9
Notice!
If the expansion tank is filled above
the recommended level a loss of
heat may incur as a result of the self
circulation, and the space reserved
for fluid expansion will be reduced
3.4 Installing the expansion tank
Expansion Tank
Hot fluid from the
solar collector
Hot fluid to the hot water
cylinder.
The following tubing must
be placed underneath the
minimum level of fluid.
Cold fluid from the
hot water cylinder
Air inlet and outleton top
of expansion tank
Normal level of fluid.
Max level of fluid.
Minimum level of fluid.
Be carefull not to overfill the tank
extra fluid may be filled in here
Clear tube to control fluid level. Hide under
the collector when not in use. Put a lid on top
of this tube (with a tiny hole for the air)
The expansion unit has several purposes:
1)
to absorb the expansion of the fluid when hot
2)
To let out the air from the fluid
3)
can contain all fluid of the collector if it should
boil
4)
this protects the fluid from being damaged
5)
needs no maintenance
6)
runs without pressure