background image

SOLARWATT FRAMED GLASS-FOIL MODULES 

|

  INSTALLATION INSTRUCTIONS 

| EN

SOLARWATT
INSTALLATION INSTRUCTIONS

FOR FRAMED GLASS-FOIL MODULES

EU-STANDARDS

EUROCODE 1 (EN 1991-1)

 

Actions on structures

EN 13501 

 

Fire behavior of building materials and buil-

ding component
EN 60728-11

 

Setting up and operating (grounding) aerial 

systems
EN 62305

 

Lightning protection

EN 62446

 

Grid-coupled photovoltaic systems
IEC 60364

Erection of low-voltage systems

EXCLUSION OF LIABILITY

The warranty terms available at                                      

www.solarwatt.com apply.

You can check the current status of the instal

-

lation instructions at www.solarwatt.com.

Please find other languages at 

 

www.solarwatt.com.

The following directives and standards must be complied with when planning, setting up, and 
maintaining grid-connected PV systems:

ECO 60M

ECO 60M STYLE

Содержание BLACK 60M STYLE

Страница 1: ...ng aerial systems EN 62305 Lightning protection EN 62446 Grid coupled photovoltaic systems IEC 60364 Erection of low voltage systems EXCLUSION OF LIABILITY The warranty terms available at www solarwat...

Страница 2: ...valid in the relevant country when plan ning setting up and operating grid connec ted PV systems For information on additional requirements please contact the responsible local authorities and the net...

Страница 3: ...ind and snow loads as well as the weight of the solar modules The instructions from the installation system manu facturer must also be complied with No mecha nical stresses from the actual building e...

Страница 4: ...dule heats up during operation Ensure that there is sufficient rear ventilation to avoid reductions in yield Also ensure that no flammable gases can escape or accumu late close by NOTE In regions with...

Страница 5: ...ws Module clamps areas approved for fastening substructure Only use the holes longhole14x9mm provided in the frame Min clamp surface area 8 x 40 mm 860 245 245 245 245 Max permitted pressure load to t...

Страница 6: ...module 3 600 N m It is not permitted to use SOLARWATT solar modules as overhead glazing For roof installati on these solar modules may only be installed over a fire resistant roof covering NOTE Additi...

Страница 7: ...aximum system voltage as listed in applicable data sheet The maximum num ber of solar modules installed parallel without string fuse is two Please comply with the value specified in the data sheet for...

Страница 8: ...g cable lug with ground cable Toothed locked washer Module frame with hole for grounding 4 0 mm Spring washer Nut It is advisable to install lightening protection in exposed locations The solar module...

Страница 9: ...ctive is nati onally oriented meaning that each EU Member State has its own legal regulations and practical handling for the sale and return of PV modules Contact us by e mail at info solarwatt com an...