GAS CONVERSION
GAS CONVERSION LABEL INSTRUCTIONS
1. When converting this fireplace, use a permanent marker to complete the supplied gas conversion label then affix it to
the right side of fireplace above the control module as pictured below.
2. Affix the supplied rating plate conversion label to the rating plate. Be sure to not cover the Model and Gas Pressure
information for the model and fuel you are converting to. With a permanent marker, check off the fuel type you are
converting to.
MODEL NOS. BI-16N, BI-16P
VENTED GAS FIREPLACE HEATER
NOT FOR USE WITH SOLID FUEL.
SER. NO.
BI-16-
NATURAL GAS
PROPANE (LP) GAS
Input Rating-Btu/hr
Min. Input Rating-Btu/
hr Orifice - DMS
Manifold Pressure
Min. Supply Pressure
Max. Supply Pressure
Natural Gas
13,500
7,500
#53
4.8”wc/1.2kPa
5.5”wc/1.4kPa
10.0”wc/2.5kPa
Propane
13,500
7,500
#58
10.0”wc/2.5kPa
11.0”wc/2.8kPa
13.0”wc/3.3kPa
Debit Calorifique
Puissance
Minimum L’injector
Press. A la tubulure
Press. D’Arrivée
Min Press.
D’Arrivée Max
This product has been tested and listed by PFS TECO to ANSI
Z21.88-2016
·
CSA 2.33-2016 Vented Gas Fireplace Heaters and CSA
2.17-2017, Gas-Fired Appliances For Use At High Altitudes. This
appliance equipped only for alti-tudes from 0-2000 feet (0-610m). In
Canada 0-4500 feet (0-1370m).
This appliance must be installed in accordance with local codes, if any;
If none follow the
National Fuel Gas Code
,
ANSI Z223.1/NFPA 54,
of
Natural Gas and Propane installation Codes,
CSA-B149.1.
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION:
0” (0mm)
0” (0mm)
0” (0mm)
0” (0mm)
0” (0mm)
Fireplace Surround to L. Side Wall
Fireplace Surround to R. Side Wall
Fireplace Surround to Corner Wall
Fireplace Surround to Ceiling Wall
Fireplace Surround to Rear Wall
Fireplace Surround to Floor
0” (0mm)
*The minimum required clearance to be maintained from the fireplace to
combustible flooring is measured from the top surface of carpeting, tile, etc.
SUPPLIED COOL ZONE KIT MUST BE INSTALLED.
CAUTION:
Do not operate the
appliance with glass doors removed, cracked
or broken. Replacement of the glass panel(s)
should be done by a licensed or qualified
service person. See the Owner’s Manual for
more information.
WARNING: Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to the owner’s
information manual provided with
this appliance. For assistance or additional
information, consult a qualified installer, service agency or the gas supplier.
CAUTION:
Label all wires prior to
disconnection when servicing. Wiring errors
can cause improper and dangerous
operation. Verify proper operation after
servicing.
Keep burner and control compartments clean. See installation and operating
instructions accompanying appliance.
This vented gas fireplace is not for use with air filters.
This appliance is only for use only with the type of gas indicated on the
rating plate and may be installed in an aftermarket, permanently located,
manufactured home (USA only) or mobile home, where not prohibited by
local codes. See Owner’s Manual for details.
This appliance is not convertible for use with other gases, unless a
certified conversion kit is used.
This appliance must be properly connected to a Direct Vent, venting
system in accordance with the manufacturer’s installation instructions.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY.
CAUTION:
HOT WHILE IN OPERA-
TION. DO NOT TOUCH, SEVERE BURNS MAY
RESULT. KEEP CHILDREN, CLOTHING, FUR-
NITURE, GASOLINE AND OTHER LIQUIDS
HAVING FLAMMABLE VAPORS AWAY.
MANUFACTURED BY:
Progressive Manufacturing Inc.
452 Sunapee Street
Newport, NH 03773
USA
Rpt. # F19-217
THIS APPLIANCE IS EQUIPPED FOR:
SÓLAS – DIRECT VENT GAS FIREPLACES
This Fireplace
has been
converted.
See conversion
label in fireplace.
This Fireplace
has been
converted.
See conversion
label in fireplace.