background image

 1' 

 

REMOTE CONTROL OPERATING INSTRUCTIONS  
 

3) 

Fan Speed 

- Press the 

FAN 

speed button to cycle through high, medium, low fan speeds. When the 

unit is in Air Conditioner mode, the fan speeds will cycle through in this order: High, Medium, Low, 
When the unit is in Fan mode, the fan speeds will cycle through in this order: High, Medium, Low.  

4) 

Temperature Setting 

- When the unit is in Air Conditioner mode you can select your desired tem-

perature. Press the ▲ or ▼ to select your desired temperature setting. The temperature on the LCD dis-
play on the remote control will increase or decrease accordingly.  

5) 

TIMER 

   

 

 

 

 

 

 

 

 

 

 

         

Auto-On: 

To program the timer, when the unit is off, point the remote at the unit and press the 

TIMER 

button. Once 

TIMER 

is pressed, the timer 

ON

 indicator will display on the remote control LCD dis-

play. Press the 

HOUR 

button to set the timer. The timer can be set in intervals of 1 hour up to 12 hours. 

                                                                                   

Auto-Off: 

While the unit is operating, point the remote at the unit and press the 

TIMER 

button. Once 

the 

TIMER

 is pressed, the timer 

OFF 

indicator will display on the remote control LCD display. Press 

the 

HOUR 

button to set the timer. The timer can be set in intervals of 1 hour up to 12 hours. 

6) 

Hold Button

 

- Press this button to lock and unlock the remote control. 

 

 

 

                                                             

           
 
 

1. 

Remove cover on back of the remote control to expose 

CLK 

button.

 

2. Use a paper clip or pen to press 

CLK 

button; present time on LCD display will start to flash. 

3

. Press 

HOUR 

or 

MIN 

button to adjust time.

 

4. Press 

CLK 

button again to complete set up. 

Time Adjustment

 

Reset Remote Control

 

Use a paper clip or pen to press the 

RST 

button once to 

reset the remote control. 

CLK

RST

     Time 
Set Button

Remote Control 
Reset Button

CLK

RST

2) 

Mode Selection 

- Press the 

MODE

 Button repeatedly to cycle between the different modes: Air 

Conditioner, Dehumidifier, Fan-Only mode. The selected mode will light up on remote con-
trol LCD display to indicate which mode the unit is currently operating in.  

1) 

Power On and Off 

- If the unit is already on, press the 

ON/OFF 

button on the remote while pointing 

the remote away from the unit. This will turn the remote on. If the unit is off, now press the 

ON/OFF 

button once to turn the unit on. Press the 

ON/OFF 

button once more to turn the unit off. When in Air 

Conditioner mode, the selected temperature will appear on the remote control LCD display.  

Содержание iCongo PSQ-08-01

Страница 1: ...V16 Model No PSQ 08 01 PSQ 10 01 PSQ 12 01 8 000 10 000 12 000 BTU Portable Air Conditioner Operating Instructions ...

Страница 2: ...fe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded power supply 5 Do not start or stop the un...

Страница 3: ...e air conditioner may not work properly MODEL NUMBER PSQ 08 01 PSQ 12 01 PSQ 10 01 COOLING CAPACITY 8 000 BTU Hr 12 000 BTU Hr 1 000 BTU Hr DEHUMIDIFYING CAPACITY 86 pts Day 6 pts Day 6 pts Day COOLING POWER USAGE 1030 Watts 8 9 Amps 1 50 Watts 1 Amps 1250 Watts 11 2 Amps AIR FLOW VOLUME 206 CFM 206 CFM 206 CFM POWER SOURCE 115 V 60 HZ 115 V 60 HZ 115 V 60 HZ NOISE LEVEL 58 dB A 58 dB A 58 dB A PR...

Страница 4: ...cord shields are not grounded must be considered a shock hazards if exposed The cord shield must not be connected to ground any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet 2 Press TEST Button circuit should trip cutting power to the air conditioner 3 Press RESET button If test button is p...

Страница 5: ...utlet Cover 4 Air Exhaust Cover 5 Hot Air Exhaust Opening 6 Cold Air Filter 7 Continuous Drain Port 8 Cold Air Intake 9 Hot Air Filter 10 Hot Air Intake 11 Condensation Drain Hole 12 Casters 13 Exhaust Hose 14 Screw 15 Window Kit 16 Remote Control 17 AAA Batteries 18 Window Kit Adapter 19 Continuous Drain Rubber Plug 20 Condensation Drain Rubber Plug 5 ...

Страница 6: ...ut of the room to complete the air exchange When the unit is operating in fan mode no outdoor air exchange takes place The window kit and exhaust hose do not need to be installed when the unit is used as a fan NOTE The supplied window kit can be installed in sliding windows and sliding glass doors up to 4 ft long approximate length Screw Panel A Panel B Exhaust Hose Window Kit Adapter ...

Страница 7: ...imize efficiency Note The unit above may differ from the unit described in the manual the above directions and images show general directions for Soleus Air single hose Portable Air Conditioner Connect the Exhaust Hose over the hot air exhaust opening Exhaust Hose This side up Window Kit Adapter Exhaust Host Window Kit Attach the Exhaust Hose to the Window Kit Adapter attach the Window Kit Adpater...

Страница 8: ...s free from gaps and or air pockets when taking measurements 3 Lock the screw into the holes that correspond with the width that your window requires to ensure that there are no gaps or air pockets in the window kit assembly after installation 1 Parts Panel A with exhaust hose opening Panel B Screw to lock window kit in place Panel A Screw Panel with Exhaust Opening Panel B A B ...

Страница 9: ...ture indicator will flash 10 seconds before it returns to current room temperature The temperature indicator display shows temperature in Fahrenheit This unit has way directional louvers Use the louver guides manually to direct air up and down 2 Mode Selection Press the MODE Button repeatedly to cycle between the different modes Air Conditioner mode Dehumidifier Dry mode and Fan only mode Each pre...

Страница 10: ...uired and must be vented outside using the supplied window kit Dehumidifier Mode 1 Install the exhaust hose and window kit properly see pages 7 8 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER Button 4 Press the MODE button until the dehumidifier mode indicator lights up on the control panel display NOTE The unit operates at low fan speed during dehumidifi...

Страница 11: ...OL TIMER BUTTON MODE BUTTON POWER BUTTON FAN SPEED BUTTON TIMER TEMP DECREASE TIMER TEMP INCREASE HOUR BUTTON MINUTE BUTTON This Button does not have a function SET TEMPERATURE MODE DISPLAY FAN SPEED INDICATOR TIME TIMER ON OFF INDICATOR TIMER TIME LOCK UNLOCK INDICATOR MIN HOUR TIMER FAN SPEED MODE HOLD ...

Страница 12: ...ote control LCD display Press the HOUR button to set the timer The timer can be set in intervals of 1 hour up to 12 hours 6 Hold Button Press this button to lock and unlock the remote control 1 Remove cover on back of the remote control to expose CLK button 2 Use a paper clip or pen to press CLK button present time on LCD display will start to flash 3 Press HOUR or MIN button to adjust time 4 Pres...

Страница 13: ...able AC on a level surface 2 Remove the plug on continuous drain port on the side of the unit to access the Garden Hose Drain Port 3 Thread a garden hose not supplied onto the accessible Garden Hose Drain Port 4 Lead Garden hose to a floor drain and cut to length 5 Make sure that there are no kinks or knots in the garden hose See Picture Below 6 Turn on the unit and gravity draining will begin aut...

Страница 14: ...le on the bottom side of the unit Lead the hose to a floor drain or larger pan for continuous drain age It is not advised to use continuous drainage when the room temperature is higher than 90 F HOW TO DRAIN THE INTERNAL WATER TANK You will need a small pan approximately 1 high to catch the water coming out of the water tank Once the water tank is empty the unit will resume operation within a few ...

Страница 15: ...ghly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any exces...

Страница 16: ...st hose correctly keeping it as short and free of curves as possible Check and remove anything obstructing air discharge During operation there is an unpleasant smell in the room Air filter is dirty Remove air filters clean and re install Air conditioner does not oper ate after restarting the unit The internal compressor safety de vice prevents the unit from being restarted until three minutes hav...

Страница 17: ... system to identify a number of malfunctions Error messages are displayed on the control panel display Error Codes Possible Causes Error Messages E2 Temperature Sensor Failure Self Diagnosis E3 Internal Pipe Sensor Failure Self Diagnosis Turn Off the Unit E4 CPU Failure System Shut Down ...

Страница 18: ... of the case or other appearance parts caused by wear x Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Home Comfort x Freight and Insurance cost for the warranty service x Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS HOME COMFORT ...