The suitable positions are as follows:

The highest hole (tip) is for areas 25-35° latitude (inclination 25°)
The middle hole is for areas 30-40° latitude (inclination 30°)
The lowest hole for areas 35-50° latitude. (inclination 35°)

b) If however maximum efficiency is of no concern for the whole year and enhanced efficiency is
required  during  the  summer  (which  will  result  in  decreased  efficiency  during  the  winter)  move
the support points A (photo 2) one hole higher than the proper place which is described earlier.
This  can  be  applied  in  the  case  of  hotel  installations,  specifically  for  hotels  which  are  fully
booked during the summer and are either closed or have very few guests during the winter.

If  on  the  other  hand  enhanced  efficiency  is  required  during  the  winter  (resulting  in  decreased
efficiency during the summer) then the support points A are moved one hole below the proper
hole.

After adjusting the product’s inclination, the collector must have a south facing position if your
location is in the northern hemisphere or a north facing position if your location is in the southern
hemisphere.

Содержание ALPHA 3

Страница 1: ...GB INSTALLATION MANUAL USERS MANUAL INTEGRATED SOLAR WATER HEATER 3...

Страница 2: ...2...

Страница 3: ...must be moved further back so that the distance between the product and the obstacle is twice the height of the obstacle Photo 1 1 2 Unfold the supporting aluminum frames which are folded in the back...

Страница 4: ...e higher than the proper place which is described earlier This can be applied in the case of hotel installations specifically for hotels which are fully booked during the summer and are either closed...

Страница 5: ...bar pressure in order to allow the water to pass through A gate valve should also be connected to the cold water pipe so that the water supply can be shut off when necessary 2 2 A pipe with a red rub...

Страница 6: ...d properly to the ground of the building The electric heating element could be 1 5 2 0 3 0 or 4 0kW and contains a thermostat incorporated in it which has been fixed at 60 C at our factory If a differ...

Страница 7: ...s during the winter and 17 00 hours during the summer Maximum temperatures range from 60 C to 80 C depending on the season the product s inclination and provided we have not consumed any water earlier...

Страница 8: ...8 SOLE S A SOLAR DOMESTIC APPLIANCES MANUFACTURER Lefktron Laikon Agonon 136 71 Acharnai Athens Greece Tel 30210 2389500 Fax 30210 2389502 Email export sole gr www sole gr www eurostar solar com...