background image

14 

 

 

REMOTE CONTROL OPERATING INSTRUCTIONS

 

 

1)   

Power On and Off 

If the unit is already on, press the 

POWER 

  

button on the remote while pointing 

the remote away from the unit. This will turn the remote on. If the unit is off, now press the 

POWER 

button 

once to manually turn the unit on. Press the 

POWER 

button once more to turn the unit off. When in Air 

Conditioner mode, the selected temperature will appear on the remote-control LCD display. When the unit is in 
Fan mode, Dehumidifier mode and Auto mode, no temperature will be displayed. This shows that temperature 
selection is not available when the unit is in Fan mode, Dehumidifier mode, and Auto mode. 

 

2)   

Mode Selection 

Press the 

MODE 

Button repeatedly to cycle between the different modes: Air 

Conditioner, Dehumidifier, Fan, Heat and Auto. The left side of the remote-control LCD display will light up 
showing which mode is selected. An arrow ◄ will display next to the mode that is selected, indicating which 
mode the unit is currently operating in. 

 

3)   

Fan Speed 

Press the 

FAN 

speed button to cycle through high, medium, low, and auto fan speeds. 

The display on the remote control will show an arrow ► by the current fan speed on the remote-control LCD 
display. When the unit is in Air Conditioner mode, Heat mode and Auto mode, the fan speeds will cycle through 
in this order: High, Medium, Low, Auto. When the unit is in Dehumidifier mode, the fan 
speeds will only in auto fan speed. When the unit is in Fan mode, the fan speeds will cycle through in this 
order: High, Medium, Low. Each change in speed will be associated with a “beep” sound from the unit. 

 

4)   

Temperature Setting 

When the unit is in Air Conditioner mode or Heat mode, you can select your desired 

temperature. Press the ▲ or ▼ to select your desired temperature setting. The temperature on the LCD display 
on the remote control will increase or decrease accordingly. Pressing the 

°C 

/

°F 

button will change the 

temperature select between °C and °F. 

 

5)   

SLEEP MODE -

 

To set Sleep mode, make sure the unit is in Air Conditioner mode, Heat mode, 

Dehumidifier mode or Auto mode. Press the 

SLEEP 

Button on the remote control, the remote control will 

show an arrow ▲ under the “SLEEP” icon on the remote-control LCD display. When in 

SLEEP 

mode, the fan 

will run on low to keep fan noise at minimum. The temperature setting will gradually increase to 1°F above the 
original set temperature for each of first 2 hours. The unit will keep operating the same temperature for 6 hours 
and switch to standby mode.

 

 

6)   

TIMER 

Auto-On: 

To program the timer, when the unit is off, point the remote at the unit and press the 

TIMER 

button. 

Once 

TIMER 

is pressed, the arrow ▼ will display above the TIMER ON icon on the remote-control LCD 

display as standby mode. Press the arrow buttons ▲ or ▼ to set the timer. The timer can 

be set in intervals of 0.5 hours up to 10 hours, then in intervals of 1 hour up to 24 hours. Once the desired time 
is selected, press the 

TIMER 

button once more to set it. The arrow ▼ will display above the TIMER ON icon 

on the remote-control LCD display to indicate that the timer has been set. 

Auto-Off: 

While the unit is operating, point the remote at the unit and press the 

TIMER 

button. Once the 

TIMER 

is pressed, the arrow ▼ will display above the TIMER OFF icon on the remote-control LCD display. 

Press the arrow buttons ▲ or ▼ to set the timer. The timer can be set in intervals of 0.5 hours up to 10 hours, 
then in intervals of 1 hour up to 24 hours. Once the desired time is selected, press the 

TIMER 

button once more 

to set it. The arrow ▼ will display above the TIMER OFF icon on the remote-control LCD display to indicate 
that the timer has been set. 

 

7)   

SWING 

To turn on oscillation, press the 

SWING 

button on the remote control when the unit is in air 

conditioner mode, heat mode, fan mode, and dehumidifier mode. The remote control will show an arrow ► by 
to the “SWING” icon on the remote-control LCD display. Once you press 

SWING, 

the louvers on the unit will 

oscillate up and down.

 

 

 

 

 

 

 

Содержание FEA-12HP

Страница 1: ...12 000 BTU Portable Air Conditioner with Heat Pump Operating Instructions V190102 ...

Страница 2: ...gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded power supply 5 Do not start or stop the unit by inserting or pulling out the power plug 6 Do not use an adapter plug or extension cord 7...

Страница 3: ... environment temperature is higher than the max operating temperature or lower than the minimum operating temperature the air conditioner may not work properly Model Number FEA 12HP Cooling Capacity 12 000 BTU Heating Capacity 10 000 BTU Dehumidifier Capacity 132 Pints Day Cooling Power Usage 1250 Watts 10 6 Amps Heating Power Usage 1150 Watts 10 3 Amps Air Flow Volume H M L 206 196 165 CFM Power ...

Страница 4: ...e considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet 2 Press TEST Button circuit should trip cutting power to the air conditioner 3 Press RESET button for use If test button is pressed and unit can st...

Страница 5: ... to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Press TEST Button circuit should trip cutting power to the air conditioner When this occurs the LED light will turn off 3 Press RESET button to restore power to the machine Once power is restored...

Страница 6: ...6 PRODUCT DIAGRAM ...

Страница 7: ... 4 6 ft long approximate length MOUNTING THE EXHAUST HOSE Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both ends of the exhaust hose approximately 6 inches Screw the window kit adapter onto one end of the exhaust hose counter clockwise Screw the exhaust hose connector onto the other end of the exhaust hose co...

Страница 8: ... the Window Kit Adapter Attach the Optional Window Kit Adapter Extension to the Window Kit Adapter Close the window tightly Your Portable Air Conditioner is good to go 3 Open the window or door to adjust the length of the Window Kit to fit the opening If necessary mark the kit and cut one end down to properly fit the opening Note When using the venting system keep the Exhaust Hose as straight as p...

Страница 9: ...ide Panel B and C into Panel A and size to window width Windows sizes vary When sizing the window width be sure that the window kit assembly is free from gaps and or air pockets when taking measurements 3 Insert the screw into the holes that correspond with the width that your window requires to ensure that there are no gaps or air pockets in the window kit assembly after installation ...

Страница 10: ...sing the unit in Air Conditioner mode The temperature indicator flashes to display the desired temperature setting After the temperature is set the unit will display this temperature setting until it is changed by the user The temperature indicator display shows temperature in Fahrenheit Under stand by condition press and hold the and key to switch between Celsius and Fahrenheit 4 Timer Press the ...

Страница 11: ...CONTROL OPERATING THE UNIT USING THE REMOTE CONTROL REMOTE CONTROL LCD DISPLAY POWER BUTTON MODE BUTTON TIMER TEMP INCREASE TIMER TEMP DECREASE TIMER BUTTON FAN SPEED SLEEP BUTTON C F BUTTON SWING BUTTON THIS BUTTON DOES NOT HAVE A FUNCTION ...

Страница 12: ...C F button will change the temperature select between C and F 5 SLEEP MODE To set Sleep mode make sure the unit is in Air Conditioner mode Heat mode Dehumidifier mode or Auto mode Press the SLEEP Button on the remote control the remote control will show an arrow under the SLEEP icon on the remote control LCD display When in SLEEP mode the fan will run on low to keep fan noise at minimum The temper...

Страница 13: ...ide using the supplied window kit Dehumidifier Mode 1 Install the exhaust hose and window kit properly see pages 7 8 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER Button 4 Press the MODE button until the dehumidifier mode indicator lights up on the control panel display NOTE The unit operates at auto fan speed during dehumidifier mode The unit cools room ...

Страница 14: ...R button 4 Press the MODE button until the control panel display as below NOTE Auto Mode will operate the unit in Air Conditioning Mode when the temperature is above 73 degrees Fan Mode when the temperature is between 68 degrees to 73 degree and Heating Mode when the temperature is below 68 degrees HOW TO INSTALL CONTINUOUS DRAIN OPTION 1 Place the Portable AC on a level surface 2 Remove the cap o...

Страница 15: ...The unit along with the fan will automatically shut off when the unit displays Full Tank To resume operation quickly empty the water container according to the following steps 1 Do not move the unit when the water container is full 2 Place the drain pan under the drainage port at the back of the unit 3 Remove the rubber plug from the drain hole The condensate water will drain out automatically 4 W...

Страница 16: ...ghly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any exces...

Страница 17: ...haust hose correctly keeping it as short and free of curves as possible Check and remove anything obstructing air discharge During operation there is an unpleasant smell in the room Air filter is dirty Remove air filters clean and re install Air conditioner does not operate after restarting the unit The internal compressor safety de vice prevents the unit from being restarted until three minutes h...

Страница 18: ...rost prevention PROBE FAILURE Sensor damaged FULL TANK Safety tank full WHAT SHOULD I DO The appliance is fitted with a frost protection device to avoid excessive formation of ice The unit will start up automatically when the defrosting process is completed If this is displayed please contact the customer support center Empty the internal safety tank See the CONDENSATION EVAPORATION section on Pag...

Страница 19: ... the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by SoleusAir West Freight and Insurance cost for the warranty service Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUSAIR WEST DISCL...

Отзывы: