INSTALLATION GUIDE
KM SERIES MICROWAVE LINK
52
Rev 1.1
2.
Re-install the 4 (6-32) socket-head screws removed earlier to secure the
Polarizer in place.
3.
Re-assemble the common cover, ensuring that the housing and the cover
gasket are installed and not damaged and the cover oriented so the seam
in the cover gasket is pointing towards the radio’s Ethernet connectors,
using the 8 socket-head screws and washers removed earlier in Section
7.1.1.1
.
7.1.2
Replacing an Internal OMT—KM Series DT Only
7.1.2.1
Remove the OMT
Figure 7-4
Removing the OMT
1.
Remove the Common Cover—refer to Figure 7-1.
2.
Using an appropriate Allen key size, remove the 4 (6-32 x 1-1/4”) socket-
head screws attaching the OMT assembly. (Refer to Table 7-1 for screw
sizes).
3.
Ensure keeping all fasteners in a safe place for future use.
4.
Remove the OMT assembly.
OMT
OMT Socket-head screws (4)