The following tables show for each installation situation:
•
the way of fastening (screws, clamps, insertion system)
•
the frame areas, approved for fastening
•
the maximum permitted pressure load on the modules
Information on the tightening torque can be found in the documentation of the clamp manufactu-
rer. Fastenings must not deform the solar modules. Clamps must not touch the front glass.
Screws
Module clamps
areas approved for fastening
substructure
Only use the holes (long hole 14 x 9 mm) provided in the frame!
Min. clamp surface area: 8 x 40 mm
8
6
0
245
245
245
245
Max. permitted pressure load to the module: 2.400 N/m²
Max. permitted pressure load to the module: 2.400 N/m²
Module clamps
Insertion system
areas approved for fastening
substructure
Min. clamp surface area: 8 x 40 mm
2
55
2
55
2
55
2
55
20
5
Max. permitted pressure load to the module: 2.400 N/m²
Max. permitted pressure load to the module: 2.400 N/m²
PAGE 16 | SUBJECT TO CHANGE | © 2019 SOLARWATT GMBH | AZ-TM-PMS-1584 | REV 001 | STATUS: 01/2019