![Solaronics SSTG Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/solaronics/sstg/sstg_installation-operation-and-maintenance-instructions-manual_1314011023.webp)
23
BASIC SYSTEM CONFIGURATIONS
•
Stainless steel tube and reflector components are designated with a “SR” suffix, i.e. “C9SR”.
•
A metal turbulator is always in the LAST 10-foot (3.0m) long tube section.
•
These are the recommended configurations for your heater. Contact the factory with any questions.
•
LEGEND:
L
: LP/Propane gas,
N
: Natural gas,
4
: Burner,
U
:
180° U-Bend.
STRAIGHT TUBE
HEATER COMPONENTS
Burner Size
MBTUH (kW)
Length
feet (m)
Series
Gas
Type
4
Combustion
Chamber
Heat Exchangers
Exhaust
End
40 (12)
10 (3.1)
A
N/L
4
C9
----
----
40 (12)
15 (4.6)
A
N/L
4
C9
----
H6
40 – 60 (12 – 18)
20 (6.1)
A
N/L
4
C2
----
H1
65 – 85 (19 – 25)
20 (6.1)
MB
N(L)
4
C2
----
H9(H1)
65 – 85 (19 – 25)
25 (7.6)
MB
N(L)
4
C2
H7
H9(H1)
65 – 100 (19 – 29)
30 (9.1)
B
N(L)
4
C2(C3)
H2
H5
105 – 130 (31 – 38)
30 (9.1)
MC
N - only
4
C2
H3
H1
65 – 100 (19 – 29)
35 (10.6)
B
N(L)
4
C2(C3)
H2 H6
H5
105 – 130 (31 – 38)
35 (10.6)
MC
N - only
4
C2
H3 H7
H1
65 – 100 (19 – 29)
40 (12.2)
B
N(L)
4
C2(C3)
H2 H2
H5
105 – 120 (31 – 35)
40 (12.2)
B
N/L
4
C2
H2 H2
H5
125 (37)
40 (12.2)
B
N - only
4
C2
H2 H2
H5
125 (37)
40 (12.2)
C
L - only
4
C2
H2 H2
H5
130 – 150 (38 – 44)
40 (12.2)
C
N/L
4
C2
H2 H2
H5
100 (29)
45 (13.7)
B
N(L)
4
C2(C3)
H2 H2 H6
H5
105 – 120 (31 – 35)
45 (13.7)
B
N/L
4
C2
H2 H2 H6
H5
125 (37)
45 (13.7)
B
N - only
4
C2
H2 H2 H6
H5
125 (37)
45 (13.7)
C
L - only
4
C2
H2 H2 H6
H5
130 – 150 (38 – 44)
45 (13.7)
C
N/L
4
C2
H2 H2 H6
H5
100 (29)
50 (15.2)
B
N(L)
4
C2(C3)
H2 H2 H2
H5
105 – 120 (31 – 35)
50 (15.2)
B
N/L
4
C2
H2 H2 H6
H5
125 (37)
50 (15.2)
B
N - only
4
C2
H2 H2 H6
H5
125 (37)
50 (15.2)
C
L - only
4
C2
H2 H2 H2
H5
130 – 200 (38 – 59)
50 (15.2)
C
N/L
4
C2
H2 H2 H2
H5
150 – 200 (44 – 59)
55 (16.8)
C
N/L
4
C2
H2 H2 H2 H6
H5
150 – 200 (44 – 59)
60 (18.3)
C
N/L
4
C2
H2 H2 H2 H2
H5
150 – 200 (44 – 59)
65 (19.9)
C
N/L
4
C2
H2 H2 H2 H2 H6
H5
150 – 200 (44 – 59)
70 (21.3)
C
N/L
4
C2
H2 H2 H2 H2 H2
H5
U-TUBE
HEATER COMPONENTS
Burner Size
MBTUH (kW)
Length
feet (m)
Series
Gas
Type
4
Combustion
Chamber
Heat Exchangers
Exhaust
End
40 (12)
15 (4.6)
A
N/L
4
C9
U
H6
40 – 60 (12 – 18)
20 (6.1)
A
N/L
4
C2
U
H1
65 – 85 (19 – 25)
20 (6.1)
MB
N(L)
4
C2
U
H9(H1)
65 – 100 (19 – 29)
30 (9.1)
B
N(L)
4
C2(C3)
H6 U H6
H5
105 – 130 (31 – 38)
30 (9.1)
MC
N - only
4
C2
H7
U
H7
H1
65 – 100 (19 – 29)
40 (12.2)
B
N(L)
4
C2(C3)
H2 U H2
H5
105 – 120 (31 – 35)
40 (12.2)
B
N/L
4
C2
H2 U H2
H5
125 (37)
40 (12.2)
B
N - only
4
C2
H2 U H2
H5
125 (37)
40 (12.2)
C
L - only
4
C2
H2 U H2
H5
130 – 150 (38 – 44)
40 (12.2)
C
N/L
4
C2
H2 U H2
H5
100 (29)
50 (15.2)
B
N(L)
4
C2(C3)
H2 H6 U H6 H2
H5
105 – 120 (31 – 35)
50 (15.2)
B
N/L
4
C2
H2 H6 U H6 H2
H5
125 (37)
50 (15.2)
B
N - only
4
C2
H2 H6 U H6 H2
H5
125 (37)
50 (15.2)
C
L - only
4
C2
H2 H6 U H6 H2
H5
130 – 200 (38 – 59)
50 (15.2)
C
N/L
4
C2
H2 H6 U H6 H2
H5
150 – 200 (44 – 59)
60 (18.3)
C
N/L
4
C2
H2 H2 U H2 H2
H5
150 – 200 (44 – 59)
70 (21.3)
C
N/L
4
C2
H2 H2 H6 U H6 H2 H2
H5
•
NOTE: MC series tubes are all
painted black
.
Содержание SSTG
Страница 22: ...22 THIS PAGE INTENTIONALLY LEFT BLANK...