Sonde
de
débit
+ S - C P 1 2 3 4 5 6
7 8 9 1 0 11 12 C
Power
Outputs
Flowmeter
Master valve
SMART-IS 1 - 6
SMART-IS 9 - 12
Plug the -
S +
input to a water meter equipped with a flow sensor, as described
below. Use flow sensors in dry contact or equivalent.
For polarized flow sensors respect the polarisation :
Red cable > + / Black cable > -
LED STATUS INFORMATIONS
Green LED:
standard functioning
Green LED blinking:
one station is working (the number of blinking corresponds to
the activate station’s number)
Orange LED blinking:
ongoing firmware actualization
Orange LED 4 flashes:
short-circuit on one station
Fixed red LED:
the product is in initialization mode during 2 minutes
Fast blinking red LED:
Default (sensor opened or flow threshold reached).
Suspended watering but the program goes on. If «
Default
» disappears, the program
starts again (the LED’s flashes number corresponds to the actual inactive station).
Red LED blinking twice:
the controller is no more time-syncronized, connect again
to re-synchronize it.
Red LED blinking 3 times:
Wi-Fi signal lost (wrong Wi-Fi key or the
SMART-IS
installation is too far or the internet connection has been lost)