38” 

×

 8.98” 

×

12.83” 

Outdoor unit

37.40” 

×

 16.54” 

×

 33.07” 

 

Connection Pipe: 

Length (ft) 

26.25 

Gas additional charge(oz/ft) 

0.21 

Liquid Pipe (mm) 

Φ

9.52(3/8”) 

Outer Diameter 

Gas Pipe (mm) 

Φ

16(5/8”) 

Height (ft) 

32.81 

Max Distance 

Length (ft) 

65.62 

 

1.

 

All above are tested and certified to ETL specification. 

2.

 

All above could be changed without notice; the latest specifications are on the nameplate of your air 
conditioner. 

When the unit is restarded after it stopping, it can automatically resume the last running mode, and the outdoor 
unit starts later. 

 
Working temperature range 

 

 Indoor 

side 

DB/WB(°F) 

Outdoor side DB/WB(°F) 

Maximum cooling 

90 / 74 

109 / 79 

Minimum cooling 

70 / 59 

70 / -- 

Maximum heating 

81 / -- 

75 / 64 

Minimum heating 

68 / -- 

23 / 21 

 

 

 

Содержание KFHHP-22-ID

Страница 1: ...Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model KFHHP 22 ID KFHHP 22 OD Thank you for selecting Soleus Air To ensure proper operation please read this manual and keep it for future refere...

Страница 2: ...11 INSTALLATION 12 21 Installation Diagram 12 Installation Location 13 Installation 14 20 Test Operation and Check after Installation 21 ELECTRICAL SCHEMATIC DIAGRAM 22 23 Electrical Schematic Diagra...

Страница 3: ...al parts after removing filter can cause an electric shock Do not use for long periods of time if the humidity is high Condensation may be present Don t operate the air conditioner with web hands It c...

Страница 4: ...mix batteries Be sure to turn the power off when not using the air conditioner for a long time Never store flammable liquids near your air conditioner The condensing unit should be securely mounted to...

Страница 5: ...3 Description of Air Conditioner Components Air intake Air outlet On Off Switch Connecting Pipe Line set On Off Switch Signal Sensor...

Страница 6: ...e fan speed runs at Low fan speed The FAN SPEED can be memorized under various modes MODE Button When the unit is turned on press this button The AUTO COOL DRY FAN or HEAT mode can then be selected CL...

Страница 7: ...inuously press 1 sec above the tens placed on minute will be decrease 1 in every half second and it goes round with 12 hours SWING Button Press once to have louvers swing oscillate Press twice in one...

Страница 8: ...f the remote control and insert two new batteries 2 Re attach the cover Note Don t mix new and used or different types of batteries Remove batteries when the remote control is not in use for a long ti...

Страница 9: ...ion And then hold two ends of left and right louver to adjust the horizontal airflow Don t leave windows and doors open for a long time while operating the air conditioner It can decrease the air cond...

Страница 10: ...wash the panel or it could cause deformation or discoloration 3 Install surface panel Install the supports those are on two ends of surface panel into the supporting slots then cover the surface panel...

Страница 11: ...lters and other parts 2 Turn main power off 3 Clean dust from the outdoor unit Trouble Shooting Warning Don t attempt to repair the air conditioner by yourself it can cause an electric shock or fire P...

Страница 12: ...akage protection switch in operation Is TIMER ON is operation Cooling Heating efficiency is not good Is SET TEMP suitable Is air inlet or outlet obstructed Are air filters dirty Are the windows and do...

Страница 13: ...ndoor Outdoor lbs 38 6 138 9 Dimensions Indoor Outdoor WxDxH inch Indoor unit 46 38 8 98 12 83 Outdoor unit 37 40 16 54 33 07 Connection Pipe Length ft 26 25 Gas additional charge oz ft 0 21 Liquid Pi...

Страница 14: ...12 Installation Services Installation Diagram Important Notes The installation must be done by trained and qualified service personnel...

Страница 15: ...e height of the installed location should be 90 55 inch or more away from the floor 7 Install in a location where is 3 28 feet or more away from other electric appliances such as television audio devi...

Страница 16: ...well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 The extended drainage pipe in the room should be wrapped with the i...

Страница 17: ...cedures 1 Open the surface panel 2 Open the cover and cover plate of electric box Right figure 3 Remove the receiving window as shown in the below left figure 4 Wire pipe should be tightened by the fi...

Страница 18: ...ricity leakage and so on The diagram is shown as below NOTE 1 Wiring should be correctly installed 2 Tighten the nut of terminal board to avoid falling off 3 Incorrect wiring will cause the unit to ma...

Страница 19: ...nit should be connected correctly The connecting wire should be a little longer so that it can easily maintained NOTE 1 Wiring should be correctly installed 2 Tighten the nut of terminal board to avoi...

Страница 20: ...g crosses through the Connector tighten the Connector with the fix nut Install the Indoor Unit 1 When routing the piping and wiring from the left or right side of the indoor unit cut off the tailings...

Страница 21: ...of the piping flare with the valve Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to right figure Note Exceeding tightening torque will damage the flare n...

Страница 22: ...At the beginning slightly loosen joint nut of low pressure valve to check if there is air coming inside Valve of vacuum pump changes from negative to 0 Then tighten this nut 5 After finishing evacuat...

Страница 23: ...re is remote control signal main unit will run at the remote control signal c When turning it to Run position the main unit will run at received remote control order d When turning it to Stop position...

Страница 24: ...22 Electrical Schematic Diagram Electrical Schematic Diagram Indoor Unit Please Help Insert Diagram in here...

Страница 25: ...23 Electrical Schematic Diagram Outdoor Unit Please Help Insert Diagram in here...

Страница 26: ...se misuse neglect accident incorrect power line voltage fire flood or other Acts of God or normal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus maintains a cen...

Отзывы: