background image

 $ 

 

 

CONTROL PANEL BUTTONS 

 

1) 

Power On and Off 

- Press the 

POWER 

button once to manually turn the unit on. Press the 

POWER 

but-

ton once more to turn the unit off.  

CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS 

 

TIMER

SPEED

MODE

POWER

TEMPERATURE

COOL

BUCKET FULL

FAN

DRY

HIGH

MEDIUM

LOW

Bucket Full 

Indicator 

Mode Selection 

Button  

Increase  

Temperature/Timer 

Button 

Signal Receiver 

POWER  
ON/OFF 

Button 

Fan Speed 

Button 

Air Conditioner 

Mode 

Indicator 

Dehumidifier 

Mode  

Indicator 

Fan Speed  

Indicators 

Fan 

Mode 

Indicator 

Timer 

Button 

Decrease  

Temperature/Timer 

Button 

88

72

OPERATING INSTRUCTIONS 

CONTROL PANEL 

3) 

Temperature 

- Select the desired temperature by pressing either ▲ or

 

▼ key when using the unit in     

Air Conditioner mode. The temperature indicator flashes to display the desired temperature setting. Af-
ter the desired temperature is set, the temperature indicator will flash 10 seconds before it returns to 
current room temperature. The temperature indicator display shows temperature in Fahrenheit.  

 

- This unit has '-way directional louvers. Use the louver guides manually to direct 

air up and down. 

 

2) 

Mode Selection 

- Press the 

MODE

 Button repeatedly to cycle between the different modes: Air 

Conditioner mode, Dehumidifier (Dry) mode, and Fan only mode. Each press of the MODE button will 
light up a different icon on the control panel. The exhaust hose and window kit must be installed when 
the unit is in Air Conditioner, and Dehumidifier mode. When using the unit as a fan, it is not necessary 
to keep the exhaust hose and window kit connected to the unit. 

4) 

Bucket Full 

- When the unit cannot evaporate the collected moisture fast enough, the excess water will 

collect in a backup water tank located inside the unit. Once the tank is full, Bucket Full indicator will light 
up. 

5) 

Louver Direction

6) 

TIMER - 

Press the 

TIMER 

button to turn the unit auto-on or auto-off. Set the timer by pressing either ▲ 

or▼ button. 

Содержание iCongo PSQ-08-01

Страница 1: ...V16 Model No PSQ 08 01 PSQ 10 01 PSQ 12 01 8 000 10 000 12 000 BTU Portable Air Conditioner Operating Instructions ...

Страница 2: ...fe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded power supply 5 Do not start or stop the un...

Страница 3: ...e air conditioner may not work properly MODEL NUMBER PSQ 08 01 PSQ 12 01 PSQ 10 01 COOLING CAPACITY 8 000 BTU Hr 12 000 BTU Hr 1 000 BTU Hr DEHUMIDIFYING CAPACITY 86 pts Day 6 pts Day 6 pts Day COOLING POWER USAGE 1030 Watts 8 9 Amps 1 50 Watts 1 Amps 1250 Watts 11 2 Amps AIR FLOW VOLUME 206 CFM 206 CFM 206 CFM POWER SOURCE 115 V 60 HZ 115 V 60 HZ 115 V 60 HZ NOISE LEVEL 58 dB A 58 dB A 58 dB A PR...

Страница 4: ...cord shields are not grounded must be considered a shock hazards if exposed The cord shield must not be connected to ground any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet 2 Press TEST Button circuit should trip cutting power to the air conditioner 3 Press RESET button If test button is p...

Страница 5: ...utlet Cover 4 Air Exhaust Cover 5 Hot Air Exhaust Opening 6 Cold Air Filter 7 Continuous Drain Port 8 Cold Air Intake 9 Hot Air Filter 10 Hot Air Intake 11 Condensation Drain Hole 12 Casters 13 Exhaust Hose 14 Screw 15 Window Kit 16 Remote Control 17 AAA Batteries 18 Window Kit Adapter 19 Continuous Drain Rubber Plug 20 Condensation Drain Rubber Plug 5 ...

Страница 6: ...ut of the room to complete the air exchange When the unit is operating in fan mode no outdoor air exchange takes place The window kit and exhaust hose do not need to be installed when the unit is used as a fan NOTE The supplied window kit can be installed in sliding windows and sliding glass doors up to 4 ft long approximate length Screw Panel A Panel B Exhaust Hose Window Kit Adapter ...

Страница 7: ...imize efficiency Note The unit above may differ from the unit described in the manual the above directions and images show general directions for Soleus Air single hose Portable Air Conditioner Connect the Exhaust Hose over the hot air exhaust opening Exhaust Hose This side up Window Kit Adapter Exhaust Host Window Kit Attach the Exhaust Hose to the Window Kit Adapter attach the Window Kit Adpater...

Страница 8: ...s free from gaps and or air pockets when taking measurements 3 Lock the screw into the holes that correspond with the width that your window requires to ensure that there are no gaps or air pockets in the window kit assembly after installation 1 Parts Panel A with exhaust hose opening Panel B Screw to lock window kit in place Panel A Screw Panel with Exhaust Opening Panel B A B ...

Страница 9: ...ture indicator will flash 10 seconds before it returns to current room temperature The temperature indicator display shows temperature in Fahrenheit This unit has way directional louvers Use the louver guides manually to direct air up and down 2 Mode Selection Press the MODE Button repeatedly to cycle between the different modes Air Conditioner mode Dehumidifier Dry mode and Fan only mode Each pre...

Страница 10: ...uired and must be vented outside using the supplied window kit Dehumidifier Mode 1 Install the exhaust hose and window kit properly see pages 7 8 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER Button 4 Press the MODE button until the dehumidifier mode indicator lights up on the control panel display NOTE The unit operates at low fan speed during dehumidifi...

Страница 11: ...OL TIMER BUTTON MODE BUTTON POWER BUTTON FAN SPEED BUTTON TIMER TEMP DECREASE TIMER TEMP INCREASE HOUR BUTTON MINUTE BUTTON This Button does not have a function SET TEMPERATURE MODE DISPLAY FAN SPEED INDICATOR TIME TIMER ON OFF INDICATOR TIMER TIME LOCK UNLOCK INDICATOR MIN HOUR TIMER FAN SPEED MODE HOLD ...

Страница 12: ...ote control LCD display Press the HOUR button to set the timer The timer can be set in intervals of 1 hour up to 12 hours 6 Hold Button Press this button to lock and unlock the remote control 1 Remove cover on back of the remote control to expose CLK button 2 Use a paper clip or pen to press CLK button present time on LCD display will start to flash 3 Press HOUR or MIN button to adjust time 4 Pres...

Страница 13: ...able AC on a level surface 2 Remove the plug on continuous drain port on the side of the unit to access the Garden Hose Drain Port 3 Thread a garden hose not supplied onto the accessible Garden Hose Drain Port 4 Lead Garden hose to a floor drain and cut to length 5 Make sure that there are no kinks or knots in the garden hose See Picture Below 6 Turn on the unit and gravity draining will begin aut...

Страница 14: ...le on the bottom side of the unit Lead the hose to a floor drain or larger pan for continuous drain age It is not advised to use continuous drainage when the room temperature is higher than 90 F HOW TO DRAIN THE INTERNAL WATER TANK You will need a small pan approximately 1 high to catch the water coming out of the water tank Once the water tank is empty the unit will resume operation within a few ...

Страница 15: ...ghly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any exces...

Страница 16: ...st hose correctly keeping it as short and free of curves as possible Check and remove anything obstructing air discharge During operation there is an unpleasant smell in the room Air filter is dirty Remove air filters clean and re install Air conditioner does not oper ate after restarting the unit The internal compressor safety de vice prevents the unit from being restarted until three minutes hav...

Страница 17: ... system to identify a number of malfunctions Error messages are displayed on the control panel display Error Codes Possible Causes Error Messages E2 Temperature Sensor Failure Self Diagnosis E3 Internal Pipe Sensor Failure Self Diagnosis Turn Off the Unit E4 CPU Failure System Shut Down ...

Страница 18: ... of the case or other appearance parts caused by wear x Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Home Comfort x Freight and Insurance cost for the warranty service x Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS HOME COMFORT ...