Soleus Air HGW-308 Скачать руководство пользователя страница 7

ASSEMBLY - INSTALLATION 

 7 

Required Tools for Floor Use:

 

Phillips screwdriver (not supplied) 

 

 

Estimated Assembly Time for Floor Use:  
1 minute

 

 

 

Assembly Instructions for Floor Use:

 

Insert the feet and bolts onto the unit as shown in the 
diagram. 

 

 

 

Required Tools for Wall Mounting: 

Phillips screwdriver (not supplied) 
Drill (not supplied) 
Hammer (not supplied) 

 

 

Estimated Mounting Time: 5 minutes

 

 

 

Mounting Instructions:

 

STEP 1 
Using the mounting support as a guide, mark the first screw 
hole on the wall using the tip of a long nail. 

  

STEP 2 
Move the mounting support, and drill the first screw hole. 

  

STEP 3 
Insert the first mounting anchor into the drilled hole. 

  

STEP 4 
Place the mounting support on the wall. Insert a screw through 
the mounting support and anchor. Tighten the screw lightly. 

  

STEP 5 
Use the other side of the mounting support to mark the second 
screw hole on the wall [approximately 5 7/16 in.]. 

  

STEP 6 
Move the mounting support, and drill the second hole. 

  

STEP 7 
Insert the second mounting anchor into the drilled hole. 

  

STEP 8 
Place the mounting support on the wall. Insert the second screw 
through the mounting support and anchor. Firmly tighten both 
screws. 

  

STEP 9 
After mounting the heater, insert two screws into the bottom 
holes and secure the heater to the wall for safety purposes. 

 

 
 

 

 

 

 

Содержание HGW-308

Страница 1: ...2009 Soleus Air International HGW 308 Wall Mountable Micathermic Heater Model No HGW 308 3092402...

Страница 2: ...er 4 Keep combustible materials such as furniture pillows bedding paper clothes and curtains at least 3 ft from the front of the heater and keep them away from the sides and rear DO NOT place towels o...

Страница 3: ...00W 14 To avoid fire or shock hazard plug the unit directly into a 120 V AC electrical outlet 15 To disconnect heater turn controls to OFF then remove plug from outlet Pull firmly on the plug DO NOT u...

Страница 4: ...l automatically shut off To reset the heater unplug the heater power cord from the electrical outlet for 10 minutes After 10 minutes plug the heater into the electrical outlet and turn on using the su...

Страница 5: ...rature Control Knob 3 Temperature Control Red Light Indicator 4 Power Supply Cord 5 Foot with Caster 6 Metal Grille 7 Built in Handle 8 Mounting Hole 9 Mounting Support 10 Screws 11 Mounting Anchor fo...

Страница 6: ...picted in the drawings Remove the Styrofoam from both ends of the heater and remove the plastic bag Remove the remaining bag from the box One bag contains feet with casters Fig 1 Save the packaging fo...

Страница 7: ...g support and drill the first screw hole STEP 3 Insert the first mounting anchor into the drilled hole STEP 4 Place the mounting support on the wall Insert a screw through the mounting support and anc...

Страница 8: ...ndicator turns on Fig 2 The Tem perature Control should begin Note The Red Light Indicator will turn off when the room reaches the desired tempera ture After a while as the room temperature falls the...

Страница 9: ...to the area that needs it most 3 To save energy and in turn save money in the winter place the heater in a room or area that needs extra heat instead of raising the thermostat on your central heating...

Страница 10: ...e or deterioration to the surface of the heater 4 DO NOT immerse the heater in water 5 Wait until the unit is completely dry before use STORAGE Store the heater in a cool dry location when not in use...

Страница 11: ...s caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service ALL WARRANTI...