background image

4

Note: 

 The life of your unit may be greatly reduced if you live

in a salt air or other corrosive type environment.  Under these
conditions, the unit should be removed from its case and
completely cleaned at least once a year.  At that time any
scratches or blisters on the painted surfaces should be
sanded and repainted.  Placing an algaecide tablet in the
outdoor side of the unit’s basepan is suggested in humid
areas where algae formation is common.  

Front Grille and Filter Removal

The front contains an air filter that can be removed on left or
right side of front. To clean the filter use one of the following
methods for filter removal:

METHOD ONE

Grasp filter handle and slide filter out of unit.

1. Remove two side Phillips screws attaching case to

chassis basepan.

2. Remove two control knobs.
3. Remove two side Phillips screws attaching front 

panel 

Reinstall air filter by reversing removal procedure.

Front Grille and Cabinet Cleaning

Grille and cabinet may be cleaned with warm water and mild
soap or detergent. Cleaning and polishing compounds are not
recommended, as they may damage plastic surfaces.

Air Filter Cleaning

A dirty air filter reduces operating efficiency of unit. Filter
should be inspected at least once every week during opera-
tion. Clean filter with vacuum cleaner or wash in warm water
and mild detergent. Filter should be thoroughly dried before
replacing in unit. Do not operate unit without filter in place.

Fan Motor Care

The fan motor is permanently lubricated for long life. There is
no need to oil the motor.

Slide-out Chassis Removal from Outer Case

4. If the unit has a screw holding the basepan clip to the

chassis, remove the screw.

To reduce the risk of personal injury be 
sure to have sufficient help when moving
your unit.  A room air conditioner can
weigh between 70 and 240 pounds.

CAUTION

5. Using basepan handle, pull chassis straight out, slowly

and evenly, until approximately 9-12 inches extends

from outer case. Use both hands to grasp basepan and

pull remaining chassis from outer case.

CHASSIS

BASEPAN

CLIP

PLASTIC
FRONT

NOTE:

 Basepan clip is shipped in plastic bag with mounting

screw and condensate drain cup. Install clip after reinserting
chassis into outer case to prevent accidental chassis removal.

to case.

Содержание KC-30H

Страница 1: ...TU Room Air Conditioner with Heat Pump OPERATING AND INSTALLATION MANUAL Models KC 30H KC 35H Thank you for selecting Soleus Air To ensure proper operation please read this manual and keep it for futu...

Страница 2: ...INSTALLATION INSTRUCTIONS 12 GENERAL OPERATING INSTRUCTIONS 13 OPERATING CONTROLS 14 BEFORE CALLING SERVICE 15 WHEN SERVICE IS REQUIRED 15 ANY QUESTIONS 15 THROUGH THE WALL INSTALLATION INSTRUCTIONS...

Страница 3: ...an take from 1 to 3 hours depending on installer s knowledge and skill 3 If you encounter problems during installation call our Technical Support and Warranty Service at 1 888 8 SOLEUS If your problem...

Страница 4: ...e this device for unattended cooling of persons or animals unable to react to product failure Failure of unattended air conditioner may result in extreme heat in area intended for cooling causing heat...

Страница 5: ...manual or in the mounting kit assembly Follow these instructions carefully Keep these instructions with this manual for future reference Your unit will be one of the following three designs Unit with...

Страница 6: ...eaningandpolishingcompoundsarenot recommended as they may damage plastic surfaces Air Filter Cleaning A dirty air filter reduces operating efficiency of unit Filter should be inspected at least once e...

Страница 7: ...Do not use an extension cord Free movement of air in room to be cooled A large enough opening for the air conditioner Adequate wall support for weight of air conditioner Air conditioner weighs betwee...

Страница 8: ...rements are listed in the chart below Follow the requirements for the type of plug on the power supply cord A 27 min 68 6 cm B 16 min 41 3 cm A 16 40 6 cm B 22 57 5 cm C Wood thickness A B B C C A Pow...

Страница 9: ...se leakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a...

Страница 10: ...gently Be sure your air conditioner cabinet does not fall out of the opening during installation or removal The location where the power cord exits the air conditioner should be no more than 4 ft 122...

Страница 11: ...Attach foam adhesive seal along the bottom of the curtain bottom channel Install Cabinet into Window Handle air conditioner gently Be sure your air conditioner cabinet does not fall out of the opening...

Страница 12: ...p of lower window and against upper window sash 3 Use a drill bit to drill a starter hole through the hole in the bracket and into the window sash 4 Attach window lock bracket to window sash with 10 x...

Страница 13: ...all opening Square and level frame 6 Attach frame securely to the wall Install Cabinet into Wood Frame 1 Insert cabinet into the framed wall opening The top of the cabinet should extend 13 mm into the...

Страница 14: ...ol knobs on some models NOTE For through the wall installations if needed install molding around room side of cabinet 7 Plug into a grounded 3 prong outlet 8 Press RESET on the power supply cord plug...

Страница 15: ...om the indoor air However in very humid conditions excess amounts of water may drip off the unit chassis If this proves to be a problem install the condensate drain cup included with the unit to route...

Страница 16: ...lters and circulates room air with the fan running continuously on high speed Also heats while the compressor or electric heater is running Select this setting for maximum air circulation and heating...

Страница 17: ...for low outdoor temperatures Clean air filter by vacuuming or washing with water and mild soap Turning Temperature Control to warmer setting reduces occurrence and duration of frost FROST ON OUTDOOR...

Страница 18: ...tructions All GREE brand Compact RoomAir Conditioners feature a slide out chassis Chassis and front cover must be re moved from outer case for installation In order to reinstall the chassis and re att...

Страница 19: ...g Place outer case in opening flush against one side of opening Use carpenter s level and ensure case is level from side to side and has a 3 8 inch slope from front to back back of case must be 3 8 in...

Страница 20: ...ust be made in wall opening to ensure free air flow to the side louvers This can be accomplished by chamfering the vertical portions of the outside opening as shown Ventilation louvers on top of case...

Страница 21: ...ling AMPS 4 8 4 6 5 9 5 5 Cooling Watts 970 990 1210 1235 Cooling EER 9 8 9 4 Heating AMPS 4 5 4 2 5 8 5 1 Heating Watts 850 870 1100 1140 Heating EER 9 8 9 2 Electric Heat AMPS 15 6 16 15 6 16 Electr...

Страница 22: ...e neglect accident incorrect power line voltage fire flood or other Acts of God or normal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus maintains a centralized...

Отзывы: