background image

Congratulations on the purchase of your SOLARWATT Solar Module

These  instructions  describe  the  assembly, 
connection, maintenance, and disposal of solar 
modules. Please read them carefully and com-
ply with them accordingly. 

The installation and electrical connection of 

photovoltaic  systems  may  only  be  carried  out 
by  specialist  personnel,  who  are  familiar  with 
this  work  through  their  professional  qualifica-
tions.  For  the  operation,  installation,  use  and 
maintenance of the other components, comply 
with the relevant installation instructions from 
the manufacturer.

Incorrect installation can cause damage to pro-
perty, which could consequently pose a risk to 
people.  SOLARWATT  accepts  no  responsibility 
or liability for losses, damage, or costs resulting 
from  incorrect  installation,  operation,  use,  or 
maintenance or losses, damage, or costs which 
are connected to any of the above in any way. 

The SOLARWATT installation instructions should 

be made available to the operator as part of the 
solar power system documentation and stored 
by the operator.

Failure to comply with the installation instructions results in the warranty and guaran-
tee becoming null and void.

WARNING

Comply  with  the  guidelines,  laws,  and  regula-
tions valid in the relevant country when plan-
ning,  setting  up,  and  operating  grid-connec-
ted  PV  systems.  For  information  on  additional 
requirements,  please  contact  the  responsible 

local authorities and the network operator.

Eco  modules  are  manufactured  according  to 
SOLARWATT  specifications.  The  modules  are 
TÜV Süd-tested and fulfill the requirements of 
the extended test standard IEC 61215, as well 
as the safety standard IEC 61730. In addition, 
the module deliveries are checked by our quali-
ty management according to a defined monito-
ring plan and additionally tested in our labora-
tory in Dresden for their quality and long-term 
reliability.
If treated correctly, your SOLARWATT solar mo-
dules will offer you several decades of service.

SOLARWATT  recommends  insuring  the  PV  sys-
tem  against  reduced  yields  or  damage  with 
 SOLARWATT  Full  Coverage  for  complete  secu-
rity. Further information is available from your 

SOLARWATT partner or online at  www.solarwatt.

com.

Information on the solar module

Detailed  electrical  and  mechanical  properties 
for your specific module type can be found on 
the relevant data sheet. The key technical data 
under  standard  test  conditions  [STC,  solar  cell 
temperature:  25°C,  irradiation:  1,000  Watt/m², 
air  mass:  1.5  (corresponds  to  a  sun  elevation 
angle of 41.8°)] can also be found on the name-
plate of the solar module.

SUBJECT TO CHANGE | © 2019 SOLARWATT GMBH | AZ-TM-PMS-1584 | REV 001 | STATUS: 01/2019 | PAGE 13

Содержание BLACK 60M STYLE

Страница 1: ...ng aerial systems EN 62305 Lightning protection EN 62446 Grid coupled photovoltaic systems IEC 60364 Erection of low voltage systems EXCLUSION OF LIABILITY The warranty terms available at www solarwat...

Страница 2: ...valid in the relevant country when plan ning setting up and operating grid connec ted PV systems For information on additional requirements please contact the responsible local authorities and the net...

Страница 3: ...ind and snow loads as well as the weight of the solar modules The instructions from the installation system manu facturer must also be complied with No mecha nical stresses from the actual building e...

Страница 4: ...dule heats up during operation Ensure that there is sufficient rear ventilation to avoid reductions in yield Also ensure that no flammable gases can escape or accumu late close by NOTE In regions with...

Страница 5: ...ws Module clamps areas approved for fastening substructure Only use the holes longhole14x9mm provided in the frame Min clamp surface area 8 x 40 mm 860 245 245 245 245 Max permitted pressure load to t...

Страница 6: ...module 3 600 N m It is not permitted to use SOLARWATT solar modules as overhead glazing For roof installati on these solar modules may only be installed over a fire resistant roof covering NOTE Additi...

Страница 7: ...aximum system voltage as listed in applicable data sheet The maximum num ber of solar modules installed parallel without string fuse is two Please comply with the value specified in the data sheet for...

Страница 8: ...g cable lug with ground cable Toothed locked washer Module frame with hole for grounding 4 0 mm Spring washer Nut It is advisable to install lightening protection in exposed locations The solar module...

Страница 9: ...ctive is nati onally oriented meaning that each EU Member State has its own legal regulations and practical handling for the sale and return of PV modules Contact us by e mail at info solarwatt com an...

Отзывы: