As well as the menu items shown in the above diagram, the ConfigProbe(s) menu also includes the 'Units' parameter. This defines the
Units Of Measure input readings from modules are converted to. Can be configured for MM, Inch or Mil. Note: Only 'MM' type input
modules are converted, AIMs (input types of Volts, Current or Temperature) will not be converted.
9.3.3 Probe Sub-menus
Each probe has a sub-menu containing information about its serial number, module type, status, scale etc.
Some have extra information and/or settings.
All module sub menu's include parameters for Scale and Offset as well as ReScale and ReOffset. Scale and Offset are read only and
report the scale / offset of the module (4-20mA AIM for instance would provide an offset of 4mA and a scale of 16mA).
The 'ReScale' and 'ReOffset' parameters can be used to adjust the reading to real-world values. For example the above AIM providing 4-
20mA could be modified to produce 0-100% by setting the ReOffset parameter to 0 and the ReScale parameter to 100.
Note1: Whenever a module is added, the ReScale and ReOffset parameters are reset to the module Scale and Offset.
Note2: LT modules have an unknown scale and will default to a scale of zero when added – the ReScale parameter therefore needs to
be configured before an LT type module can be used. The ACS will provide an on-screen warning message about this.
9.3.3.1 LTH Lasers
The LTH Lasers also include a setting for 'Level Cut Time' (parameter: LsrLvlCT). This can be configured from 0.1mS to 1 second.
See the Orbit LTH user leaflet for application details.
The Laser sampling rate is displayed in its sub-menu, but is fixed at 4kHz. For increased filtering, use the 'Averaging' setting in the
ConfigPR menu.
9.3.3.2 Modules supported externally only
Analogue Input Modules (AIM) and Linear Encoders (LE) modules are supported by the ACS, however they can only be included as
external modules on the network, the ACS is not available with an AIM or LE 'built-in'.
503110 - Orbit ACS Manual
Issue 9
25 of 63
Содержание AMETEK ORBIT ACS Series
Страница 1: ......
Страница 17: ...9 1 SI100 AND SI200 DISPLAYS 503110 Orbit ACS Manual Issue 9 17 of 63 ...
Страница 23: ...9 3 1 Top Level Menu 503110 Orbit ACS Manual Issue 9 23 of 63 ...
Страница 24: ...9 3 2 Configure Probe s 503110 Orbit ACS Manual Issue 9 24 of 63 ...
Страница 29: ...9 3 5 Peak Preset Limits and Misc Menu 503110 Orbit ACS Manual Issue 9 29 of 63 ...
Страница 30: ...9 3 6 Output Input and Communications Menu 503110 Orbit ACS Manual Issue 9 30 of 63 ...
Страница 47: ...15 5 ASCII CHARACTER SET Example ASCII A is HEX 41 503110 Orbit ACS Manual Issue 9 47 of 63 ...