Packing List
Quick Installation Guide
Solax Box 3.0
Wi-Fi antenna x1
I
Battery Installation
BMU Installation
Wi-Fi connector x1
Quick Installation Guide x1
Warranty card x1
item
①
item
②
Expansion tubes x2
Expansion screws x2
M6 washers x2
item
③
item
④
item
⑤
Bracket x2
Battery Guard x1
item
⑥
item
⑦
item
⑧
BMS cable x1
item
⑨
Box Installation
-
Tighten
the
expansion
tubes.
-
Pass
the
expansion screws though the M6 washers,
then screw the expansion screws.
-
Place Solax Box 3.0 against the ground.
-
Drill holes with
φ
10 drill.
-
Depth: at least 50mm
Connectors inside the Box
+
-
-
Overview of connectors inside the Solax Box 3.0.
(Wiring of the connectors inside the box has been completed upon delivery.)
item
③
item
④
item
⑤
LG Connectors
X 2 pairs
BAT Connector
Pv1-
Pv1+
Pv2-
Pv2+
EPS Connector
AC Connector
+
-
Application
Application
Connectors
Connectors
Notes:
-
Affix the empty box on the wall rst before proceeding any installation. It will be too dangerous to move as the box tting with batteries and inverter will
overweigh box-handle’s bearing limit.
-
Clean or replace the ventilation lters every three months.
CAN/RS485
CAN2
CAN/RS485
CAN2
CAN/RS485
CAN2
CAN/RS485
CAN2
CAN2
SWITCH
-
Connect LG connectors
into the jacks on the battery.
For
one
battery
For
two
batteries
(in parallel)
-
Find
cable in
BMS
Solax
Box 3.0 packaging
.
-
Insert the “LG-Bat” side of
the “BMS” cable into the “CAN/
RS485" port on the battery
(The “Solax” side is to be related
to BMU in chapter V).
-
Find intra-rack network
cable in
battery packaging
.
-
Insert it into “CAN2" ports
on the batteries respectively.
-
Place the battery into the Solax Box 3.0.
-
Install the battery guard.
Solax Box 3.0 can be equipped with two models of batteries respectively.
M48063P3S
M48126P3S
Battary
Nominal
Voltage
Nominal
Capacity
Dimension
51.8V
51.8V
63Ah
126Ah
M48063P3S
445*110*338.8mm
445*110*586.6mm
M48126P3S
Nominal
Energy
3.262kWh
6.524kWh
Maximum
Current
63A
63A
CAN/RS485
CAN2
item
⑨
item
⑧
item
⑨
LG-Bat
LG-Bat
-
Insert the key.
-
Open the door.
-
If the space is too narrow to fully open the door, you are
able to remove the door. Please note that the door can only
be removed when opened 30 degrees or more.
-
Dismantle the ground wire before removing the door.
-
Remove the safety bezel.
30
°
Communication:
-
Find the BMS cable which has
been connected to the Battery
(chapter IV ).
-
Insert the “Solax” side of BMS
cable into the “BMS” port on the
BMU.
Battery Power Supply
:
-
Find BAT Connector inside the box (chapter III).
-
Insert BAT connector into “BAT” port on the
BMU.
-
Connection
between
BMU and
Battery
(Wiring of BMU side).
-
Match the BMU with bracket.
Communication
:
-
Find CAN connector in
BMU Packaging
.
-
Insert one side of the connector into “CAN”
port on the BMU (The other side is to be related
to SK
-
TL in chapter VI).
BUS
Connection:
-
Find BUS Connectors in
BMU Packaging
.
-
Connect
BUS connectors to “BUS” port on the
BMU (The other side is to be related to SK
-
TL in
chapter VI).
-
Connection
between
BMU and
SK-TL
(Wiring of BMU side).
BAT Connector
Sola
x
item
⑨
Corrugated Tubing x1
item
⑩