background image

The following tables show for each installation situation:

• 

the way of fastening (screws, clamps, insertion system)

• 

the frame areas, approved for fastening

• 

the maximum permitted pressure load on the modules

Information on the tightening torque can be found in the documentation of the clamp manufactu-
rer. Fastenings must not deform the solar modules. Clamps must not touch the front glass.

Screws

Module clamps

areas approved for fastening

substructure

Only use the holes (long hole 14 x 9 mm) provided in the frame!

Min. clamp surface area: 8 x 40 mm

8

6

0

245

245

245

245

Max. permitted pressure load to the module: 2.400 N/m²

Max. permitted pressure load to the module: 2.400 N/m²

Module clamps

Insertion system

areas approved for fastening

substructure

Min. clamp surface area: 8 x 40 mm

2

55

2

55

2

55

2

55

20

5

Max. permitted pressure load to the module: 2.400 N/m²

Max. permitted pressure load to the module: 2.400 N/m²

PAGE 16 | SUBJECT TO CHANGE | © 2019 SOLARWATT GMBH | AZ-TM-PMS-1584 | REV 001 | STATUS: 01/2019

Содержание BLACK 60M STYLE

Страница 1: ...ng aerial systems EN 62305 Lightning protection EN 62446 Grid coupled photovoltaic systems IEC 60364 Erection of low voltage systems EXCLUSION OF LIABILITY The warranty terms available at www solarwat...

Страница 2: ...valid in the relevant country when plan ning setting up and operating grid connec ted PV systems For information on additional requirements please contact the responsible local authorities and the net...

Страница 3: ...ind and snow loads as well as the weight of the solar modules The instructions from the installation system manu facturer must also be complied with No mecha nical stresses from the actual building e...

Страница 4: ...dule heats up during operation Ensure that there is sufficient rear ventilation to avoid reductions in yield Also ensure that no flammable gases can escape or accumu late close by NOTE In regions with...

Страница 5: ...ws Module clamps areas approved for fastening substructure Only use the holes longhole14x9mm provided in the frame Min clamp surface area 8 x 40 mm 860 245 245 245 245 Max permitted pressure load to t...

Страница 6: ...module 3 600 N m It is not permitted to use SOLARWATT solar modules as overhead glazing For roof installati on these solar modules may only be installed over a fire resistant roof covering NOTE Additi...

Страница 7: ...aximum system voltage as listed in applicable data sheet The maximum num ber of solar modules installed parallel without string fuse is two Please comply with the value specified in the data sheet for...

Страница 8: ...g cable lug with ground cable Toothed locked washer Module frame with hole for grounding 4 0 mm Spring washer Nut It is advisable to install lightening protection in exposed locations The solar module...

Страница 9: ...ctive is nati onally oriented meaning that each EU Member State has its own legal regulations and practical handling for the sale and return of PV modules Contact us by e mail at info solarwatt com an...

Отзывы: