background image

 4 

 

LCDI POWER CORD AND PLUG

 

 

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord 
and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexi-
ble cord with no termination on the load side and a LCDI attachment plug on the line side. 
 
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the 
nominal     current leakage between the cord shield and either load conductor exceeds a predetermined 
value. The cord will remain de-energized until the devise has been manually reset. This is intended to re-
duce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded 
and they must be considered a shock hazards if  exposed. The cord shield must not be connected to ground 
or to any exposed metal. 
 
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:  
 

1. Plug power cord into wall outlet

. The LED light will turn on.

 

2. Press TEST Button, circuit should trip, cutting power to the air conditioner

. When this occurs,

  
3. Press RESET button 

to restore power to the machine. Once power is restored, the LED light 

    will turn on again. 

 

If test button is pressed and unit  can still be turned on, current leakage has been detected. Do not use the 
air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting 
recommendations.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

WARNING: 
 

1. 

DO NOT press the TEST button while the air conditioner is operating. 

2. 

The TEST and RESET buttons should not be used as 

ON

” 

and 

OFF

” 

switches. 

3. 

The cord and plug are not intended to offer protection to externally connected loads or supply circuits. 

4. 

The cord and plug are intended for indoor use only. 

LED LIGHT

 

 

the LED light will turn off.

Note: Your units power cord and plug may differ from the one shown.

Содержание HCB-P11-A

Страница 1: ...BTU Portable Air Conditioner Evaporative Technology Operating Instructions Model No HCB P11 A 3092402 Reference No BPA11 V 140204...

Страница 2: ...nce 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clea...

Страница 3: ...is higher than the max operating temperature or lower than the minimum operating tem perature the air conditioner may not work properly PACKAGE CONTENTS Portable Air Conditioner 1 Exhaust Hose 1 Hose...

Страница 4: ...nd or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Pre...

Страница 5: ...M Casters Louvers Control Panel and LED display Air Filter Compartment and Air Intake 5 Air Filter Compartment and Air Intake Power Cord Wrap Remote Control Holder Exhaust Outlet Drain Plug Carry Hand...

Страница 6: ...able location near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both ends of the exhaust hose approximately 6 inches Screw the window kit adap...

Страница 7: ...e opening Figure D If necessary mark the kit and cut one end down to properly fit the opening Figure E F 5 Attach the window kit adapter to the window kit Figure G 6 Place the window kit back into the...

Страница 8: ...ews A Do not tighten the Wing Nuts B all the way make sure they are somewhat loose 4 Now place the Sliding Track Panel D over the Track Screw A on Hose Panel C1 5 Next take the other Hose Panel C2 and...

Страница 9: ...d by the user The temperature indicator display shows temperature in Celsius or Fahrenheit Press the and simultaneously to change between Celsius and Fahrenheit 5 Auto on Timer To program the Auto on...

Страница 10: ...exhaust hose is required and must be vented outside using the supplied window kit Dehumidifier Mode 1 Install the exhaust hose and window kit properly see pages 7 8 2 Plug the Power Cord into an elec...

Страница 11: ...nit and drain the unit into a gravity drain or larger pan for continuous drainage It is not advised to use continuous drain age when the room temperature is higher than 90 F If you do not need the eme...

Страница 12: ...nel shows temperature in Celsius or Fahren heit Press the C F button to change the temperature select between Celsius and Fahrenheit 5 Auto on Timer To program the Auto on timer press the TIMER button...

Страница 13: ...ied 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly...

Страница 14: ...rance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Home Comfort Freight and Insurance cost for the warranty service ALL WARR...

Отзывы: